Selecting the Right Equipment John Morris Scientific offers an extensive range of temperature control equipment to meet your individual requirements. Purpose

Type

Heating Only

Heating & Cooling

Cooling Only

Temp Range

Heating Immersion Circulators Open Heating Bath Circulators Heating Circulators Forte HT Highly Dynamic Temp Control Systems Water Baths Refrigerated/Heating Circulators Ultra Low Refrigerated Circulators Presto Highly Dynamic Temp Control Systems Recirculating Coolers Calibration Baths Cryo-Compact Circulators Recirculating Coolers Immersion Coolers Refrigerators for Chemicals

+20ᵒC to +300ᵒC +20ᵒC to +150ᵒC +20ᵒC to +300ᵒC +40ᵒC to +400ᵒC +20ᵒC to +99.9ᵒC -50ᵒC to +200ᵒC -95ᵒC to +200ᵒC -92ᵒC to +250ᵒC -25ᵒC to +80ᵒC -38ᵒC to +300ᵒC -40ᵒC to +200ᵒC -25ᵒC to +40ᵒC -90ᵒC to +30ᵒC -2ᵒC to +12ᵒC

The following pages list basic product specifications (eg temperature range, heating/cooling capacity, fill volume, flow rate, pump pressure, etc) separately for Heating Only, Heating & Cooling and Cooling Only equipment - providing an overview of the range offered.

However, to ensure you select the right equipment for your particular application process, specific additional information is required - for example: Maintain or Control Temperature: Do you want to keep the temperature stable/constant or do you want to adjust the temperature throughout the process? Rapid Heating/Cooling: How quickly do you want to heat or cool or both (eg heat 10ᵒC an hour or 1ᵒC per minute)? Monitoring: How do you want to monitor the results, do you want to know what’s happening throughout the process (and do you want to record data and how), do you want an alarm (for when a set temperature is reached or another purpose)? Type of Material: What is the type and mass of the material solution to be heated or cooled or both?

The answers to these and other questions will ensure you select the right equipment for your particular demands.

To ensure you select the right temperaure control equipment for your needs, simply contact John Morris Scientific for professional assistance. Images of Heating Only Equipment

Immersion Circulator (EH)

Open Heating Bath Circulator (ED-19A)

Free Call: 1800 251 799

Open Heating Bath Circulator (ED-33)

2

Heating Circulator (MA-26)

Water Bath (TW20)

www.johnmorris.com.au


Heating Only Equipment Type

Immersion Circulators

Open Heating Bath Circulators

Heating Circulators

Forte Highly Dynamic Control Systems

Water Baths

Model ED EH MB MA ME SE-Z ED-5A/B ED-7A/B ED-5M/B ED-13A ED-19A ED-13M ED-19M MB-13A MB-19A ED-13 ED-17 ED-19 ED-27 ED-33 MB-13 MB-19 ED-5A ED-5M MB-5A MB-7A MB-5M ED-5 EH-5 EH-13 EH-19 EH-27 EH-33 EH-39 MB-5 MA-4 MA-6 MA-12 MA-26 ME-4 ME-6 ME-12 ME-26 HE-4 SE-6 SE-12 SE-26 HL-4 SL-6 SL-12 SL-26 HT30-M1 HT60-M2 HT60-M3 HT30-M1-C.U HT60-M2-C.U HT60-M3-C.U TW2 TW8 TW12 TW20 SW22 SW23

