Hardware Setup Settings SINGLE SERVICE 230V 1þ / 1x32A & 1x16A, THREE-SERVICE 230V 3þ / 3x16A LOCATION J9 J14

J15 J21 J32 J33 J44

DEVICE NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPD PUMP 1 1-SPD PUMP 2 / BLOWER NETZSTROMVERSORGUNG 1-GESCHW.-PUMPE 2 / SPRUDELGEBLASE ALIMENTATION POMPE 2 A 1 VITESSE / VENTILATEUR 10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP OZONGENERATOR GENERATOROZONE OZONE GENERATOR TV / AV HEATER

MAX AMPS 6.5A - 12A MAX

SWITCHBANK S1 OFF 230V 1þ 1x32A

TEST MODE OFF DON’T ADD 1 HS PUMP W/HTR DON’T ADD 2 HS PUMPS W/HTR DON’T ADD 4 HS PUMPS W/HTR SPECIAL AMPERAGE RULE A STORE SETTINGS* 1 MIN HTR COOLDOWN (ELEC) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED

6.5A - 12A MAX / 4A MAX 2A* (@10V) 2A 0.5A 2A 3.0kW

* 2A LIMIT IS SHARED BY J15 SPA LIGHT AND CHROMAZONE™

SWITCHBANK S1 ON A1 A2 A3 A4 A5 A6 A7 A8 A9 A10

*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

SWITCHBANK S1 OFF

2

GRN

3

3

REMOVE JUMPER WIRES J51-J58 J52-J36

FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF 60°C AMPACITY BUT RATED MINIMUM OF 90°C.

3 BRN

4

1 BRN

1

BLU 2 BRN

2

GRN

J45 J54 J77 J78 J79

J41 J60 TB1

3

J53 J12 J58 J36

BLU BRN

A5

TEST MODE OFF DON’T ADD 1 HS PUMP W/HTR DON’T ADD 2 HS PUMPS W/HTR DON’T ADD 4 HS PUMPS W/HTR SPECIAL AMPERAGE RULE A STORE SETTINGS* 1 MIN HTR COOLDOWN (ELEC) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED

3

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10

TEST MODE ON ADD 1 HS PUMP WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD 4 HS PUMPS WITH HEAT SPECIAL AMPERAGE RULE B MEMORY RESET* 5 MIN HTR COOLDOWN (GAS) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED

*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.

REMOVE JUMPER WIRES J51-J58 J52-J36

USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE.

TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)

BP6013G1 – PN 56610-06 12-13-18

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.

Template 56377 10-05-12

SWITCHBANK S1 ON

J62 J88

BRN

1

4

A3 J53 J12 J58 J36

4

ON A2

J62 J88

BLU

TB1

230V 1þ 1x16A

230V 3þ 3x16A OFF

4

A3 A5

J18

J45 J54 J77 J78 J79

A2

J20

J41 J60

ON

OFF

J46

230V 2þ 2x16A

TEST MODE ON ADD 1 HS PUMP WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD 4 HS PUMPS WITH HEAT SPECIAL AMPERAGE RULE B MEMORY RESET* 5 MIN HTR COOLDOWN (GAS) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED