1 minute read
Initiate the trigger for the Main to Tail TCC sequence
During SRB operations a trigger is available to initiate a free running automatic TCC sequence from the Maingate to the Tailgate. For this trigger to be available the following conditions must be met. • SRB is active • The SRB Tail to Main TCC sequence has completed or the Shearer has passed the S_dist Main trigger point on the Main to Tail sequence. • Within 10 minutes of the trigger becoming available or the shearer enters the Tailgate.
Or,
• An SRB newstart is initiated in the Main to tail direction. • Shearer leading drum is within S_offset distance of No.3 shield.
1. When the trigger is available the key will flash on all MG 3-leg shields.
2. Press the key.
3. Press the key.
The PMCR display will now display,
SRB TCC trigger (P)
r2 c100 s100 SA-Idle
4. Now press the key to start the Main to Tail TCC.