Temp Range +20ᵒ to +100ᵒC +20ᵒ to +150ᵒC +20ᵒ to +100ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +300ᵒC +20ᵒ to +60ᵒC +20ᵒ to +60ᵒC +20ᵒ to +60ᵒC +20ᵒ to +100ᵒC +20ᵒ to +60ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +60ᵒC +20ᵒ to +60ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +60ᵒC +20ᵒ to +100ᵒC +20ᵒ to +60ᵒC +20ᵒ to +60ᵒC +20ᵒ to +100ᵒC +20ᵒ to +100ᵒC +20ᵒ to +150ᵒC +20ᵒ to +150ᵒC +20ᵒ to +150ᵒC +20ᵒ to +150ᵒC +20ᵒ to +150ᵒC +20ᵒ to +150ᵒC +20ᵒ to +100ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +200ᵒC +20ᵒ to +250ᵒC +20ᵒ to +300ᵒC +20ᵒ to +300ᵒC +20ᵒ to +300ᵒC +20ᵒ to +250ᵒC +20ᵒ to +300ᵒC +20ᵒ to +300ᵒC +20ᵒ to +300ᵒC +70ᵒ to +400ᵒC +70ᵒ to +400ᵒC +70ᵒ to +400ᵒC +40ᵒ to +400ᵒC +40ᵒ to +400ᵒC +40ᵒ to +400ᵒC +20ᵒ to +99.9ᵒC +20ᵒ to +99.9ᵒC +20ᵒ to +99.9ᵒC +20ᵒ to +99.9ᵒC +20ᵒ to +99.9ᵒC +20ᵒ to +99.9ᵒC

Free Call: 1800 251 799

Fill Heating Capacity (kW) Volume (L) 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 2 3 3 3 3 7 6 3 7 6 1 2 2 2 2 2

Flow Rate Pump Size (cm) (L/min) Pressure (bar) W-L-H

- - - - - - 5 7 5 13 19 13 19 13 19 13 17 19 27 33 13 19 5 5 5 7 5 4.5 4.5 13 19 27 33 39 4.5 4.5 6 12 26 4.5 6 12 26 4.5 6 12 26 4.5 6 12 26 2 2 2 2 2 2 1-2 3-8 5-14 8-26 8-20 8-20

15 15 10 11-16 11-16 22-26 15 15 15 15 15 15 15 10 10 15 15 15 15 15 10 10 15 15 10 10 10 15 15 15 15 15 15 15 10 11-16 11-16 11-16 11-16 11-16 11-16 11-16 11-16 22-26 22-26 22-26 22-26 22-26 22-26 22-26 22-26 14-18 14-18 14-18 14-18 14-18 14-18 - - - - - -

3

0.35 0.35 0.12 0.23-0.45 0.23-0.45 0.4-0.7 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.12 0.12 0.35 0.35 0.35 0.35 0.35 0.12 0.12 0.35 0.35 0.12 0.12 0.12 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.12 0.23-0.45 0.23-0.45 0.23-0.45 0.23-0.45 0.23-0.45 0.23-0.45 0.23-0.45 0.23-0.45 0.4-0.7 0.4-0.7 0.4-0.7 0.4-0.7 0.4-0.7 0.4-0.7 0.4-0.7 0.4-0.7 0.8-1.2 0.8-1.2 0.8-1.2 0.8-1.2 0.8-1.2 0.8-1.2 - - - - - -

13-15-33 13-15-33 13-15-33 13-15-33 13-15-33 32-17-40 14-40-35 14-50-35 14-40-35 41-33-36 55-33-36 41-33-37 55-33-37 41-33-36 55-33-36 39-33-37 39-33-42 57-33-37 57-37-42 91-33-38 39-33-37 57-33-37 14-40-35 14-40-35 14-40-35 14-50-35 14-40-35 17-33-36 17-33-36 39-33-37 57-33-37 57-37-42 91-33-38 54-34-52 17-33-36 21-42-38 21-43-42 30-43-45 36-61-45 21-42-38 21-43-42 30-43-45 36-61-45 21-42-40 21-43-44 30-43-47 36-61-47 21-42-40 21-43-44 30-43-47 36-61-47 25-25-18 25-25-18 25-25-18 25-25-18 25-25-18 25-25-18 17-16-37 29-32-44 40-32-44 56-35-49 70-35-43 70-35-43

Weight (kg) 3.3 3.3 3.3 4 4 8 5.3 5.6 5.2 7.5 8.5 7.5 8.5 7.5 8.5 8 10 11 13 20 8 11 5.3 5.2 5.3 5.6 5.2 7 7 8 11 13 20 19 7 9.6 12.5 13 26 9.6 12.5 13 26 11 13.5 14 27 11 13.5 14 27 27 29 29 35 37 37 3.5 8.5 9.8 14.2 19.4 21.4

