Hardware Setup Settings SINGLE SERVICE 230V 1þ / 1x32A & 1x16A, THREE-SERVICE 230V 3þ / 3x16A LOCATION J9 J14
J15 J21 J32 J33 J44
DEVICE NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPD PUMP 1 1-SPD PUMP 2 / BLOWER NETZSTROMVERSORGUNG 1-GESCHW.-PUMPE 2 / SPRUDELGEBLASE ALIMENTATION POMPE 2 A 1 VITESSE / VENTILATEUR 10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP OZONGENERATOR GENERATOROZONE OZONE GENERATOR TV / AV HEATER
MAX AMPS 6.5A - 12A MAX
SWITCHBANK S1 OFF 230V 1þ 1x32A
TEST MODE OFF DON’T ADD 1 HS PUMP W/HTR DON’T ADD 2 HS PUMPS W/HTR DON’T ADD 4 HS PUMPS W/HTR SPECIAL AMPERAGE RULE A STORE SETTINGS* 1 MIN HTR COOLDOWN (ELEC) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED
6.5A - 12A MAX / 4A MAX 2A* (@10V) 2A 0.5A 2A 3.0kW
* 2A LIMIT IS SHARED BY J15 SPA LIGHT AND CHROMAZONE™
SWITCHBANK S1 ON A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
SWITCHBANK S1 OFF
2
GRN
3
3
REMOVE JUMPER WIRES J51-J58 J52-J36
FOR SUPPLY CONNECTIONS, USE CONDUCTORS SIZED ON THE BASIS OF 60°C AMPACITY BUT RATED MINIMUM OF 90°C.
3 BRN
4
1 BRN
1
BLU 2 BRN
2
GRN
J45 J54 J77 J78 J79
J41 J60 TB1
3
J53 J12 J58 J36
BLU BRN
A5
TEST MODE OFF DON’T ADD 1 HS PUMP W/HTR DON’T ADD 2 HS PUMPS W/HTR DON’T ADD 4 HS PUMPS W/HTR SPECIAL AMPERAGE RULE A STORE SETTINGS* 1 MIN HTR COOLDOWN (ELEC) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED
3
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
TEST MODE ON ADD 1 HS PUMP WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD 4 HS PUMPS WITH HEAT SPECIAL AMPERAGE RULE B MEMORY RESET* 5 MIN HTR COOLDOWN (GAS) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
REMOVE JUMPER WIRES J51-J58 J52-J36
USE COPPER CONDUCTORS ONLY. EMPLOYER UNIQUEMENT DES CONDUCTEURS DE CUIVRE.
TORQUE RANGE FOR MAIN TERMINAL BLOCK (TB1): 27-30 IN. LBS. (31.1-34.5 kg cm)
BP6013G1 – PN 56610-06 12-13-18
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
SWITCHBANK S1 ON
J62 J88
BRN
1
4
A3 J53 J12 J58 J36
4
ON A2
J62 J88
BLU
TB1
230V 1þ 1x16A
230V 3þ 3x16A OFF
4
A3 A5
J18
J45 J54 J77 J78 J79
A2
J20
J41 J60
ON
OFF
J46
230V 2þ 2x16A
TEST MODE ON ADD 1 HS PUMP WITH HEAT ADD 2 HS PUMPS WITH HEAT ADD 4 HS PUMPS WITH HEAT SPECIAL AMPERAGE RULE B MEMORY RESET* 5 MIN HTR COOLDOWN (GAS) NOT ASSIGNED NOT ASSIGNED NOT ASSIGNED
6
56610-06_56611-06_56612-06_56731-06_56941-01_56986-01_97_A
12-13-18
PART B