1 minute read
Initiate an SRB restart
When SRB is suspended using the key it is possible to resume SRB operations from where they were suspended. This feature is useful when the operator has to manually operate the shearer outside of the normal cutting sequence. E.g. reverse the shearer.
1. SRB can only be ‘Restarted’ from a group of supports near the shearer, indicated by
a flashing and keys LED’s.
2. The SRB sequence can be ‘Restarted’ by pressing , then and then
WARNING
When SRB is re-started shields will commence to advance or push the conveyor where the sequence was suspended regardless of the shied operations distance from the shearer. S_Offset is not used for an SRB restart.