Wacker Neuson WL28 Wheel loader Operating Manual - PDF DOWNLOAD

Page 30

Basic safety instructions

2.4.2

Working in the vicinity of overhead power lines

DANGER Risk of fatal electrical shock due to contact with overhead power lines! ►► Keep the loader and attachments at a safe distance to overhead power lines and other electrical lines with a voltage of more than 50 V. ►► Read the information about the relevant safety distances which need to be maintained.

Rated voltage

Safety distance

Up to 1000 V

1m

3.3 ft.

Above 1 kV and up to 110 kV

3m

9.8 ft.

Above 110 kV and up to 220 kV

4m

13.1 ft.

Above 220 kV and up to 380 kV

5m

16.4 ft.

Unknown rated voltage

5m

16.4 ft.

28

If it is not possible to maintain a sufficient distance to overhead power lines, the owner/operator must put alternative safety measures in place in conjunction with the owner or operator of the power lines, for example by arranging to have the electrical power switched off. What to do after contact with cables carrying high voltage current: --Do not get out of the loader. --Drive the loader away from the danger area. --Warn any people around the loader not to come any closer or touch the vehicle. --Arrange to have the power switched off. --Do not get out of the loader until you are sure that the cable you came into contact with and which is now damaged has been disconnected from the electrical supply and is definitely no longer carrying a live voltage.