1 minute read
PQA Diagnostic Program Error Code and Messages
The right corner screen information gives you the available function keys and the specified test number.
• Space Enables/disables the item • ESC Exits the program • F1 Help • F2 Tests the selected item(s) • Enter Opens the available suboptions • Test TimesIndicates the number of tests to perform.
Note: The F1 and F2 keys function only after you finish configuring the Test option.
Error Code Message Spare Part/Action in Sequence System
16XX Backup battery error Backup battery 1XXX CPU or Main board error 1. Reload BIOS default setting. 2. CPU 3. Main board
2XXX Memory error 1. Reconnector CPU(IMM module) 2. DIMM 3. Main board
3XXX Keyboard error 1. Reconnector Keyboard 2. Keyboard 3. Main board
4XXX Video error 1. Main board
5XXX Parallel Port error 1. Main board
6XXX Serial port or Main board error 1. Main board
7XXX Diskette drive error 1. Diskette drive 2. Main board
8XXX Hard disk error 1. Reload BIOS default setting. 2. Hard disk 3. Main board
9XXX CD-ROM error 1. Reconnector CD-ROM cable 2. CD-ROM drive 3. Main board
10XXX CPU or Main board error 1. CPU 2. Main board
11XXX Pointing device error 1. Reconnector Keyboard 2. Keyboard 3. Main board
74 TravelMate 310 Service Guide