Hydraulic Hose Hose I.D. (inches)

Hose O.D. (inches)

Max. Oper. Pressure (psi)

Min. Burst Pressure (psi)

Min. Bend Radius (inches)

FC474–04

.25

.59

5000

20000

4.00

.25

FC474–06

.38

.75

4000

16000

5.00

.35

FC474–08

.50

.88

3500

14000

7.00

.42

FC474–12

.75

1.22

2250

9000

9.50

.62

FC474–16

1.00

1.50

2000

8000

11.00

.90

1508–6

.38

.84

4500

18000

5.00

.46

1508–8

.50

.97

4000

16000

7.00

.52

1508–12

.75

1.23

3000

12000

9.50

.82

1508–16

1.00

1.56

3000

12000

11.00

1.25

1508–20

1.25

2.00

2500

10000

16.50

2.01

FC323–12

.75

1.20

3000

12000

9.50

.94

FC323–16

1.00

1.48

3000

12000

12.00

1.22

FC323–20

1.25

1.86

3000

12000

16.50

1.70

FC323–24

1.50

2.11

3000

12000

20.00

2.20

FC323–32

2.00

2.63

3000

12000

25.00

3.21

Hose

Part Number

Double wire braid Low temperature

FC474

Vacuum Service (in./Hg)

Wt. Per Ft. (lbs)

Construction: Synthetic rubber tube, double braid reinforcement, and synthetic rubber cover. Application: Hydraulic hose for fluid conveying applications in frigid environments. For use in arctic environments on construction equipment and other mobile applications. For more information on specific fluid applications and high temperature ratings, see pages 22-26. Operating Temperature Range: –67°F to +175°F (–55°C to +80°C). For complete Agency Listings: See page 20.

Four-light spiral wire SAE 100R9A

1508

Construction: Synthetic rubber tube, 4-light spiral wire reinforcement, synthetic rubber cover. Application: Hydraulic system service with petroleum and water base fluids, for general industrial service. For more information on specific fluid applications and high temperature ratings, see pages 22-26. Operating Temperature Range: –40°F to +212°F (–40°C to +100°C). For complete Agency Listings: See page 20.

Four spiral wire Exceeds performance requirements SAE 100R12 (–20), SAE 100R11 (–24, –32)

FC323

Construction: AQP elastomer tube, 4-spiral wire reinforcement and a blue AQP elastomer cover. Application: Hydraulic system service with petroleum, fire-resistant, and water base fluids, fuel, and lubricating systems. For more information on specific fluid applications and high temperature ratings, see pages 22-26. Operating Temperature Range: –40°F to +300°F (–40°C to +150°C). For complete Agency Listings: See page 20.

64