Cannon Street Floor Plans

Page 1

S-01

Proposed Ground Floor Plan S-03

E-02 1

2

3

4

6

5

7

16,317

A 910 2,100

LEGEND

910 2,100

910 2,100

D-06

D-06

D-06

D-06

1,300

3,459

6,867

Bin Storage

Addressable Smoke Detector

4,424

152

3,913

SD

152

3,379

SD

339

SD 7,299

All party walls to be 60mins fire resistance

341 5,634

4,771

150

SD

RWP

A 910 2,100

!

provide fire protection to the timber frame structure during construction

1,306

910

1,395

2,120

910

3,140

910

3,590

910

1,125

Ventilation & extract to commercial units on the ground floor & basement to be tenant fit out works with details confirmed at the time.

SD

S-02 100

S-02

Addressable Heat Detector

Unit GA 62 m2

Fire Alarm Break Glass Unit

1,500 2,100

574

FD30S 900 2,100

B 0.4m2 permanent ventilation grill to be provided to lift lobby wall adjacent to bin store. Fire curtain to be installed to lift entrance door at ground floor linked to a smoke detector in the bin store

1,647

D-04

lift 151

1,975

125

165

1,799

FD30S

D-03

FD30S

115 930

service 710 2,100 riser EL

800 2,100

N

Fire alarm system to be designed, installed & commissioned in accordance with BS 5839-1 or for dwellings BS 5839-6 (Category of system L1 to L5)

574

C

E-04

C

Unit GC 56 m2

Unit GB 59 m2

E-03

15,433

340

B

Secondary lighting (emergency escape lighting) to comply with BS 5266-1 Code of practice for the emergency escape lighting of premises.

D-03

8,566

Stair terminates at ground floor level, access to basement via access hatch

8,532

meter cupboard

7,134

Stairs 710 2,100

FD30S

SD

All doors & gates on escape routes to be fitted with appropriate fastenings readily operated from the side approached by people making an escape. All escape routes to be distinctively & conspicuously marked by emergency exit signs of adequate size complying with BS 5499-1.

1,085

115

1,416

125

5,039

340

1,200

125

SD 3,997

152

SD

3,913

152

0

1

2

3

4

5

3,962

Main Entrance Commercial Unit

Commercial Unit

Commercial Unit

W-01b

W-01a

3,032 1,910

2,688 2,060

2,688 2,097

1,269

W-01a

22

20

118

20

850 2,100

D-01

340

EL

2,178

15,832

Exit signage to comply with BS 5499-1 2002

EXIT

100

1,094

1,197

D-05

1,851

100

Cycle Storage

D-02

HD

D

731

340

D

Sill 50

S-03

300 1,050

3,841

Sill -137

Sill -100

300 1,050

2,688

5

4

3

S-01

2

1

329

850

3,309

16,924

517

2,688

6

7

E-01

Proposed Ground Floor Plan Notes

Revision

Description

1:50

Date

Project Title

21-21A Cannon St

DO NOT SCALE FROM THIS DRAWING. ALL DIMENSIONS ARE TO BE CHECKED ON SITE BEFORE CONSTRUCTION COMMENCES. DAVID COX ARCHITECTS OWNS THE COPYRIGHT TO THIS DRAWING. IT SHALL NOT BE REPRODUCED, DISTRIBUTED OR OTHERWISE USED WITHOUT THE CONSENT OF THE COPYRIGHT OWNER, UNTIL PAYMENT HAS BEEN ACCEPTED BY THE OWNER SUCH CONSENT IS DEEMED NOT TO HAVE BEEN GIVEN. THIS DRAWING SHALL ONLY BE USED FOR THE PURPOSES FOR WHICH IT WAS PREPARED. DRAWINGS CARRIED OUT FOR THE PURPOSES OF PLANNING APPROVAL SHALL NOT BE USED FOR OBTAINING PRICES OR FOR CONSTRUCTION PURPOSES.

Client 1 Ribblesdale Place, Preston Lancashire, PR1 3NA

Tricord Developments Ltd

T 01772 821444 E office@davidcoxarchitects.co.uk www.davidcoxarchitects.co.uk

Drawing Title

Proposed Ground Floor Plan

Project Status

PLANNING PRELIMINARY FOR COMMENT ONLY TENDER CONSTRUCTION

Scale Paper Size Date Drawn by

1:50 A1 20/05/2020

Drawing No.

1869 | 4.03A


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.