Vetus M-LINE Marine Diesel Engines Operation manual - pdf download

Page 70

6 Maintenance

Changing the gearbox oil Every 500 operating hours.

32  Draining the oil Drain the oil with the aid of a separate sump pump.

33  Filling with new oil Or, if sufficient space below the gearbox is available, oil can be drained by removing the drain plug.

• Remove the dipstick. • Insert the suction hose of the sump pump in the dipstick hole. Push down the pump handle quickly and pull it up slowly. • Remove the sump pump when all the old oil has been pumped out. 68

VD00975

14 / 17

VD02003

VD02004

OIL

• Refill the gearbox to the correct level via the dipstick opening. For oil specification see page 128.

• Remove the fillercap to vent the gearbox and check if all oil has been drained • Collect the oil in a dripping pan.

In case your engine is equipped with another brand of gearbox follow the instructions given in the supplied owners manual for changing oil and other care and maintenance.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Vetus M-LINE Marine Diesel Engines Operation manual - pdf download by www.heydownloads.com - Issuu