GENERAL FLOOR PLAN NOTES

1.VERIFY ALL EXISTING GLAZING AT STOREFRONTS AND GLAZED DOORS COMPLIES WITH CODE REQUIREMENTS.
2.PROVIDE 3/4” FIRE-RATED PLYWOOD (PAINTED) FLOOR TO 8’-0” AFF ON 5/8” GWB ON ALL EXPOSED WALLS.

3.VERIFY ALL EXISTING GLAZING AT STOREFRONTS AND GLAZED DOORS COMPLIES WITH CODE REQUIREMENTS.
4.IF A FIRE ALARM SYSTEM IS FOUND TO BE INSTALLED, IT MUST BE UPGRADED TO COMPLY WITH CODE OR COMPLETELY REMOVED.
GENERAL NOTES
1. CLEAN ALL GLAZING AND SURFACES OF INTERIOR TO REMAIN.
2. REPLACE GLAZING WHICH HAVE BROKEN SEALS.
3. INSPECT EXISTING ENCLOSURE (INSIDE AND OUT). REPAIR/REPLACE CONDITIONS NEEDING MAINTENANCE. REPLACE DAMAGED MATERIALS. REPAIR LEAKS AND RELATED DAMAGE. COORDINATE WITH BUILDING MANAGEMENT.
4. PROVIDE SELF-DRYING CEMENT-BASED FINISHING UNDERLAYMENT (ARDEX OR EQUAL) AT LOCATIONS WHERE GROUND FLOOR SLABS HAVE SEPARATED OR HAVE BEEN DISPLACED BY SETTLEMENT. FEATHER EDGES AS NEEDED AT ADJACENT SURFACES TO COMPLY WITH ADA REQUIREMENTS.
5. FURNITURE BY OTHERS.
6. ALL EXPOSED METAL STUDS ABOVE OR BELOW CEILINGS SHALL BE SQUARE, PLUMB, AND PARALLEL.

7. PROVIDE BLOCKING AS REQUIRED IN WALLS WHERE MILLWORK ABUTTS (TYPICAL).
8. INSULATE ALL EXPOSED PLUMBING PIPES.
9. IF A FIRE ALARM SYSTEM IS FOUND TO BE INSTALLED, IT MUST BE UPGRADED TO COMPLY WITH CODE OR COMPLETELY REMOVED.
10. CHALK LAYOUT ON GROUND FLOOR PRIOR TO CONSTRUCTION SO THAT ARCHITECT CAN VERIFY REQUIRED CLEARANCES.
Olert: CAP AND SEAL FLUSH TO FLOOR IN MANNER REQUIRED BY CODES ALL EXISTING FLOOR PENETRATIONS TO BE DISCONTINUED.
GENERAL NOTES
1. PRIME OR SEAL WOOD REQUIRED TO BE JOB PAINTED IMMEDIATELY UPON DELIVERY TO JOB. PRIME EDGES, ENDS, FACES, CUTOUTS, UNDERSIDES AND BACK SIDES OF SUCH WOOD, INCLUDING CABINETS, COUNTERS, SHELVING AND TRIM.






2. INSTALL ALL FINISHES IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS.





















































3. CHANGES OF LEVEL BETWEEN FLOORING MATERIALS SHALL BE 1/4”.












4. SUBMIT ALL MAINTENANCE INFORMATION ON CARPET, WALLCOVERING, OTHER FINISHES AND EQUIPMENT TO OWNER AND ARCHITECT AT PROJECT COMPLETION.










5. PAINT ALL NEW AND EXISTING FINISH GYPSUM WALLBOARD SURFACES AS REQUIRED IN THE FINISH SCHEDULE AND MATERIALS S CHEDULE AND IN ACCORDANCE WITH THE PAINTING PLAN NOTATIONS.










