Magnet wire

Page 1

Magnet Wire Hermincel 200°C

Description HERMINCEL is the generic name of multipurpose Magnet Wire produced based on polyester (Amide-Imide) insulation overcoated with polyamideimide. This wire has excellent dielectric and thermal characteristics of resins based on polyester (Amide-Imide) and the advantages of chemical structure of polyamideimide. This wire is manufactured in two insulation thickness Single Film (HS) and Heavy (HD), combination of two resins one as base insulation and the other as overcoat. Wires shape can be round, squared or rectangular.

Thermal Class HERMINCEL Magnet Wires of CENTELSA are designed for a Thermal Class of 200°C.

Characteristics • Thermal stability for a 200°C operation. • High resistance to overloads. • Easy winding. • Resistance to Freon 12 y 22 used in refrigeration motors and compressors. • High resistance to abrasion. • High dielectric strength even in presence of humidity. • High resistance to Heat Shock. • High resistance to thermoplastic flow. 6


• Solvents resistance. • Properties are maintained in oil presence.

Aplications HERMINCEL Magnet Wires are used in a wide range of applications: automotive use as generators, alternators, field windings and starting motors; electronic use as coils, choke flyback TV; in special transformers as ballasts for mercury lamps; in distributions transformers, power transformers; low power motors and open small motors, hermetically closed, refrigeration and starting coils and for motors in general.

Standards and Specifications HERMINCEL Magnet Wires CENTELSA are manufactured under the following standards: NEMA MW-1000 35C, NTC 361 35C. Round Magnet Wire. NEMA MW-1000 36C, NTC 361 36C. Squared and rectangular Magnet Wire.

Certifications HERMINCEL Magnet Wires CENTELSA are certified by: UL NEMA MW-1000 35C. File E176676. Round Heavy Film Magnet Wire. UL NEMA MW-1000 36C. File E176676. Squared and rectangular Heavy Film Magnet Wire. ICONTEC (Colombia). Standard NTC 361. ICONTEC (Colombia). Quality Declared NEMA MW-1000 1997. FONDONORMA (Venezuela). NORVEN 366 (Standard COVENIN 3484).

Sizes Round Wire: Single Film 14 to 40 AWG. Heavy Film 8 to 40 AWG. Squared Wire: 4 AWG to 10 AWG. Rectangular Wire: See Graphic Size of rectangular wire.

Note: Other configurations and sizes not specified herein are available upon request. 7


Magnet Wire Hermincel 200°C Typical properties (18 AWG HD Type)

TEST

DESCRIPTION

REQUIREMENT

TiPICAL VALUE

Dimensions

External Diameter 4 point measured separated 45°C

1,110 mm Maximum

Elongation

Gradual elongation at rupture

32% Minimum

40%

Adherence & Flexibility

20% elongation and wrapped around a mandrel 3 times of nominal bare diameter.

No cracks visible in the film coating

Pass

Abrasion Resistance

Unidirectional (by NEMA)

1150g Mínimum average

1800

Ductility

Springback Test

58° Maximum

Heat Shock

20% elongation and wrapped around a mandrel 3 times of nominal bare diameter and heated 30 min. at 220°C.

SNo cracks visible in the film coating

Pass

Thermoplastic Flow

2000 g load (by NEMA)

300°C Minimu

360°C

Solubility

10 minutes preheated at 150°C and inmersed at 60°C in Butyl Cello solve and Xylene

No soften sufficiently to expose the bare conductor

Pass

Dielectric Strength Continuity Dielectric Strength at Nominal Temperature

5700 V NEMA Method Faults in 30.48 m

5 Maximum 4275 V

NEMA Method Note: Results obtained at CENTELSA’s Laboratories according to NEMA MW 1000 and NTC 361.

8

1,102 mm

36°

9000 V 0 7500 V


Magnet Wire Soldincel 200°C

Description SOLDINCEL is the generic name of this Magnet Wire produced based on polyurethane insulation overcoated with polyamideimide, its main characteristic is its almost instantaneous solder ability. This round wire is manufactured in two insulation thickness Single Film (SSN) and Heavy Film (SDN), this product is manufactured upon special requirement.