Application Examples Very flexible for a variety of bath tanks plus suitable for a wide range of applications (eg temperature applications for samples, analytics, material testing)

Temperature applications for preparation of samples (serology & clinical chemistry), analytics, material testing, life sciences, agriculture & other diverse applications

Temperature applications for preparation of samples (serology & clinical chemistry), analytics, material testing, external temperature control (with measuring instruments), measuring cells, photometers, refractometers, polarimeters

External temperature application in combination with jacketed reactors, distillation apparatus, mini-plant applications, photometers, refractometers & temperature applications to small objects

Designed for high temperature control in closed external systems

Routine applications (eg cell cultivation), temperature control of samples, incubation, corrosion tests, test food & beverages Biochemical, enzyme & tissue studies, homogenisation, fermentation, incubation, blood plasma thawing, test food & beverages

www.johnmorris.com.au


John Morris

John Morris Scientific Service plus Solutions

Scientific

Heating & Cooling Equipment Type

Refrigerated /Heating Circulators

Ultra-Low Refrigerated Circulators

Model F12-ED F25-ED F26-ED F34-ED F12-EH F25-EH FN25-EH F32-EH FN32-EH F33-EH F34-EH F38-EH F12-MA F25-MA FN25-MA F32-MA FN32-MA F33-MA F34-MA FP35-MA FP40-MA FP50-MA FPW50-MA F25-ME FN25-ME F26-ME F32-ME FN32-ME F33-ME F34-ME FP40-ME FP50-ME FPW50-ME F25-HE FN25-HE F32-HE FN32-HE F34-HE FP40-HE FP45-HE FP50-HE FPW50-HE F25-HL FN25-HL F32-HL FN32-HL F33-HL FP35-HL FP40-HL FP45-HL FP50-HL FPW50-HL F70-ME F81-ME FP89-ME FP51-SL FP52-SL FP55-SL F81-HL FP89-HL FP90-SL FPW52-SL FPW55-SL FPW90-SL FPW91-SL F95-SL FW95-SL

