Velvære | Techical Spec Sheet | Cabins

Page 1


cabin a technical spec sheet

01 CONCRETE

• Driveway + entryway

» Exposed aggregate concrete finish

• Garage

» Concrete to receive epoxy finish with flake

02 MASONRY

• Exterior stone

» Full veneer tumbled stone

• Stone caps

» Quarry grade cap stone

03 METALS

• Exterior guardrails

» Mix of 3/8” metal panel guardrails and metal rails with mesh

04 CARPENTRY

• Stair structure

» Framed in stairs with a wooden framing structure

• Siding material

» 1x6 thermally modified clear vertical grain hemlock

» Pre-finished shiplap.

• Deck surface material

» 1x6 thermally modified Accoya® deck

» Pre-finished

05 THERMAL + MOISTURE

• Emulsion waterproofing with drainboard on tall foundation walls

• Exterior continuous 1” ROCKWOOL® Insulation

• Metal roofing

» Standing seam metal

• Flat roofing

» TPO roofing with ballast

• Metal siding

» Standing seam metal cladding

• Fascia material

» Two-step fascia made from bent metal + wood

• Soffit material

» 1x6 thermally modified clear vertical grain hemlock

» Pre-finished tongue + groove

06 DOORS + WINDOWS

• Entry door

» Masonite hinged wood

• Windows

» Sierra Pacific aluminum wood clad window systems

• Garage door

» Prefinished flush panel door with no windows

» “Steel finish”

• Cambridge elevating heritage elevator

cabin a technical spec sheet (cont.)

07 MECHANICAL WORK

• Snow melt in the driveway, entryway

• Single shower head with handheld in owner’s suite

• Single shower head in all other bathrooms

• Whole home water filtration system

08 HEATING + COOLING MECHANICAL

• Radiant heat in the garage

• Electric floor heat in bathroom tile floor locations.

• Forced air system

• Two-furnace/AC system

» One system to service the upper level.

» The second system is to service the primary + lower levels with a dampener to separate floor zones.

• Three total zones, each with Honeywell thermostats

• Air filtration connected to furnace

• ERV tied into forced air system

• Single humidifier tied into the forced air system

09 ELECTRICAL

• Lutron Rania D2 cans

• Lutron lighting control system with Palladium keypads

• Cabinetry strip lighting in the kitchen + owner’s suite

• Prewire for future Lutron Palladium shades at all windows

» Excluding wet locations

» Motorized shades not included

• Water sensors at wet locations + exterior door contacts for security system