Thermal Class SOLDINCEL Magnet Wires of CENTELSA are designed for a Thermal Class of 155°C.

Characteristics • Easy winding. • High resistance to thermoplastic flow. • Solvents resistance. • Compatibility with varnishes. • Solder able without previous removal of film. • Excellent dielectric characteristics. • Excellent solder ability. • Insulation sublimates from 360°C to 430°C. • Abrasion resistant.

Applications SOLDINCEL Magnet Wires are used in a wide range of applications: automotive use as generators, alternators, field windings and starting motors; electronic use as coils, choke flyback TV; in different windings of radio frequency, special transformers as ballasts, startings, measurement windings, small transformers, small devices and controls, low power motors and open small motors. 9


Standards and Specifications SOLDINCEL Magnet Wires CENTELSA are manufactured under the following standards: NEMA MW-1000 80C, NTC 361 80C. Round Magnet Wire, Class 155째C.

Certifications SOLDINCEL Magnet Wires CENTELSA are certified by: UL NEMA MW-1000 80C. File E176676. Round Heavy Film Magnet Wire 155째C ICONTEC (Colombia). Standard NTC 361. ICONTEC (Colombia). Quality Declared NEMA MW-1000 1997.

Sizes Round Wire: 14 to 40 AWG.

Note: Other configurations and sizes not specified herein are available upon request.

10


Magnet Wire Soldincel 200°C Typical properties (18 AWG SDN Type)

TEST

DESCRIPTION

REQUIREMENT

TIPICAL VALUE

Dimensions

External diameter 4 points measured separated 45°C

1,110 mm Maximum

1,100 mm

Elongation

Gradual elongation at rupture

32% Minimum

39%

Adherence & Flexibility

20% elongation and wrapped around a mandrel 3 times of nominal bare diameter

No cracks visible in the film coating

Pass

Abrasion Resistance

Unidirectional (By NEMA)

1150 g Minimum average

1800

Ductility

Springback test

58° Maximum

Heat shock

20% elongation and wrapped around a mandrel 3 times of nominal bare diameter and heated 30 minutes at 220°C

No cracks visible in the film coating

Pass

Termoplastic flow

2000 g load (by NEMA)

200°C Minimum

250°C

Solubility

10 minutes preheated at 150°C and inmersed 30 minutes at 60°C in Xylene

No soften sufficiently to expose the bare conductor

Pass

Solderability

10 seconds at 430°C

Continuos covering welding

Pass

Dielectric strength

NEMA method

5125 V

Continuity

Faults in 30.48 m

5 Maximum

Dielectric strength at nominal temperature

NEMA method

3825 V

36°

8100 V 0 5300 V

Note: Results obtained at CENTELSA’s Laboratories according to NEMA MW 1000 and NTC 361.

11


Paper Insulated Magnet Wire

Construction Bare or enameled copper wires, round, squared or rectangular, covered with one ore more layers of dielectric paper applied helically and overlapped up to 50% according to specification. Twin flat wire are also produced, two paper insulated flat or rectangular wires paralleled and additionally covered with one or more layers of paper.

Thermal Class Paper Insulated Magnet Wires of CENTELSA are designed for a Thermal Class of 90°C dry or 105° oil impregnated.

Characteristics • Cellulosic paper thermally stabilized (Insuldur) • Insulation Dielectric Strength: 7.0 kV/mm (272 V/mil) • Insulation Thickness: one or more paper layers with different thicknesses (50 to 200 •m) helically and up to 50% overlapped, to get total required thickness. • The mechanical properties of this Magnet Wire make it resistant to the 12


vibrations of the equipment where they are used. Being material hygroscopic, they admit impregnating as oils of transformer or varnishes and increase the thermal class up to 105° C. • When choosing the section of a flat wire or rectangular wire is due to consider that winding square or almost square conductors, these tend to turn on their own axis and to lean on one of its edges. If the section is great, the flat wire is very difficult to straighten and it is even a hardening of the metal is obtained, producing additional winding difficulties. • In order to avoid this disadvantage, it is recommended to choose flat wire sections in which the thickness is at the most 2/3 of the wide one.

