Umbrella Lock is active here and X shlds to the left. #123 ULOCK > 6 More Umbrella Lock is active here and X shlds to the right. #123 ULOCK !!! Umbrella Lock is active; this is the center shield. #123 ULOCK Overlap This shield is in two umbrella lock zones; zones cannot be cleared or moved from this shield. #123 Maint. Lock !!! Maintenance Lock is active, centered on this shield. #123 Maint. Lock # Maintenance Lock is active, started & centered from the indicated shield. #123 Sol Driver Error Solenoid driver has indicated a fault. Clear Solenoid Driver error to correct using Ekey and Enter. If it happens again, replace solenoid driver, cable or PMC-R. #123 No Solenoid Drvr No solenoid driver detected! Connect solenoid driver to clear this display. If one is connected, replace cable, driver, or PMC-R. #123 Stuck Key! A key is stuck on PMC-R keyboard. Replace PMC-R. #123 Soft Locked! Because a neighbor shield lockout button is pressed, this shield is soft locked - not allowed to activate any solenoids. #123 LOCKED Large black lockout button is pressed on this PMC-R. No functions can occur on this shield; no functions are allowed on neighbor shields. #123 QUICKSTOP #100 Large red quickstop button is pressed somewhere on face. No shield functions are allowed until button is pulled back out. #123 ! SLAVE ! - ##122 This shield is in slave mode - being controlled by the indicated shield. #123 LockPush 30s 133