Operation – Starting the engine 4.

Turn the ignition key to position “I”. ð The oil pressure control light (red) lights up.

B-ELE-0081

Fig. 48 5.

If the engine control light (yellow) also flashes, evaluate the flashing interval and perform troubleshooting Ä Chapter 9.5 ‘Engine control light’ on page 114.

B-695-0102

Fig. 49 6. The starter switch is designed with a re-start lock. The ignition key must first be turned back to position “0” before a new starting attempt can be made.

B-ELE-0082

Fig. 50

NOTICE! Components may get damaged! – Starting attempts should not exceed 30 seconds uninterrupted or max. 3 times for 10 seconds. Then allow the starter to cool down to ambient temperature. – If the engine has not started after these attempts, determine the cause. Turn the ignition key to position “II”. ð The starter cranks the engine. The oil pressure control light goes out. NOTICE! Danger of engine damage! – Warm up engine for a short while before starting work. Do not operate the engine immediately under full load.