Applications The Insulated Wires Magneto with Paper are used in power and distribution transformers, dry or oil impregnated.

Sizes Round Wire: 2.5 to 12.5 mm. Squared Wire: 10 to 4 AWG Flat Wire: See Graph Ranges of Manufacture Flat Wire.

Note: Other configurations and sizes not specified herein are available upon request.

13


Round Magnet Wires (International Units) Manufacturing Standards: NEMA MW-1000 NTC 361 SINGLE FILM1

BARE WIRE SIZE AWG

6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

DOUBLE FILM (HEAVY FILM)

APPROX. MINIMUM MAXIMUM APPROX. MINIMUM MAXIMUM APPROX. SECTION WEIGTH INCREMENT DIAMETER WEIGTH INCREMENT DIAMETER WEIGTH 2 (mm ) MINIMUM NOMINAL MAXIMUM (kg/km) (mm) (mm) (kg/km) (mm) (mm) (kg/km) DIAMETER (mm)

4.074 3.630 3.231 2.878 2.563 2.281 2.032 1.811 1.613 1.435 1.278 1.138 1.013 0.902 0.805 0.716 0.635 0.569 0.505 0.450 0.399 0.358 0.318 0.284 0.251 0.224 0.201 0.178 0.157 0.140 0.124 0.112 0.099 0.086 0.076

4.115 3.665 3.264 2.906 2.588 2.304 2.052 1.829 1.628 1.450 1.290 1.151 1.024 0.912 0.813 0.724 0.643 0.574 0.511 0.455 0.404 0.361 0.320 0.287 0.254 0.226 0.203 0.180 0.160 0.142 0.127 0.114 0.102 0.089 0.079

4.135 3.683 3.282 2.921 2.601 2.316 2.062 1.839 1.636 1.458 1.298 1.156 1.029 0.917 0.818 0.726 0.645 0.577 0.513 0.457 0.406 0.363 0.323 0.290 0.257 0.229 0.206 0.183 0.163 0.145 0.130 0.117 0.104 0.091 0.081

13.30 10.55 8.37 6.63 5.26 4.17 3.31 2.63 2.08 1.65 1.31 1.04 0.824 0.653 0.519 0.412 0.325 0.259 0.205 0.163 0.128 0.102 0.0804 0.0647 0.0507 0.0401 0.0324 0.0254 0.0201 0.0158 0.0127 0.0102 0.00817 0.00622 0.00490

118.23 93.79 74.39 58.96 46.76 37.06 29.40 23.36 18.51 14.68 11.62 9.250 7.321 5.807 4.615 3.660 2.887 2.300 1.823 1.445 1.140 0.9099 0.7150 0.5751 0.4505 0.3566 0.2877 0.2262 0.1787 0.1408 0.1126 0.09074 0.07264 0.05531 0.04358

0.041 0.038 0.036 0.036 0.033 0.030 0.030 0.028 0.028 0.025 0.025 0.023 0.023 0.020 0.020 0.018 0.018 0.015 0.015 0.013 0.013 0.010 0.010 0.008 0.008 0.005 0.005

1.692 1.509 1.349 1.207 1.077 0.963 0.861 0.770 0.686 0.617 0.551 0.493 0.439 0.396 0.356 0.320 0.284 0.254 0.231 0.206 0.183 0.163 0.147 0.132 0.119 0.104 0.094

18.69 14.83 11.75 9.354 7.409 5.884 4.680 3.715 2.932 2.342 1.856 1.473 1.164 0.9290 0.7340 0.5900 0.4630 0.3670 0.2970 0.2340 0.1850 0.1460 0.1160 0.09400 0.07400 0.05700 0.04500