6. IN GENERAL, ALL PAINT BREAKS SHALL BE AT INSIDE OR OUTSIDE CORNERS.






















GENERAL NOTES
1.CONTRACTOR SHALL FIELD ALL DIMENSIONS AND CONDITIONS
2. CONTRACTOR SHALL NOTIFY INTERIOR DESIGNER OF ANY DISCREPANCIES AS SOON AS THEY ARE IDENTIFIED
3. ALL DIMENSIONS ARE TO CENTERLINE UNLESS OTHERWISE NOTED

1 FURNITURE PLANELECTRICAL, DATA & TELECOMMUNICATIONS


1/16" 1'-0"
2V 2D 2V 2D FL 2V 2D 2V 2D
GENERAL NOTES TV TV TV TV TV TV
2V 2D
NP NP
1.EXISTING PHONE, DATE THAT ARE NOT SHOWN ON DRAWINGS SHOULD BE DISCONNECTED AND REMOVED AND PATHED BY GC.


1. THIS DRAWING IS FOR DESIGN REFERENCE ONLY, SHOWING PLACEMENT OF LIGHT FIXTURES, CEILING GRIDS, DIFFUSERS, RETURNS, SPEAKERS, ETC. SEE ENGINEERING DOCUMENTATION FOR SPECIFICATION ISSUES.
2. VERIFY EXACT LOCATIONS OF PNEUMATIC TUBE PENETRATIONS WITH BANK EQUIPMENT MANUFACTURER. FINISH EDGES AROUND PENETRATIONS PER MANUFACTURER’S RECOMMENDATIONS.
3. COORDINATE CEILING GRID MAIN RUNNER LOCATIONWITH PNEUMATIC TUBE PENETRATIONS.
4. PROVIDE 2’-0” x 2’-0” SUSPENDED LAY-IN ACOUSTICAL CEILING TILE (TYP) SEE DETAIL ????? FOR CEILING TILE DETAIL.

5. LOCATION OF UNDERCABINET LIGHTING.
RECESSED EAE MOUNTED
RECESSED ROUND 48”
HI-PANEL LIGHT
LED STRIP LIGHTING FIXTURE
METRO LED PLATORM LIGHTING
KEYNOTES GENERAL FLOOR PLAN NOTES
1

ANNODIAZED ALUMINUM STOREFRONT (FRAME ONLY)
2
1” GLASS PANELS AT THIS ELEVATION
1. SEE SPECIFICATIONS FOR HARDWARE.
2. CONTRACTORSHALL VEIFY ALL FIELD MEASUREMENTS.
3. ALL METAL DOORFRAMES SHALL MATCH STOREFRONT COLOR.

4 INSTALL HOLLOW METAL DOOR FRAME & HARDWARE - TO BE SUPPLIED
5. BY OTHERS INSTALLED BY CONTRACTOR
GENERAL FLOOR PLAN NOTES
1. TYPE "X" GYP WALL BOARD SPECIFIED THROUGHOUT UNLESS OTHERWISE SPECIFIED. PROVIDE TILE BACKER BOARD ON ALL WALLS WITH TILE.

