PSI Protonentherapy Newsletter Nr. 24 (12/2021)

Page 1

Newsletter of the Center for Proton Therapy  ::  Paul Scherrer Institut  ::  December 2021  ::  # 24 :: page 1

SpotOn+

Center for Proton Therapy  ::  Paul Scherrer Institut  ::  # 24_12/2021

Dear Reader, It is my pleasure to introduce you this month’s last 2021 News-

treatment time with rescanning was only 30% in comparison to

70 GyRBE, with a fractional dose ranging from 1.8 to 3 Gy RBE.

the non-gated nominal plan.

The estimated 4 year local control and overall survival was 77%

The target modelling of uveal melanomas by the treatment and 85%, respectively. Not surprinsgly, gross total resection

letter. You may have seen the recent press release on the first planning system having the clips information has known limi-

was an independent prognostic factor for tumor control, so was

patient with locally advanced (stage III B) NSCLC treated with tation and it has always been the goal of PSI to introduce also the tumor extension restricted to bone. Interestingly, there PBS proton therapy (PT) within the framework of the RTOG 1308

non-invasive imaging techniques to better define the target was a suggestion of better tumor local control with hypofrac-

study (clinicaltrial.gov NCT 01993810). This study has been volume. This work has been published previously but one of tionation (i.e. 3 Gy RBE per fraction), although this did not reach activated by the two NRG centers, namely Kantonspital Aarau

our PhD student reports in this issue torsional eye movement statistical significance. As a result, for large unresected sacral

and PSI. This female smoker was particularly difficult to treat detection during patient positioning for proton therapy by chordoma we propose hypofractionation and may consider (delivering 70 GyRBE), as she had extensive nodal involvement measuring the pattern of iris rotations. Twenty consecutive hyperthermia as published by Tran et al. (mediastinal and supra clavicular) and the dose-constraints of patients were assessed, although one in 5 the evaluation was That being said, I hope that this newsletter was of interest to organs at risk in direct vicinity of the target volume were quite hindered by the inability of selecting a convenient region of you and I wish all a Merry Christmas and Happy New Year. challenging to adhere. But thanks to the conformality of protons, interest in the iris region due to eyelid occlusion or importantly

Hopefully 2022 will easier for the patients, care givers and the

the heart V30% was only 6.5 (dose constraint V30% < 50 in the undesired light reflection. For those patients that could be

general population.

protocol). Needless to say, treating a mobile tumor with a dy-

assessed, a good correlation was observed between the BEV

namic beam may lead to under dosage of the primary tumor x-rays standard images of the clip and the new algorithm. and/or overshooting of the target. To mitigate the likelihood of Lastly, Walser et al. reports the outcome of sacral chordoma

Sincerely, Prof. Damien C. Weber,

patients treated with protons, with (n=10; 17%) or without

Chairman Center for Proton Therapy,

(gated window: 30% exhale) with rescanning. The increase of (n=50; 83%) conventional photon therapy to a median dose of

Paul Scherrer Institute

this beam/tumor motion interplay effect, we used gated PT