0.089 0.086 0.084 0.081 0.079 0.076 0.074 0.071 0.081 0.076 0.074 0.071 0.066 0.064 0.058 0.056 0.053 0.051 0.048 0.046 0.043 0.041 0.041 0.038 0.036 0.033 0.030 0.028 0.025 0.023 0.020 0.020 0.018 0.015 0.015

4.244 3.787 3.383 3.020 2.695 2.408 2.151 1.923 1.732 1.547 1.384 1.240 1.110 0.993 0.892 0.798 0.714 0.643 0.577 0.516 0.462 0.417 0.373 0.338 0.302 0.274 0.249 0.224 0.198 0.178 0.160 0.145 0.130 0.114 0.102

119.2 94.6 75.1 59.6 47.3 37.5 29.8 23.7 18.83 14.95 11.85 9.440 7.482 5.947 4.732 3.760 2.970 2.375 1.883 1.496 1.184 0.9460 0.7480 0.6030 0.4740 0.3770 0.3050 0.2410 0.1900 0.1500 0.1200 0.09700 0.07700 0.05900 0.04600

MAXIMUM WINDING TENSION2 (kg)

79.5 63.1 50.0 39.7 31.5 24.9 19.8 15.7 12.4 9.87 7.82 6.22 4.92 3.91 3.10 2.46 1.94 1.55 1.23 0.972 0.767 0.612 0.481 0.387 0.303 0.240 0.194 0.152 0.120 0.0947 0.0758 0.0610 0.0489 0.0372 0.0293

Notes: 1. NEMA MW-1000 Standard specify Single Layer magnet wire for 14 AWG size and below. 2. Maximum winding tension to avoid wire strecht, based on a maximum strenth of 5.98 kg/mm2. 3. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity. 4. Current density based on 0.101 and 0.152 mm2/A for Thermal Class of 200°C and 155°C. 5. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

14

CURRENT DC DENSITY 4 (A) RESISTANCE THERMAL CLASS at 20°C 3 155°C 200°C (ohm/km)

1.296 1.634 2.060 2.599 3.278 4.135 5.213 6.562 8.283 10.44 13.19 16.57 20.93 26.39 33.21 41.88 53.09 66.63 84.07 106.0 134.5 168.4 214.4 266.5 340.3 429.8 532.7 677.5 857.5 1089 1361 1689 2110 2771 3517

87 131 69 104 55 83 44 65 35 52 27 41 22 33 17 26 14 21 11 16 8.6 13 6.8 10 5.4 8.1 4.3 6.4 3.4 5.1 2.7 4.1 2.1 3.2 1.7 2.6 1.3 2.0 1.1 1.6 0.84 1.3 0.67 1.0 0.53 0.79 0.43 0.64 0.33 0.50 0.26 0.40 0.21 0.32 0.17 0.25 0.13 0.20 0.10 0.16 0.083 0.13 0.068 0.10 0.053 0.080 0.041 0.061 0.032 0.048


Round Magnet Wires Manufacturing Standards: NEMA MW-1000 NTC 361 SINGLE FILM1

BARE WIRE SIZE AWG

6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

APPROX. SECTION WEIGTH (cmil) MINIMUM NOMINAL MAXIMUM (lb/1000 pies) DIAMETER (mils)

160.4 142.9 127.2 113.3 100.9 89.8 80.0 71.3 63.5 56.5 50.3 44.8 39.9 35.5 31.7 28.2 25.0 22.4 19.9 17.7 15.7 14.1 12.5 11.2 9.9 8.8 7.9 7.0 6.2 5.5 4.9 4.4 3.9 3.4 3.0

162.0 144.3 128.5 114.4 101.9 90.7 80.8 72.0 64.1 57.1 50.8 45.3 40.3 35.9 32.0 28.5 25.3 22.6 20.1 17.9 15.9 14.2 12.6 11.3 10.0 8.9 8.0 7.1 6.3 5.6 5.0 4.5 4.0 3.5 3.1