Heating Cooling Fill Flow Rate Pump Temp Range Capacity at 20ᵒC Capacity Volume (L) (L/min) Pressure(bar) (kW) (kW) -20ᵒ to +100ᵒC 0.16 2 4.5 15 0.35 -28ᵒ to +100ᵒC 0.26 2 4.5 15 0.35 -28ᵒ to +100ᵒC 0.26 2 4.5 15 0.35 -30ᵒ to +100ᵒC 0.45 2 20 15 0.35 -20ᵒ to +150ᵒC 0.16 2 4.5 15 0.35 -28ᵒ to +150ᵒC 0.26 2 4.5 15 0.35 -28ᵒ to +150ᵒC 0.26 2 4.5 15 0.35 -35ᵒ to +150ᵒC 0.45 2 8 15 0.35 -35ᵒ to +150ᵒC 0.45 2 8 15 0.35 -30ᵒ to +150ᵒC 0.50 2 16 15 0.35 -30ᵒ to +150ᵒC 0.45 2 20 15 0.35 -35ᵒ to +80ᵒC 0.92 2 45 15 0.35 -20ᵒ to +200ᵒC 0.16 2 4.5 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 11-16 0.23-0.45 -35ᵒ to +200ᵒC 0.45 2 8 11-16 0.23-0.45 -35ᵒ to +200ᵒC 0.45 2 8 11-16 0.23-0.45 -30ᵒ to +200ᵒC 0.50 2 16 11-16 0.23-0.45 -30ᵒ to +150ᵒC 0.45 2 20 11-16 0.23-0.45 -35ᵒ to +150ᵒC 0.45 2 2.5 11-16 0.23-0.45 -40ᵒ to +200ᵒC 0.68 2 16 11-16 0.23-0.45 -50ᵒ to +200ᵒC 0.90 2 8 11-16 0.23-0.45 -50ᵒ to +200ᵒC 0.90 2 8 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 11-16 0.23-0.45 -35ᵒ to +200ᵒC 0.45 2 8 11-16 0.23-0.45 -35ᵒ to +200ᵒC 0.45 2 8 11-16 0.23-0.45 -30ᵒ to +200ᵒC 0.50 2 16 11-16 0.23-0.45 -30ᵒ to +150ᵒC 0.45 2 20 11-16 0.23-0.45 -40ᵒ to +200ᵒC 0.68 2 16 11-16 0.23-0.45 -50ᵒ to +200ᵒC 0.90 2 8 11-16 0.23-0.45 -50ᵒ to +200ᵒC 0.90 2 8 11-16 0.23-0.45 -28ᵒ to +200ᵒC 0.26 2 4.5 22-26 0.4-0.7 -28ᵒ to +200ᵒC 0.26 2 4.5 22-26 0.4-0.7 -35ᵒ to +200ᵒC 0.45 2 8 22-26 0.4-0.7 -35ᵒ to +200ᵒC 0.45 2 8 22-26 0.4-0.7 -30ᵒ to +150ᵒC 0.45 2 20 22-26 0.4-0.7 -40ᵒ to +200ᵒC 0.68 2 16 22-26 0.4-0.7 -42ᵒ to +200ᵒC 0.85 2 26 22-26 0.4-0.7 -50ᵒ to +200ᵒC 0.90 2 8 22-26 0.4-0.7 -50ᵒ to +200ᵒC 0.90 2 8 22-26 0.4-0.7 -28ᵒ to +200ᵒC 0.26 2 4.5 22-26 0.4-0.7 -28ᵒ to +200ᵒC 0.26 2 4.5 22-26 0.4-0.7 -35ᵒ to +200ᵒC 0.45 2 8 22-26 0.4-0.7 -35ᵒ to +200ᵒC 0.45 2 8 22-26 0.4-0.7 -30ᵒ to +200ᵒC 0.50 2 16 22-26 0.4-0.7 -35ᵒ to +150ᵒC 0.45 2 2.5 22-26 0.4-0.7 -40ᵒ to +200ᵒC 0.68 2 16 22-26 0.4-0.7 -42ᵒ to +200ᵒC 0.85 2 26 22-26 0.4-0.7 -50ᵒ to +200ᵒC 0.90 2 8 22-26 0.4-0.7 -50ᵒ to +200ᵒC 0.90 2 8 22-26 0.4-0.7 -70ᵒ to +100ᵒC 0.34 1.3 4.5 11-16 0.23-0.45 -81ᵒ to +100ᵒC 0.45 1.3 6.5 11-16 0.23-0.45 -90ᵒ to +100ᵒC 1.0 1.3 8 11-16 0.23-0.45 -51ᵒ to +200ᵒC 2.0 3 11 22-26 0.4-0.7 -60ᵒ to +100ᵒC 3.0 3 24 22-26 0.4-0.7 -60ᵒ to +100ᵒC 5.2 3 27 22-26 0.4-0.7 -81ᵒ to +100ᵒC 0.45 1.3 6.5 22-26 0.4-0.7 -90ᵒ to +100ᵒC 1.0 1.3 8 22-26 0.4-0.7 -90ᵒ to +100ᵒC 1.8 3 22 22-26 0.4-0.7 -60ᵒ to +100ᵒC 3.0 3 24 22-26 0.4-0.7 -60ᵒ to +100ᵒC 5.5 3 27 22-26 0.4-0.7 -90ᵒ to +100ᵒC 1.8 3 22 22-26 0.4-0.7 -91ᵒ to +100ᵒC 4.5 3 22 22-26 0.4-0.7 -95ᵒ to 0ᵒC - 3 22 22-26 0.4-0.7 -95ᵒ to 0ᵒC - 3 22 22-26 0.4-0.7

