08. Gabion wall house, Pawna, India
Baseline model - Daylighting analysis summary
From the daylighting analysis of UDI, sDA and ASE, the following values have been derived for the baseline model:
Advertisement
UDI Within [% Area] = 21.77, sDA = 23.43, ASE = 17.66% EUI breakdown analysis:
The existing EUI for the baseline model is 43.199 kBtu/sq.ft The type of HVAC system used is as follows:
DOAS HVAC: DOAS with Fan Coil Chiller with Central Air Source Heat Pump Design Explorer analysis:
Analysis graph of 100 iterations:
Sensitivity analysis:

Selection of top 3 iterations:

The selection of the top 3 iterations from the rest of the iterations was based on
obtaining higher UDI and sDA values and lower EUI and ASE values.

Proposed model - Daylighting analysis : Level 0
1. Across the board WWR West is the most sensitive parameter. 2. WWR East has a clearer influence in ASE. 3. Skylight Height has higher impact in UDI and sDA. 4. EUI is mainly affected by Wall U-value.
UDI below UDI within UDI above ASE sDA

Proposed model - Daylighting analysis : Level 1

Proposed model - Daylighting analysis : Level 2


UDI below UDI within UDI above ASE sDA
UDI below UDI within UDI above ASE
Proposed model - Daylighting analysis summary
From the daylighting analysis of UDI, sDA and ASE, the following values have been derived for the baseline model:
UDI Within [% Area] = 51.09, sDA = 55.35, ASE = 37.33% EUI breakdown analysis:
The existing EUI for the baseline model is 33.576 kBtu/sq.ft