THERMAL COMFORT AND SELF-REPORTED PRODUCTIVITY IN AN OFFICE WITH CEILING FANS IN THE TROPICS

Page 1

Search All of eScholarship

Open Access Publications from the University of California

This Series

Deposit Manage Submissions

UC Berkeley

Unit Home eScholarship

UC Berkeley

Visit our Website Center for Environmental Design Research

About

Center for the Built Environment

All CBE Paper Series

Indoor Environmental Quality (IEQ)

Share

Download PDF

Thermal comfort and self-reported productivity in an office with ceiling fans in the tropics 2018

Main Content

https://doi.org/10.1016/j.buildenv.2018.03.013

Metrics

Article Abstract 1 Introduction

Author(s): Lipczynska, Aleksandra; Schiavon, Stefano; Graham, Lindsay T

Published Web Location

Jump To

2 Methods 3 Results 4 Discussion

Author & Article Info

5 Conclusions

Abstract

Acknowledgments

Here we present a field study examining the impact of elevated room temperature and air movement on thermal comfort and selfreported productivity. This experiment was performed in three environmental conditions (one with a set-point of 23 °C—a typical set-point used in Singapore—and two elevated (up to 28 °C) room temperature conditions). Occupants had shared control of ceiling fans. The results show that the most comfortable thermal condition, with thermal sensation closest to neutral, is achieved at a room temperature of 26 °C with operating fans. Increasing the temperature set-point from 23 °C to 26 °C resulted in a significant increase in thermal acceptability (from 59% to 91%), and a 44 kWh/m2yr savings in electrical energy used for comfort cooling. We found that a room’s set-point temperature can be increased up to 27 °C without creating a negative impact when controllable air movement is provided compared to an environment with a set-point of 23 °C. Thermal satisfaction is significantly higher in spaces of 26 °C with operating fans, than when the room’s temperature is set at the typical 23 °C. Moreover, the relative humidity in the office is decreased from 62% (when the temperature was 23 °C) to 50% when the temperature was 27 °C. Occupant’s self-reported ability to concentrate, be alert, and ability to be productive was comparably high in all conditions. The results indicate that work performance is poorly correlated with room temperature, but increases with greater individual thermal satisfaction.

Main Content

View Larger

References Appendix – Questionnaire

Metrics Author & Article Info

Related Items Creating alliesthesia in cool environments using personal comfort systems He, Yingdong; Parkinson, Thomas; Arens, Edward; Zhang, Hui; Li, Nianping; ... An Examination of Range Effects When Evaluating Discomfort Due to Glare in Singaporean Buildings Kent, Michael; Jakubiec, JA

For improved accessibility of PDF content, download the file to your device.

Visual Task Difficulty and Temporal Influences in Glare Response Altomonte, Sergio; Kent, Michael G; Tregenza, Peter R; Wilson, Robin Overcooling of Offices Reveals Gender Inequity in Thermal Comfort Parkinson, Thomas; Schiavon, Stefano; de Dear, Richard; Brager, Gail Impacts of life satisfaction, job satisfaction and the Big Five personality traits on satisfaction with the indoor environment

Top

Powered by the California Digital Library Copyright © 2017 The Regents of the University of California

Home

Privacy Statement

About eScholarship

Site Policies

Campus Sites

Terms of Use

UC Open Access Policy

Admin Login

eScholarship Publishing

Help

Accessibility


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.