162.8 145.0 129.2 115.0 102.4 91.2 81.2 72.4 64.4 57.4 51.1 45.5 40.5 36.1 32.2 28.6 25.4 22.7 20.2 18.0 16.0 14.3 12.7 11.4 10.1 9.0 8.1 7.2 6.4 5.7 5.1 4.6 4.1 3.6 3.2

26244 20822 16512 13087 10384 8226 6529 5184 4109 3260 2581 2052 1624 1289 1024 812.3 640.1 510.8 404.0 320.4 252.8 201.6 158.8 127.7 100.0 79.21 64.00 50.41 39.69 31.36 25.00 20.25 16.00 12.25 9.610

79.46 63.03 49.99 39.63 31.43 24.91 19.76 15.70 12.44 9.866 7.809 6.216 4.920 3.903 3.101 2.460 1.940 1.546 1.225 0.9714 0.7659 0.6115 0.4805 0.3865 0.3027 0.2397 0.1934 0.1520 0.1201 0.0946 0.0757 0.0610 0.04882 0.03717 0.02928

DOUBLE FILM (HEAVY FILM)

MINIMUM MAXIMUM APPROX. MINIMUM MAXIMUM APPROX. INCREMENT DIAMETER WEIGTH INCREMENT DIAMETER WEIGTH (lb/kft) (lb/kft) (mils) (mils) (mils) (mils)

1.6 1.5 1.4 1.4 1.3 1.2 1.2 1.1 1.1 1.0 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2

66.6 59.4 53.1 47.5 42.4 37.9 33.9 30.3 27.0 24.3 21.7 19.4 17.3 15.6 14.0 12.6 11.2 10.0 9.1 8.1 7.2 6.4 5.8 5.2 4.7 4.1 3.7

12.56 9.966 7.897 6.286 4.979 3.954 3.145 2.497 1.970 1.574 1.247 0.9899 0.7823 0.6243 0.4933 0.3965 0.3112 0.2466 0.1996 0.1573 0.1243 0.09812 0.07796 0.06317 0.04973 0.03831 0.03024

3.5 3.4 3.3 3.2 3.1 3.0 2.9 2.8 3.2 3.0 2.9 2.8 2.6 2.5 2.3 2.2 2.1 2.0 1.9 1.8 1.7 1.6 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0.8 0.7 0.6 0.6

167.1 149.1 133.2 118.9 106.1 94.8 84.7 75.7 68.2 60.9 54.5 48.8 43.7 39.1 35.1 31.4 28.1 25.3 22.7 20.3 18.2 16.4 14.7 13.3 11.9 10.8 9.8 8.8 7.8 7.0 6.3 5.7 5.1 4.5 4.0

80.11 63.57 50.45 40.02 31.77 25.19 20.01 15.91 12.65 10.05 7.964 6.344 5.028 3.997 3.180 2.527 1.996 1.596 1.265 1.005 0.7957 0.6358 0.5027 0.4052 0.3185 0.2534 0.2050 0.1620 0.1277 0.1008 0.08065 0.06519 0.05175 0.03965 0.03091

MAXIMUM WINDING TENSION2 (lb/kft)

175 139 110 87.4 69.4 55.0 43.6 34.6 27.4 21.8 17.2 13.7 10.9 8.61 6.84 5.43 4.28 3.41 2.70 2.14 1.69 1.35 1.06 0.853 0.668 0.529 0.427 0.335 0.265 0.209 0.167 0.135 0.108 0.0820 0.0646

CURRENT DC DENSITY 4 (A) RESISTANCE THERMAL CLASS at 20°C 3 155°C 200°C (ohm/kft)

0.3951 0.4981 0.6280 0.7923 0.9990 1.260 1.589 2.000 2.525 3.182 4.021 5.051 6.381 8.044 10.12 12.76 16.18 20.31 25.62 32.32 40.99 51.34 65.34 81.23 103.7 131.0 162.4 206.5 261.4 331.8 414.8 514.8 643.1 844.7 1072

