New Holland E35B SR E39B SR Mini Excavators Service Manual 84553640A - PDF DOWNLOAD

Page 32

2. SPECIFICATIONS

2.9

LUBRICANT, FUEL AND COOLANT SPECIFICATIONS

The following table indicates the proper oils, lubricants and fuel to be used with various climates and service conditions. Components

Technical name

Operating range (ambient temperature °C)

Quantity

-20° -10° 0° 10° 20° 30° 40°

Hydraulic oil tank

Selenia IDRAULICAR AP31 Selenia IDRAULICAR AP46 Tank: 38 l Selenia IDRAULICAR AP51 System: 54.5 l Ambra HI-TECH 46

Engine oil pan

Ambra Supergold

Fuel tank Cooler

H level: 6.7 l L level: 2.8 l 38 l

Ambra Agriflu - OT

Travel motor Upper rollers Ambra HYPOIDE 90 Idel wheels Attachment and dozer pin Swing cylinder pin Slewing bearing Ambra GRS PLUS Idler adjuster Operating lever and pedal

1.6 l Total q.ty 4.6 l 0.7 l X 2 45 cc X 2 80 cc X 2

Specifications

QKF 583/HD

API CH4 ACEA E5 QFK 583/HD EN590 NH 900 C ASTM D 3306 Type 1 API GL5 NH 520 A

20 - places 1 - place 2 - place

NLGI 2 QFK 586/GR

When required

Rotation gear

MG 2

1 - place

Air conditioner Compressor

R134A Sanden SP-10

700 g 120 cc

NLGI 2 QFK 586/GR

(*) The systems are filled with the products indicated with the asterisk. NOTE: USE OF BIO-DEGRADABLE OILS When you use bio-degradable oil, please refer to following: •

there are two types of bio-degradable oil available: vegetable-based and synthetic-based. We recommend using synthetic oils, because vegetable ones have a maximum operating temperature of 80 °C. For this reason, the degradation of vegetable-based oil occurs more rapidly, and they have a reduced service life;

do not mix Bio-oil with original factory-filled mineral oil; in case it is necessary to use Bio-oil, flush the hydraulic system that was filled with bio-oil three times;

if you use Bio-oil, the performance of the rotation brake and that of the parking/travel brake will be reduced, because of the lower friction factor of Bio-oil compared to that of mineral oil;

USE OF COOLANT •

There are two types of coolantdepending on the corrosion inhibitors base: ORGANIC-base and INORGANICbase.

Mini excavators is ORGANIC-base type factory filled.

Both type can be used, BUT THEY CANNOT BE MIXED. Flush the cooling system before change coolant type.

2-13