WORK SET EXAMPLE: UNUM RESIDENTIAL

Page 1

ARCHITECT

TT

IR

24025 HWY 120 GROVELAND, CA 95321

OA D

• • • • •

ARCHITECTURAL SITE 7AS-100 SITE PLAN

ARCHITECTURAL 7A-100 FOUNDATION PLAN 7A-101 1ST FLOOR & BASEMENT OVERALL PLAN 7A-102 2ND FLOOR OVERALL PLAN 7A-111 OVERALL ROOF PLAN 7A-200 EXTERIOR ELEVATIONS 7A-201 EXTERIOR ELEVATIONS 7A-300 BUILDING SECTIONS 7A-401 1ST FLOOR OVERALL RCP 7A-402 2ND FLOOR OVERALL RCP 7A-500 ENLARGED KITCHEN PLAN, RCP, & ELEVATIONS 7A-502 ENLARGED KITCHEN (ADA) PLAN, RCP, & ELEVATIONS 7A-511 ENLARGED BATHROOM PLAN, RCP, & ELEVATIONS 7A-512 ENLARGED BATHROOM (ADA) PLAN, RCP, & ELEVATIONS 7A-520 ENLARGED STAIR PLANS & SECTIONS 7A-900 PARTITION SCHEDULE AND TYPES 7A-910 DOOR & WINDOW SCHEDULE AND TYPES 7A-920 PLUMBING FIXTURE, PLUMBING ACCESSORIES, LIGHTING, FINISH SCHEDULES

0 Y2 W H

CODE SUMMARY APPLICABLE CODES

CD SET

DD SET

• • • • • • • • • • • • • • • • •

24025 HWY 120 Groveland, CA 95321

RE

GENERAL 7G-000 COVER SHEET 7G-001 PROJECT INFORMATION 7G-011 1ST FLOOR & BASEMENT CODE PLAN 7G-012 2ND FLOOR CODE PLAN 7G-020 MOUNTING HEIGHT REQUIREMENTS

STAFF HOUSING

FE R

SHEET NAME

1490 N LAFAYETTE STREET, SUITE 408 DENVER, CO 80218 610.442.1739

FIREFALL LODGE

STAFF HOUSING

TUOLUMNE RIVER

SHEET NUMBER

SD SET

FIREFALL LODGE

LOCATION PLAN

SHEET LIST

California Building Code 2019 (Vol 1 & 2) California Administrative Code 2019 California Electrical Code - 2019 California Mechanical Code - 2019 California Plumbing Code - 2019 California Energy Code - 2019 California Fire Code - 2019 California Building Code Reference Standards - 2019

STAMP & SIGNATURE:

International Property Maintenance - 2019 California Green Building Standards Code 2019 USE AND OCCUPANCY CLASSIFICATION

OCCUPANCY: R-2 (APARTMENTS) B (LAUNDRY/STORAGE) CONSTRUCTION TYPE

VB

6,342 SF

SPRINKLER TYPE

13R

CLIMATE ZONE

History

16 FIRE SEPARATION DISTANCE REQUIREMENTS

EXTERIOR WALLS 10' MIN. FROM LINE FOR FSD PROJECTIONS GREATER THAN 5' FROM LINE FOR FSD

Date SCHEMATIC DESIGN

TABLE 602 TABLE 705.2

THIS IMAGE IS FOR GRAPHICAL REPRESENTATION ONLY AND SHOULD NOT BE USED FOR CONSTRUCTION

PROJECT TEAM

CALIFORNIA 11A ACCESSIBILITY STANDARDS STAFF HOUSING WILL MEET THE REQUIREMENTS OF: SECTION 11A HOUSING ACCESSABILITY TOTAL STAFF HOUSING: 12 MULTISTORY DWELLINGS TO COMPLY WITH 2019 CBC 11A-1102A.3.1 MULTISTORY APARTMENT OR CONFOMINIUM DWELLINGS IN BUILDINGS WITH NO ELEVATOR

10.21.2022

OWNER

ARCHITECT

STRUCTURAL & CIVIL ENGINEER

MECHANICAL & PLUMBING

ELECTRICAL ENGINEER

Boyer Construction

UNUM:collaborative

Land & Structure

MEC Inc.

Front Range Electrical Engineering

19608 East Mono Way, Sonora, CA 95370

1490 N Lafayette Street, Suite 408 Denver, CO 80218 www.unum-collab.com

105 South Stewart Street, Sonora, California 95370

4640 Pecos Street, Unit F Denver, CO 80211

3333 S. Wadsworth Blvd, Suite D210 Lakewood, CO 80227

POC: Zachariah P. Garman e: zac@landstruc.com p: 209.768.9220 c: 209.532.5173 f: 209.532.5220

POC: Bradley Gettel e: bgettel@mecengr.com p: 720.480.7720

POC: Jacob Bennefield e: jacob@freengineer.com p: 303.985.0548 c: 303.242.1572 f: 720.638.8870

POC: Robert Boyer e: robert@boyerbuild.com p: 209.586.5010 f: 209.586.5099

POC: Jim Pfeiffer e: jim@unum-collab.com p: 610.442.1739

DEFERRED SUBMITTALS THE FOLLOWING ITEMS ARE TO BE TREATED AS DEFERRED SUBMITTALS

THE ORIGINAL OF THIS DRAWING IS 24" X 36". IF THIS COPY IS ANY OTHER SIZE, IT HAS EITHER BEEN REDUCED OR ENLARGED.

DATE: PROJECT #: DRAWN BY: DESIGNED BY: CHECKED BY:

10.21.2022 2022.42 JH/EK JP/AS JP/AS

COVER SHEET