Free Call: 1800 251 799

4

Size (cm) Weight W-L-H (kg) 20-36-56 23-42-61 42-42-42 38-58-62 20-36-56 23-42-61 23-50-61 31-42-64 31-50-64 36-46-69 38-58-62 46-70-89 20-36-56 23-42-61 23-50-61 31-42-64 31-50-64 36-46-69 38-58-62 31-42-64 37-46-69 42-49-70 42-49-70 23-42-61 23-50-61 42-42-42 31-42-64 31-50-64 36-46-69 38-58-62 37-46-69 42-49-70 42-49-70 23-42-64 23-50-64 31-42-66 31-50-66 38-58-64 37-46-71 38-58-69 42-49-72 42-49-72 23-42-64 23-50-64 31-42-66 31-50-66 36-46-71 31-42-66 37-46-71 38-58-59 42-49-72 42-49-72 42-54-71 50-58-88 55-60-90 46-55-89 59-76-116 85-76-116 50-58-89 55-60-92 59-76-116 59-76-116 59-76-116 59-76-116 85-76-116 59-76-116 59-76-116

22 30 30 41 22 30 31 36 37 43 41 67 23 31 32 37 38 44 42 37 48 55 55 31 32 31 37 38 44 42 48 55 55 32 33 38 39 44 49 53 57 57 32 33 38 39 45 38 49 53 57 57 63 86 133 90 156 182 88 135 195 153 163 188 296 201 198

Application Examples

Routine applications (eg immersing samples for temperature studies in the circulator baths) plus external temperature control applications (eg measuring cells, refractometers, polarimeters, photometers, viscometers, fermenters, electrophoresis chambers, chromatography columns, rotary evaporators, Rheometers)

Designed for more demanding applications & feature increased functionality plus additional warning & safety functions

For a wide range of applications - units have a connection for external Pt100 sensor for direct measuring & control (VFD Comfort display features easy operation & shows all temperature values on one display)

External temperature control applications, particularly for distillation apparatus & mini-plant installations, jacketed reactors, autoclaves, Kilo labs, pilot plants

Freezing point determination, calibration at low temperatures, Petroleum testing, ultra-low temperature cell culture storage

