SYSTEM ADJUSTMENTS 3. S-15G Screen Layout:

S-15G Screen Data Stream:

Length of Data Stream:

Must be scrolling if properly connected to ECU and key switch set to run position. If this value is not running (increasing in value) this indi cates the diagnostic cables are either not connected properly or no power is being supplied to the engine management system. Typically 91 bytes

Analog Sensors: Pedal Angle Manifold Press. Engine Temp. Oxygen Volt. Battery Volt.

0-255 Units (Typically range, 45-195 units) 36-38 kPa at no load idle to 100 kPa at full load governed speed Current value, in Deg C Displays oxy sensor voltage normal range 0.10 - .85 volt(s) Approximately 14.5v when charging

Running Parameters: Engine Speed Selected Speed Mode

Actuator Power LP Lockout Dashlight

Current value Design speed for system based on pedal position 0 Standby 1 Cranking 2 Idle 4 Normal 6 Over speed shutoff Throttle valve opening power 0-250 units 0 off, 1 on 0 off, 1 on (see "D" screen if 1 is displayed during running mode, check engine light should be displayed) 54