CAT Roof Support BMA Shield PMC-R Operating Manual - PDF DOWNLOAD

Page 66

BMA Shield PMC-R Operating Manual

Minimum height dump over-ride If the Motion Monitoring Global protection is switched ON (MotionMonitor glb = 2) and a shield reaches the MinHei.Dump limit the dump valve will be de-energized. A facewide message will have occurred ‘‘MinHei.Dump #ShieldNo’. Both neighbours of the lowered shield will show ‘MinHeight_Oride (ENTER)’ in the default display. Pressing will override the dump command and energizes the dump valve again. The facewide messages changes from ‘MinHei.Dump #ShieldNo’ to ‘MinHei.Oride #ShieldNo.’. It will now be possible to set the shield that is below the defined dump limit.

EM027362-01

Page 66 of 74