Jacketed reactors, mini-plants, Kilo labs, process development

www.johnmorris.com.au


Heating & Cooling Equipment Cooling Heating Fill Flow Rate Pump Temp Range Capacity at 20ᵒC Capacity Volume (L) (L/min) Pressure(bar) (kW) (kW) A30 -30ᵒ to +250ᵒC 0.5 2.7 - 25 0.5 A40 -40ᵒ to +250ᵒC 1.2 2.7 - 16-40 0.3-1.7 W40 -40ᵒ to +250ᵒC 1.2 2.7 - 16-40 0.3-1.7 A80 -80ᵒ to +250ᵒC 1.2 1.8 - 16-40 0.3-1.7 A80t -80ᵒ to +250ᵒC 1.2 3.4 - 16-40 0.3-1.7 W80 -80ᵒ to +250ᵒC 1.2 1.8 - 16-40 0.3-1.7 W80t -80ᵒ to +250ᵒC 1.2 3.4 - 16-40 0.3-1.7 W91 -91ᵒ to +250ᵒC 11.0 12 - 26-80 0.5-3.0 Presto W91t -91ᵒ to +250ᵒC 11.0 24 - 26-80 0.5-3.0 Highly W91tt -91ᵒ to +250ᵒC 11.0 36 - 26-80 0.5-3.0 Dynamic W91x -91ᵒ to +250ᵒC 11.0 12 - 18-70 0.8-5.5 Temp W91tx -91ᵒ to +250ᵒC 11.0 24 - 18-70 0.8-5.5 Control W91ttx -91ᵒ to +250ᵒC 11.0 36 - 18-70 0.8-5.5 Systems W92 -92ᵒ to +250ᵒC 31.0 12 - 26-80 0.5-3.0 W92t -92ᵒ to +250ᵒC 31.0 24 - 26-80 0.5-3.0 W92tt -92ᵒ to +250ᵒC 31.0 36 - 26-80 0.5-3.0 W92x -92ᵒ to +250ᵒC 31.0 12 - 18-70 0.8-5.5 W92tx -92ᵒ to +250ᵒC 31.0 24 - 18-70 0.8-5.5 W92ttx -92ᵒ to +250ᵒC 31.0 36 - 18-70 0.8-5.5 LH46 -45ᵒ to +250ᵒC 2.5 1.8 - 16-30 0.5-1.6 LH47 -47ᵒ to +250ᵒC 3.7 1.8 - 16-30 0.5-1.6 LH50 -50ᵒ to +250ᵒC 5.5 6.0 - 16-30 0.7-2.2 Magnum 91 -91ᵒ to +250ᵒC 3.0 6.0 - 30-50 0.8-1.9 FC600 -20ᵒ to +80ᵒC 0.6 1.2 6-8 20 0.5 FC600S -10ᵒ to +80ᵒC 0.5 1.2 6-8 22 1.2 FC1200 -20ᵒ to +80ᵒC 1.3 1.2 8-11 20 0.5 FC1200S -15ᵒ to +80ᵒC 1.2 1.2 8-11 22 1.2 FC1600 -20ᵒ to +80ᵒC 1.65 1.2 8-11 20 0.5 Recirculating FC1600S -15ᵒ to +80ᵒC 1.55 1.2 8-11 22 1.2 Coolers FC1299T -10ᵒ to +80ᵒC 1.1 1.2 8-11 28 3.5 FC1600T -15ᵒ to +80ᵒC 1.45 1.2 8-11 28 3.5 FCW600 -20ᵒ to +80ᵒC 0.6 1.2 6-8 20 0.5 FCW600S -10ᵒ to +80ᵒC 0.5 1.2 6-8 22 1.2 FCW2500T -25ᵒ to +80ᵒC 2.5 1.2 8-11 28 3.5 SC2500a +5ᵒ to +35ᵒC 2.5 - 21-33 33 3.5 SC2500w +5ᵒ to +35ᵒC 2.5 - 21-33 33 3.5 SC5000a +5ᵒ to +35ᵒC 5.0 - 43-60 33 3.5 SC5000w +5ᵒ to +35ᵒC 5.0 - 43-60 33 3.5 SC10000w +5ᵒ to +35ᵒC 10.0 - 43-60 33 3.5 SL-8K +50ᵒ to +300ᵒC - 3 8 22-66 0.4-0.7 SL-14K +50ᵒ to +300ᵒC - 3 14 22-66 0.4-0.7 FK30-SL -30ᵒ to +200ᵒC 0.46 2 14 22-66 0.4-0.7 Calibration FK31-SL -30ᵒ to +200ᵒC 0.46 2 24 22-66 0.4-0.7 Baths ME-31A +20ᵒ to +60ᵒC - 2 31 11-16 0.23-0.45 ME-16G +20ᵒ to +100ᵒC - 2 16 11-16 0.23-0.45 ME-18V +20ᵒ to +150ᵒC - 2 18 11-16 0.23-0.45 Type

Model

F38-ME CF30 CryoCF40 Compact CF31 Circulators CF41

Size (cm) Weight W-L-H (kg) 25-59-62 33-59-67 33-59-67 43-65-126 43-65-126 43-65-126 43-65-126 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 95-127-190 50-59-64 40-55-127 40-55-127 71-88-165 35-54-49 35-54-49 46-61-49 46-61-49 46-61-49 46-61-49 46-61-49 46-61-49 35-54-49 35-54-49 46-61-49 49-62-105 49-62-105 59-67-112 59-67-112 59-67-112 22-46-47 22-46-61 32-45-79 32-45-91 50-20-56 Ø 29-48 36-24-54

Application Examples

62 79 78 164 167 159 162 770 780 790 785 795 805 785 795 805 800 810 820 103 150 182 442 48 52 60 66 65 66 67 67 48 52 74 123 123 153 153 159 16 20 48 51 11 9 17

