1 minute read
Input/Output Signals of the AML-LIID System (GT-350C-1)
Names and functions of signals input to/output from CN3 connector are shown below:
CN 3 connector
Pin No. Name
2 TR2
3 TR3
4 TR4
22 Di22
Signal names and functions
Signal name: 90% alarm output
When the moment load factor is 90% or more and less than 100%, the OC (open collector) output turns ON.
OC output ON (DC 0 V): The external indicator lamp indicating 90% lights.
OC output OFF (DC 24 V): The external indicator lamp indicating 90% goes out.
While the boom lift is performed with the jib mounted, the OC output turns ON when the moment load factor is 75% or more and less than 85%.
Signal name: 100% alarm output
When the moment load factor is 100% or more, or when the overload and overwound automatic stop function is canceled, the OC (open collector) output turns ON.
OC output ON (DC 0 V): The external indicator lamp indicating 100% lights.
OC output OFF (DC 24 V): The external indicator lamp indicating 100% goes out.
Signal name: 100% alarm output
When the moment load factor is 100% or more, or when the overload and overwound automatic stop function is canceled, the OC (open collector) output turns ON.
OC output ON (DC 0 V): The external indicator lamp indicating 100% lights.
OC output OFF (DC 24 V): The external indicator lamp indicating 100% goes out.
Conditions under which the OC output turns ON
Moment load factor ≥ 100%
Overwind cutout release switch: "Press"
AML emergency switch: "非常用"
While the boom lift is performed with the jib mounted (extended), the OC output turns ON when the moment load factor becomes as follows:
Moment load factor ≥ 85%
Also, under the condition below, the AML judges that the jib is mounted (extended).
When Di8 input signal is "DC 24 V"
With GT-350C-1
Signal name: Front jack overload warning output
OC (open collector) output ON (DC 0 V): When the front jack overload detection switch is "ON," the buzzer sounds. OC (open collector) output OFF (DC 24 V): When the front jack overload detection switch is "OFF," the buzzer does not sound.
Signal name: Front jack/outrigger retracting operation input
Input from the outrigger retraction switch.
Switch ON (DC 0 V): Outrigger retracting operation
Switch OFF (DC 5 V): Not outrigger retracting operation
Signal name: Front jack overload detection switch input
23 Di23
Switch ON (DC 0 V): Not front jack overload state
Switch OFF (DC 5 V): Front jack overload state