2. CONFORM TO DETAILED REQUIREMENTS OF DESIGNATED TESTING AUTHORITY NUMBERS AT ALL WALLS. WALLS DESIGNATED AS "BASED ON" VARY AS NOTED IN PARENTHESIS. SEE STRUCTURAL SHEAR WALLS SCHEDULE FOR SHEAR WALL ATTACHMENT AND EDGE BLOCKING REQUIREMENTS WHERE APPLICABLE. STRUC SHEAR WALL SCHEDULE OVERRIDES LISTED ASSEMBLY ATTACHMENT AND BLOCKING REQUIREMENTS ONLY WHEN MORE RESTRICTIVE.
3. WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY IN STUD SIZE. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P.9 ITEM 16, "GREATER STUD SIZES (DEPTHS) SHALL BE PERMITTED TO BE USED IN METALOR WOOD-STUD SYSTEMS." THESE WALLS CAN ALSO BE SHOWN TO MEET THE REQUIRED FIRE RESISTIVE RATING BY THE CALCULATION METHOD PER SECTION 703.3.3 AND SECTION 721 IF REQUESTED.
4. WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY DUE TO THE ADDITION OF EXTRA LAYER(S) OF ELEMENTS. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P.9 ITEM 22, "ADDITIONAL LAYERS OF TYPE "X" OR REGULAR GYP BOARD SHALL BE PERMITTED TO BE ADDED TO ANY SYSTEM." FASTENERS SPECIFIED FOR THE ATTACHMENT OF GYP BOARD APPLIED OVER THE ADDITIONAL LAYER(S) OF ELEMENTS SHALL BE INCREASED BY NOT LESS THAN THE THICKNESS OF THE ADDITIONAL LAYER(S).
DETAIL NOTES - HEAD OF SHAFT WALLJ2131 R1
1USG SHEETROCK® BRAND GYPSUM LINER
2USG SHEETROCK® BRAND FIRECODE® X PANELS
3 COMPLETELY FILL GAP ABOVE GYPSUM PANELS WITH USG SHEETROCK® BRAND ACOUSTICAL OR SMOKE-SOUND SEALANT
4STRUCTURAL SLAB
5 USG SHEETROCK® BRAND FIRECODE® X PANELS CUT 5/8" FROM TOP OF PARTITION MAX
6J-RUNNER
8 USG SHEETROCK® BRAND GYPSUM LINER PANELS, CUT TOP OF PANEL 1" LESS THAN FLOOR-TO-CEILING HEIGHT
9Z-CLIPS
10STEEL BEAM WITH FIRE PROOFING
11STEEL PLATE
12STEEL STRAP 2"
13MINERAL WOOL INSULATION
14UNDERSIDE OF STRUCTURAL SLAB
15CONTINUOUS 20 GAUGE ANGLE
16 USG SHEETROCK® BRAND FIRECODE® X PANELS CUT 5/8" FROM UNDERSIDE OF PROTECTED STEEL PLATE
17 USG SHEETROCK® BRAND FIRECODE® X PANELS CUT 5/8 MAX. LESS FLOOR-TO-BEAM HEIGHT
18 USG SHEETROCK® BRAND FIRECODE® X PANELS
INSTALL FLUSH TO UNDERSIDE OF STRUCTURAL SLAB


GENERAL NOTES
1. CONTRACTOR TO SUMBIT SHOP DRAWINGS OF ALL CASEWORK FOR REVIEW BY INTERIOR DESIGNER PRIOR TO FABRICATION


2. CONTRACTOR TO FIELD VERIFY ALL CASEWORK DIMENSIONS
3. ALL INTERIOR BADINET SURFACES AND DRAWER INTERIORS TO BE CONVERTED WITH WHITE VINYL LINER
PT1PT1-
2 WORKROOM WD1RB1PT1PT1PT1PT1ACT1
3 MEETING ROOMWD1RB1PT1PT1PT1PT1ACT1
4 MEETING ROOMWD1RB1PT1PT1PT1PT1ACT1
5 TEAM ROOM WD1RB1PT1PT1PT1PT1ACT1
6 COPY & PRINTINGWD1RB1PT1PT1PT1PT1ACT1
7 MAIL ROOM WD1RB1PT1PT1PT1PT1ACT1
8 CLIENT PRESENTATION ROOM
CPT1RB1- - PT1PT1ACT1
9 MEETING ROOM CPT1RB1PT1- - PT1ACT1
10PRINCIPLES & ASSOCIATES CPT1RB1- PT1- PT1ACT1


11TECH SUPPORTCPT1RB1- PT1PT1PT1ACT1

12KITCHEN & STAFF AREA T1RB1PT1- PT1- ACT1
13MATERIALS LIBRARY CPT1RB1- - PT1WD1ACT1
14TEAM ROOM CPT1RB1- - WD1PT1ACT1