Calibration for determination of conformity to national and international standards such as temperature sensors, measuring devices or thermometers Measurements with capillary viscometers or use of densimeters & other related products (enabling conformity to ASTM D445)

Jacketed reactors, reactor systems & autoclaves (polymerisation, poly-condensation, etc), combinatorial chemistry, reaction blocks, organic synthesis, reaction calorimeters, distillation, pilot plants, semiconductor industry

Reactor systems, mini plants, pilot plants, Kilo labs, process technology, vacuum chambers

Rotary evaporators, electron microscopes, lasers, mills & kneaders, pilot plants, plastics industry, drying of gases, general industrial applications

Semi-conductor industry, packaging & plastics industries, metering & adhesive technology, jacketed reaction vessels, Kilo labs, pilot plants

-38ᵒ to +80ᵒC

0.92

2

45

11-16

0.23-0.45 46-70-89

72

Forcing tests, ‘best before’ date by simulating beer aging process

-30ᵒ to +150ᵒC -40ᵒ to +150ᵒC -30ᵒ to +200ᵒC -40ᵒ to +200ᵒC

0.32 0.47 0.32 0.47

2 2 2 2

3.5 5.5 3.5 5.5

15 15 22-26 22-26

0.35 0.35 0.4-0.7 0.4-0.7

35 41 36 42

External temperature control applications, distillation apparatus & mini-plant installations, limited space (in fume hoods)

24-46-40 28-46-46 24-46-40 28-46-46

Images of Heating & Cooling Equipment

Refrigerated/Heated Circulator (F12-ED)

Refrigerated/Heated Circulator (F25-MA)

Free Call: 1800 251 799

Ultra-Low Circulator (FP52-SL)

5

Presto Highly Dynamic (A40)

Recirculating Cooler (SC2500a)

www.johnmorris.com.au


John Morris

John Morris Scientific Service plus Solutions

Scientific

Cooling Only Equipment Type

Model

F250 F500 F1000 AWC100 FL300 FL601 FL1201 FL1203 Recirculating FL1701 Coolers FL1703 FLW1701 FLW1703 FL2503 FL2506 FL4003 FL4006 FLW2503 FLW2506 FLW4003 FLW4006 FL7006 FL11006 FL20006 FLW7006 FLW11006 FLW20006 FT200 FT400 Immersion FT900 FT402 Coolers FT902 FD200 KRC50 For Chemicals KRC180

Temp Range

Cooling capacity at 20ᵒC (kW)

Fill Volume (L)

Flow Rate Pump Size (cm) Weight (L/min) Pressure (bar) W-L-H (kg)

Application Examples

-10ᵒ to +40ᵒC 0ᵒ to +40ᵒC 0ᵒ to +40ᵒC +20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -15ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -15ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -25ᵒ to +40ᵒC -20ᵒ to +40ᵒC -20ᵒ to +40ᵒC -25ᵒ to +40ᵒC -20ᵒ to +30ᵒC -40ᵒ to +30ᵒC -90ᵒ to +30ᵒC -40ᵒ to +30ᵒC -90ᵒ to +30ᵒC

0.25 0.5 1.0 0.55 0.3 0.6 1.2 1.2 1.7 1.7 1.7 1.7 2.5 2.5 4.0 4.0 2.7 2.5 4.3 4.0 7.0 11.0 20.0 7.4 11.5 20.0 0.25 0.45 0.3 0.45 0.3

1.7-2.6 5-7.5 7-9.5 0.9 3-4.5 5.5-8 12-17 12-17 12-17 12-17 12-17 12-17 24-30 24-30 24-30 24-30 24-30 24-30 24-30 24-30 39-47 39-47 15-37 39-47 39-47 15-37 - - - - -

15 24 23 2.9 15 23 23 40 23 40 23 40 40 60 40 60 40 60 40 60 60 60 80 60 60 80 - - - - -

