Backer BHV

Page 32

MORE TECHNICAL DETAILS AT WWW.BACKER.EU

TERMINAL BOXES WITH THERMOSTAT AND/OR THERMAL CUT-OFFS K11/K12

K13 150

130

204

94

204

94

TYPE

DESIGNED FOR

THERMOSTAT

BREAKING CAPACITY A/V

THERMAL CUT-OFF PART

BREAKING- CAPACITY A/V

ARTICLE NO.

K11A

2’’

2-pole 30-90°C

16/400

3-pole 110°C

20/400

1120 332 701

K12A

2’’

1-pole 30-90°C

16/400

3-pole 110°C

20/400

1120 332 801

K13A

2’’

-

3-pole 110°C

20/400

1120 332 901

K13A

2’’

-

3-pole

65°C

20/400

1120 332 905

K15A

2’’

2-pole

3-pole

65°C

20/400

1120 391 801

0-50°C

16/400

K31A If mounting on 2'' plugs assermbly kit 103.4 115.4

1150710301 shall be used.

90

90 118

TYPE

DESIGNED FOR

BREAKING CAPACITY A/V

THEMOSTAT PART

THERMAL CUT-OFF PART

K31A

1 ½-2''

20/400

3-pole 25-85°C

3-pole 110°C

ARTICLE NO. 1150 666

Assembly kit 2''

1150 710 301

K7E

Terminal box with electronic controller.

95

User-friendly with push buttons for desired

92

LED display for monitoring setpoints, process value and setup. K7E fits our element heads

115

setpoint and hysteresis.

from 1¼” to 2½”. K7E is designed to operate stand-alone or with other external control systems. TYPE K7E

32

SUPPLY VOLTAGE

POWER RANGE OF HEATING UNITS USED

230 VAC +N or 3x400 VAC +N

From 1000 W to12000 W is adjustable 1- 10°C

MEASUREMENT RANGE

SETPOINT RANGE

-45°C - 195°C

Phone. +46 451 661 00 · Fax. +46 451 661 95 · info@backer.se

5°C - 90°C

ARTICLE NO. 1151409701


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.