Notes: 1. NEMA MW-1000 Standard specify Single Layer magnet wire for 14 AWG size and below. 2. Maximum winding tension to avoid wire strecht, based on a maximum strenth of 8500 psi. 3. DC resistance calculated based on a 10.729 ohm-cmil/ft resistivity. 4. Current density based on 200 and 300 cmil/A for Thermal Class of 200°C and 155°C. 5. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

15

87 131 69 104 55 83 44 65 35 52 27 41 22 33 17 26 14 21 10.9 16 8.6 13 6.8 10.3 5.4 8.1 4.3 6.4 3.4 5.1 2.7 4.1 2.1 3.2 1.7 2.6 1.3 2.0 1.07 1.6 0.84 1.3 0.67 1.0 0.53 0.79 0.43 0.64 0.33 0.50 0.26 0.40 0.21 0.32 0.17 0.25 0.13 0.20 0.105 0.16 0.083 0.13 0.068 0.10 0.053 0.080 0.041 0.061 0.032 0.048


Squared Magnet Wires (International System Unit) Manufacturing Standards: NEMA MW-1000 NTC 361 BARE WIRE SIZE AWG

4 5 6 7 8 9 10 11 12 13 14

MINIMUM

NOMINAL

MAXIMUM

CORNES RADIUS1 (mm)

5.138 4.575 4.074 3.630 3.231 2.878 2.563 2.278 2.027 1.803 1.603

5.189 4.620 4.115 3.665 3.264 2.906 2.588 2.304 2.052 1.829 1.628

5.240 4.666 4.155 3.701 3.297 2.934 2.614 2.329 2.078 1.854 1.654

1.016 1.016 0.813 0.813 0.813 0.660 0.660 0.508 0.508 0.406 0.406

DIAMETER (mm)

DOUBLE FILM SECTION (mm2)

APPROX. WEIGTH (kg/km)

26.04 20.46 16.37 12.86 10.09 8.07 6.32 5.09 3.99 3.20 2.51

231.49 181.87 145.49 114.37 89.67 71.75 56.22 45.22 35.46 28.48 22.30

MINIMO MAXIMUM INCREMENT DIAMETER (mm) (mm)

0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.076 0.076

5.367 4.793 4.282 3.828 3.424 3.061 2.741 2.456 2.205 1.981 1.781

APPROX. WEIGTH (kg/km)

MAXIMUM WINDING TENSION2 (kg)

DC RESISTANCE at 20°C 3 (ohm/km)

233.05 183.22 146.68 115.40 90.56 72.54 56.91 45.84 36.01 28.98 22.74

156 122 97.9 76.9 60.3 48.3 37.8 30.4 23.9 19.2 15.0

0.8153 1.028 1.296 1.634 2.060 2.599 3.278 4.135 5.213 6.562 8.283

CURRENT DENSITY 4 (A) THERMAL CLASS 155°C

200°C

171 135 108 85 66 53 42 33 26 21 17

257 202 161 127 100 80 62 50 39 32 25

Notes: 1. NEMA MW-1000 Standard specify a tolerance of ±25%. 2. Maximum winding tension to avoid wire strecht, based on a maximum strenth of 5.98 kg/mm2. 3. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity. 4. Current density based on 0.101 and 0.152 mm2/A for Thermal Class of 200°C and 155°C. 5. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Squared Magnet Wires Manufacturing Standards: NEMA MW-1000 NTC 361 BARE WIRE SIZE AWG

4 5 6 7 8 9 10 11 12 13 14

MINIMUM

NOMINAL

MAXIMUM

CORNER RADIUS1 (mils)

202.3 180.1 160.4 142.9 127.2 113.3 100.9 89.7 79.8 71.0 63.1

204.3 181.9 162.0 144.3 128.5 114.4 101.9 90.7 80.8 72.0 64.1

206.3 183.7 163.6 145.7 129.8 115.5 102.9 91.7 81.8 73.0 65.1

40.0 40.0 32.0 32.0 32.0 26.0 26.0 20.0 20.0 16.0 16.0

DIAMETER (mils)

