CAT Roof Support BMA Shield PMC-R Operating Manual - PDF DOWNLOAD

Page 39

BMA Shield PMC-R Operating Manual

Initiate an ASQ Batch WARNING Mine safety procedures in regards to shield movement MUST be observed.

1.

Press

2.

To select the neighbour group of shields you want the function to operate, press or

3.

to select the Shield advance operation in Batch group.

.

The PMC-R display shows: Operating mode

BA: SEQU r2

Direction

41

c100 s100

>

37

SA-Idle

4.

Pressing RABB.

, the operator can toggle between the operating modes SEQ, RAN and

5.

Pressing will operate.

, the operator can toggle between the directions that the group function

6.

Press

to initiate the Batch Shield advance sequence.

In the above example a Batch Shield advance has been selected from shield 36. The Shields will advance in sequential order starting with No.41. Pressing the stop key, at any time will stop the batch Shield advance and any other automatic functions on the face including SRB.