1 minute read

PQA Diagnostic Program Error Code and Messages

Next Article
TouchPad Check

TouchPad Check

The right corner screen information gives you the available function keys and the specified test number.

• Space Enables/disables the item • ESC Exits the program • F1 Help • F2 Tests the selected item(s) • Enter Opens the available suboptions • Test TimesIndicates the number of tests to perform.

Note: The F1 and F2 keys function only after you finish configuring the Test option.

Error Code Message Spare Part/Action in Sequence System

16XX Backup battery error Backup battery 1XXX CPU or Main board error 1. Reload BIOS default setting. 2. CPU 3. Main board

2XXX Memory error 1. Reconnector CPU(IMM module) 2. DIMM 3. Main board

3XXX Keyboard error 1. Reconnector Keyboard 2. Keyboard 3. Main board

4XXX Video error 1. Main board

5XXX Parallel Port error 1. Main board

6XXX Serial port or Main board error 1. Main board

7XXX Diskette drive error 1. Diskette drive 2. Main board

8XXX Hard disk error 1. Reload BIOS default setting. 2. Hard disk 3. Main board

9XXX CD-ROM error 1. Reconnector CD-ROM cable 2. CD-ROM drive 3. Main board

10XXX CPU or Main board error 1. CPU 2. Main board

11XXX Pointing device error 1. Reconnector Keyboard 2. Keyboard 3. Main board

74 TravelMate 310 Service Guide