2 minute read
Cables and cable harnesses, all engines
from Volvo Penta D4, D6, D9, D12, D16 Electronic Vessel Control Installation Manual_51339553 PDF DOWNLOAD
Standard bus cable, 6-pin
Y-split multilink, 6-pin
The cable must be used to connect the PCU to the HCU.
NOTE! The cable has female connections in both ends and cannot be used as an extension. Two female connectors.
Length m: 5, 7, 9, 11, 13
Length ft: 16, 23, 30, 36, 42
Y-connector, EVC bus cable, 6-pin
For making branches in the multilink cabling, EVC display–sync. connection–NMEA-connection.
NOTE! Do not install an Y-split cable without having the MULTILINK BREAKOUT connected.
Length, m (ft): 0.5 (1.6)
Y-connector to 4–20 mA output interface, engine transmission cable, 8 and 12-pin
To connect the standard bus cable to the HCU in systems with secondary helm stations.
Length, m: 0.25 x 0.25 x 0.5
Length, ft: 0.8 x 0.8 x 1.6
To connect the 4–20 mA interface output to an aftermarket control system supporting 4–20 mA, i.e. a CP-control (pitch) system.
The cable is connected to the EMS unit cable (ENGINE CONN) on the engine/transmission cable harness.
This connector is not used on D4 and D6 engines with sterndrive DPH and DPR.
Length, m: 0.2 x 2.0
Length, ft: 0.7 x 6
Display cable, 6-pin/12-pin
Key switch and relay cable, 6-pin
To connect the EVC System Display to the multilink cable or the MULTILINK BREAKOUT on the Y-split cable from connection X5 on the HCU.
Two female connectors
Length, m (ft): 1.5 (5)
Control lever cable, 6-pin
Connects the key switch to the HCU. The relay to external accessories, if used, should be connected to the relay socket included in the cable.
Length, m (ft), connector–key: 1.5 (5)
Length, m (ft), connector–relay: 1.5 (5)
Start/stop panel and relay cable, 6-pin (option)
Connects the control or the adapter for mechanical controls to the HCU.
Length, m (ft): 1.5 (5)
This cable is used in combination with the Start/stop panel and connects the panel and the relay socket to the HCU. The relay to external accessories shall be mounted on the relay socket.
Length,
(ft): 1.5 (5)
Multilink/tachometer and sychronization cable, 6-pin
Extension cables, all engines
6-pin
This cable has female/female connectors. It is used to connect the tachometer to the multilink chain. In a twin installation the cable is used to connect both the HCUs, to synchronize the engines.
Two female connectors
Length, m (ft): 1.5 (5)
Instrument, panels and auxiliary cable, 6-pin (option)
This cable is used as a synchronisation cable extension.
It is also used as an extension in all other 6-pin, male/female combinations.
Male and female connectors.
Length m: 1.5, 3, 5, 7, 9, 11
Length ft: 5, 10, 16, 23, 30, 36
Instruments, 3-pin
Connection of instrument to instrument when distance exceeds 220 mm (8.6").
Length m (ft): 1, 3 (3, 10)
GAUGES
This cable harness is used when an EVC system display substitutes a tachometer and/or when you need an additional buzzer. The harness connects the HCU to the instrument bus cable (easy link), the auxiliary bus and the buzzer
Length, m (ft): 1.5 (5)