Group 30: Electrical system

Malfunctions, MID 128

MID 128, PID 100 Oil pressure sensor (engine)

MID 128: Engine control unit Fault code FMI 0: The sensor value is valid but exceeds the normal working range. FMI 1: The sensor value is valid but is less than the normal working range. FMI 3: The voltage exceeds the normal value or is short circuited to higher voltage. FMI 4: The voltage is less than the normal value or is short circuited to battery negative. FMI 5: The current is less than the normal value or is open circuited. FMI 6: The current is greater than the normal value or is short circuited to battery negative. FMI 9: Abnormal updating rate. FMI

Fault code explanation

0

Too high lube oil pressure

1

Too low lube oil pressure

3, 4, 5, 6, 9

Faulty sensor / Faulty sensor circuit

Fault indication Warning is displayed in the tachometer/display. FMI 1:

Oil pressure indication in alarm display shows red. Audible warning.

FMI 0, 3, 4, 5, 6, 9: A red lamp flashes in the alarm display.

Symptom Engine power is limited.