DOUBLE FILM SECTION (cmil)

APROXX. WEIGTH (lb/kft)

51391 40376 32299 25389 19906 15928 12480 10039 7873 6323 4951

155.57 122.23 97.78 76.86 60.26 48.22 37.78 30.39 23.83 19.14 14.99

MINIMUM MAXIMUM INCREMENT DIAMETER (mils) (mils)

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

211.3 188.7 168.6 150.7 134.8 120.5 107.9 96.7 86.8 78.0 70.1

APROXX. WEIGTH (lb/kft)

MÁXIMUM WINDING TENSION2 (lb)

DC RESISTANCE at 20°C 3 (ohm/kft)

156.62 123.13 98.57 77.55 60.86 48.75 38.24 30.81 24.20 19.47 15.28

343 270 216 170 133 106 83 67 53 42 33

0.2485 0.3135 0.3951 0.4981 0.6280 0.7923 0.9990 1.2604 1.5890 2.0001 2.5245

Notes: 1. NEMA MW-1000 Standard specify a tolerance of ±25%. 2. Maximum winding tension to avoid wire strecht, based on a maximum strenth of 8500 psi 3. DC resistance calculated based on a 10.729 ohm-cmil/ft resistivity. 4. Current density based on 200 and 300 cmil/A for Thermal Class of 200°C and 155°C. 5. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

16

CURRENT DENSITY 4 (A) THERMAL CLASS 155°C

200°C

171 135 108 85 66 53 42 33 26 21 17

257 202 161 127 100 80 62 50 39 32 25


Rectangular Bare Wires (International System Unit) Corner Radius Manufacturing Standards: NEMA MW-1000 NTC 361

(mm)

(mils)

0.64 0.71 0.79 0.89 0.99 1.12 1.24 1.40 1.60 1.80 2.01 2.24 2.49 2.79 3.15 3.56 3.99 4.50 5.00 5.59 6.30 7.11

25 28 31 35 39 44 49 55 63 71 79 88 98 110 124 140 157 177 197 220 248 280

63 67 71 75 79 83 88 93 98 104 110 118 124 132 140 148 157 167 177 187 197 209 220 236 248 264 280 295 315 335 354 374 394 417 441 465 492 520 551 591 630 669 709 748

THICKNESS

1.60 1.70 1.80 1.90 2.00 2.12 2.24 2.36 2.50 2.65 2.80 3.00 3.15 3.35 3.55 3.75 4.00 4.25 4.50 4.75 5.00 5.30 5.60 6.00 6.30 6.70 7.10 7.50 8.00 8.50 9.00 9.50 10.0 10.6 11.2 11.8 12.5 13.2 14.0 15.0 16.0 17.0 18.0 19.0

WIDTH (mils, mm)

ROUND EDGE

20 mils, 0.50 mm

26 mils, 0.67 mm

31 mils, 0.80 mm

(1) 39 mils, 1.00 mm (1)

Notes: 1. Range not specified by NEMA MW-1000. 2. NEMA MW-1000 Standard specify a tolerance of Âą25% for Corner Radius. 3. Data herein indicated are approximate and are subject to normal manufacturing tolerances.

Increment in dimensions due to film coating THICKNESS

WIDTH MINIMUM

MAXIMUM

MINIMUM

MAXIMUM

mils

mm

mils

mm

mils

mm

mils

mm

DOUBLE FILM

2.5

0.064

4.5

0.114

3.0

0.076

5.0

0.127

QUADRUPLE FILM

4.0

0.102

6.0

0.152

5.0

0.127

7.0

0.178

17

THICKNESS

(mils)

(mm)

25 28 31 35 39 44 49 55 63 71 79 88 98 110 124 140 157 177 197 220 248 280

0.64 0.71 0.79 0.89 0.99 1.12 1.24 1.40 1.60 1.80 2.01 2.24 2.49 2.79 3.15 3.56 3.99 4.50 5.00 5.59 6.30 7.11