0.35 0.5 1.0 0.2 0.35 1.0 1.0 0.5-3.0 1.0 0.5-3.0 1.0 0.5-3.0 0.5-3.0 0.5-6.0 0.5-3.0 0.5-6.0 0.5-3.0 0.5-6.0 0.5-3.0 0.5-6.0 0.5-6.0 0.5-6.0 0.8-6.0 0.5-6.0 0.5-6.0 0.8-6.0 - - - - -

24-40-52 37.5-44-59 37.5-49-64 20-34-30 25-50-60 32-50-60 50-76-64 50-76-64 50-76-64 50-76-64 50-76-64 50-76-64 60-76-115 60-76-115 60-76-115 60-76-115 60-76-115 60-76-115 60-76-115 60-76-115 78-85-148 78-85-148 95-115-161 78-85-148 78-85-148 95-115-161 18-27-39 20-30-43 38-55-60 20-30-43 38-55-60

27 34 45 11 39 48 76 91 85 91 82 88 146 158 148 157 143 160 143 160 252 248 360 220 250 360 18 24 50 24 50

Cooling of Peltier elements, particularly for automated analysis units & CCD cameras, polarimeters, refractometers, electrophoresis chambers, condensers for glass apparatus

+10ᵒ to +30ᵒC

0.22

-

-

-

18-27-39

16

Heating circulators for sub-ambient temp, integration into loop circuits

-2ᵒ to +12ᵒC -2ᵒ to +12ᵒC

- -

50 180

- -

- -

53-63-54 60-64-86

23 35

Storing & cooling of chemicals & hazardous substances

Rotary evaporators, bio-reactors/ fermenters, Soxhlet apparatus, distillation systems, vacuum systems, gas chromatographs, spectrometers, semiconductor applications, metering & adhesive technology, diffusion pumps, mass spectrometers, electron microscopes

Electron microscopes, lasers, mills & kneaders, pilot plants, plastics industry, drying of gases, general industrial applications

Cooling of liquids, dry-ice substitute, counter-cooling for heating circulators, saving of tap water

German quality with a full 2 year warranty

Images of Cooling Only Equipment

Recirculating Cooler (F250)

Recirculating Cooler (FL300)

Free Call: 1800 251 799

Recirculating Cooler (FL601)

6

Recirculating Cooler (FL1203)

Recirculating Cooler (FL1703)

www.johnmorris.com.au


Evaporation & Concentration Commonly used in laboratories for synthetic chemistry, organic chemistry, scale-ups or in R&D labs for pharmaceuticals, chemicals, cosmetics and nutritional chemistry. Evaporation and concentration without consumption of water, elevated efficiency even at cooling temperatures as low as -10°C. John Morris Scientific also supplies an extensive range of Vacuubrand vacuum pumps.

Wireless Operation WirelessTEMP products allow wireless monitoring and operation of up to eight Julabo temperature control instruments via PC or remote control: • • • • •

Comfortable operation of instruments directly from your workstation Reduces time and resources for monitoring the instruments Increased freedom in choosing a location for the instrument No need for communication cables Easy to handle remote control

Remote control to control & monitor up to 8 Julabo instruments

PC & Wireless USB Stick to control & monitor up to 8 Julabo instruments

Accessories John Morris Scientific also has an extensive range of Julabo accessories & spare parts.

Repairs & Maintenance Our Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Julabo temperature control equipment to ensure it is operating to its optimum capacity.

To ensure you select the right temperaure control equipment for your needs or for servicing your equipment, simply contact John Morris Scientific for professional assistance.

Free Call: 1800 251 799

7

www.johnmorris.com.au


At John Morris Scientific we offer more than just the product - we provide the full package sales and servicing of instrumentation plus design tailored solutions to meet your needs.

John Morris Scientific

John Morris Scientific Service plus Solutions Head Office Address Free Call Enquiries Email Web

61-63 Victoria Avenue Chatswood NSW 2067 Australia 1800 251 799 +61 (0) 2 9496 4200 info@johnmorris.com.au www.johnmorris.com.au

PROUDLY AUSTRALIAN

For Over 50 Years


Julabo temp control summary aust