Deutz TD 3.6 L4 TCD 3.6 L4 Operation Manual

Page 52

OBJ_DOKU-37812-001.fm Seite 52 Donnerstag, 17. Oktober 2013 12:24 12

Servicing and maintenance work

6

Regulations for working on the intake system

Suction system 1

Do not work when the engine is running!

5

Renewing the safety cartridge of the dry air filter

2

Pay attention to utmost cleanliness when working on the intake system, close intake openings if necessary. Dispose of old filter elements properly.

4

3

Never clean the safety cartridge (4). ● Renew safety cartridge (4) according to the interval in the maintenance schedule ● To do this: – Unscrew hexagon nut (5), pull out safety cartridge (4). – Insert new safety cartridge, screw on hexagonal nut. ● Insert filter element (3), mount hood (2) and fix with clamping yoke (1).

Maintaining the dry air filter Do not clean the filter element (3) with petrol or hot liquids! Renew damaged filter elements. ● Maintain the filter element (3) according to the interval in the maintenance schedule ● Lift up the clamping yoke (1). ● Remove the filter hood (2) and pull out the filter element (3). ● Filter element (3): – blow out with dry compressed air (max. 5 bar) from the inside to the outside if soiling is only slight, – renew if heavily soiled.

52