Ranges

(International System Unit)

THICKNESS (mm) 9 8 7 6 5 4 3 2 1 0 2

3

4

5

6

7

8

9

10

11

12

13

14

15 16 WIDTH (mm)

560

600 640 WIDTH (mils)

ENAMELED PAPER INSULATED

(English System Unit)

THICKNESS (mils) 360 320 280 240 200 160 120 80 40 0 80

120

160

200

240

280

ENAMELED PAPER INSULATED

18

320

360

400

440

480

520


Packing data Cylindrical reel

B

A

C

D

E

A: External diameter B: Exterior Length C: Drum diameter D: Inner hole diameter E: Useful wide

DIMENSIONS REEL TYPE

C B A 12 6

MATERIAL

SIZES AWG

WOOD RECTANGULAR WOOD & SQUARE WOOD/PLASTIC PLASTIC 6-26 PLASTIC 24-40

A

B

C

D

APPROX. CAPACITY

E

APPROX. TARE

(mm)

(Inches)

(mm)

(Inches)

(mm)

(Inches)

(mm)

(Inches)

(mm)

(Inches)

(kg)

(pound)

(kg)

(pound)

750 600 600 305 152

29.5 23.6 23.6 12.0 6.0

300 390 220 190 108

11.8 15.4 8.7 7.5 4.3

360 360 360 152 90

14.2 14.2 14.2 6.0 3.5

50 50 50 32 20

2.0 2.0 2.0 1.3 0.8

260 350 180 160 90

10.2 13.8 7.1 6.3 3.5

300 200 100 35 5

661.5 441.0 220.5 77.2 11.0

12.0 10.0 9.0 1.5 0.3

26.5 22.1 19.8 3.3 0.7

19


Packing data Conical reel

B

A

C

F

D

G

E

A: External bottom diameter B: External length C: Bottom internal diameter D: Inner hole diameter E: Useful wide F: Top internal diameter G: External top diameter

DIMENSIONS REEL No.

8.5" 10"

MATERIAL

SIZES AWG

PLÁSTICO 20-35 PLÁSTICO 11-27

A

B

C

(mm)

(Inches) (mm)

(Inches) (mm)

235 280

9.3 11.0

9.7 13.4

245 340

20

165 180

D (Inches)

(mm)

6.5 7.1

35 35

E

(Inches) (mm)

1.4 1.4

225 300

F (Inches) (mm)

8.9 11.8

145 150

APPROX. CAPACITY

G

(Inches) (mm)

5.7 5.8

215 250

APPROX. TARE

(Inches)

(kg)

(pound)

(kg)

(pound)

8.5 10.0

18 40

39.7 88.2

0.9 1.7

2.0 3.7


Handling of the Magnet Wire In all the stages of manufacture of the Magnet Wires, CENTELSA applies a special process (lubricant) with the purpose of preserving the soft temper copper, so that the wire can be winded and be wound with facility and so that it remains in the adequate position in a coil, without backing down or unrolling. Additionally, the user must have precautions during the subsequent use of the wire to avoid that the work in cold hardens it, thus making its winding easier. In order to avoid the rigidity derived from the handling and to conserve the wire in good state, it is recommended to have presents the following points: 1. To avoid operations of rewinding.

2. To avoid great tensions in winding so that the wire does not stretch, because this is a form of work in cold that besides to modify the soft temper, reduces the diameter. It is recommended not to apply in any case, greater mechanical tensions for each size than the indicated ones.

3. To avoid all unnecessary bending of the wire when winding, trying to occupy the lesser possible number of pulleys or guides, the ones that in any case will have a diameter greater than the one of the wire heavier than uses in this device.

21


4. To store the spools in a right way, avoiding mistreat of the wire.

5. To place the spools in sites of approximate temperatures to 25째C and relative humidity of 60%. 25째C

60%

6. It is important to make rotation of the wires according to the date of reception.