Komatsu PC78UU-6, PC78US-6 Excavator Shop Manual - PDF DOWNLOAD

Page 534

Q Q Q Q Q Q Q Q Q Q Q Q Q Q — — — Q — — — Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q —

— —

— —

PC78US-6 —

— —

q q

E40

q q

q q

q q

q q q q

q q

q q E41

401 402 404 405 407 408 421 422 423 424 425 426 431 435 1023

1021 1026 1060

CC- C- CC- C- C- C- C- C- C- Nor 14 C-15 16 17 18 C-19 20 21 22 23 24 25 26 mal — — — — — — — — — — — —

: Items that can only be checked by monitoring

— — — — — — — — F-3 F-4 F-2 F-1 F-7 F-5 F-6 — — — — — F-8 —

Offset LEFT EPC current output

Arm IN EPC current output

Boom RAISE EPC current output

TVC-EPC current output

Offset boom sensor voltage input

Arm angle sensor voltage input

Boom angle sensor voltage input

Engine speed input

Emergency work equipment operation switch input (3)

ATT selection

Model selection and UU/US selection cod

2nd travel speed selection (4)

Self-diagnosis Display By Controller

Swing holding brake (1)

Hydraulic Switch

PPC main pressure (2)

Travel speed selector pedal switch input (4)

Deceleration switch signal input (1)

Air compressor signal input (3)

Swing (4)

Travel (3)

Arm LOWER (5)

Boom RAISE (6)

When emergency stop is applied (Interference prevention)

Disconnection in PPC main pressure solenoid system

Disconnection in offset boom LEFT EPC solenoid system

Short circuit in offset boom LEFT EPC solenoid system

Disconnection in arm IN EPC solenoid system

Short circuit in arm IN EPC solenoid system

Disconnection in boom RAISE EPC solenoid system

Short circuit in boom RAISE EPC solenoid system

Disconnection on power supply side of offset boom angle sensor/Short circuit or disconnection of signal line

Disconnection on power supply side of arm angle sensor/Short circuit or disconnection of signal line Disconnection on GND side of offset boom angle sensor

Disconnection on GND side of arm angle sensor

Disconnection on power supply side of boom angle sensor/Short circuit or disconnection of signal line

Disconnection on GND side of boom angle sensor

TROUBLESHOOTING JUDGEMENT TABLE FOR CONTROLLER (PUMP CONTROL SYSTEM) AND HYDRAULIC EQUIPMENT

State of Solenoid

Items Checked By Monitoring

q q q q q q Diagnosis code displayed when trouble is not detected by monitoring

Monitoring Code

— — — — — — — — 1020 1026 1010 1030 1032 1031 1050 1051 1052 1053

q q C-14 – C-20

C-26

H-1

q q H-3

H-2

H-7

q q H-10

H-8

H-12

H-11

q q H-14

C-39,H-28

H-26

C-38,H-34 H-33

H-39

q

C-27 —

q

q

C-28

C-29

C-30

Q

C-31

C-32

q q

C-33

C-34

C-35

q

C-36

C-37

q : Items corresponding to service codes

20-357