2.3 Lubricating greases Requirements The MTU conditions for lubricating-grease approval are specified in the MTU Factory Standard MTL 5050, which can be ordered under this reference number. Grease manufacturers are notified in writing if their product is approved by MTU.
Lubricating greases for general applications Lithium-saponified greases are to be used for all lubrication points with the exception of: • Emergency-air shutoff flaps fitted between turbocharger and intercooler (see Special-purpose lubricants) • Coupling internal centering
Lubricating greases for applications at high temperatures High-temperature grease (up to 250 °C) must be used for emergency-air shutoff flaps located between turbocharger and intercooler: • Aero Shell Grease 15 • Optimol Inertox Medium General purpose greases suffice for emergency-air shutoff flaps located before the turbocharger or after the intercooler.
Greases for internal centerings of couplings Greases for internal centerings: • Esso Unirex N3 (stable up to approx. 160 °C)
Special-purpose lubricants Oil for turbochargers Exhaust turbochargers with integrated oil supply are generally connected to the engine oil system. For ABB turbochargers which are not connected to the engine lube oil system, mineral-based turbine oils with viscosity grade ISO-VG 68 must be used.
Lubricating greases for curved tooth couplings Depending on the application, the following lubricants have been approved for curved tooth couplings: • - Klüber: Structovis BHD MF (highly viscous lubricating oil) • - Klüber: Klüberplex GE11–680 (adhesive transmission lubricant)
TIM-ID: 0000018561 - 001
Guidelines on use and service life are contained in the relevant Operating Instructions and Maintenance Schedules.
A001061/37E 2016-12 | Lubricants for Four-Cycle Engines | 17