3 Use

Starting

Ambient Temperature

Pre-heating time

Above + 5°C (41°F) about 6 seconds

VD00107

about 12 seconds

Below -5°C (23°F)

about 18 seconds

Maximum pre-heating time

1 minute

VD00108

10 Pre-heating Turn the start key on the instrument panel clock-wise; the warning lights for oil pressure and alternator will now light up and the alarm buzzer will sound.

+5°C to -5°C (+41°F to +23°F)

Turn the key further clockwise to the ­‘ position; only the pre-heating indicator light will be lit now.

11 Pre-heating time ’

Hold the key in this position for about 6 seconds.

The ideal pre-heating time depends on ambient temperature; the lower the ambient temperature, the longer the pre-heating time required. See table.   Caution To prevent the glow plugs from burning out, never exceed the stated maximum pre-heating time.