
1 minute read
Initiate a remote Shield for slave operation
WARNING
Mine safety procedures in regards to shield movement MUST be observed. This feature allows operation of a Shield up to 5 Shields away from the operator using the adjacent control functions of the PMC-R.
1. To operate an auxiliary function an adjacent Shield must be selected pressing the
or keys.
2. If remote operation is enabled then the desired remote shield may be selected by
pressing . 3. The display on the master PMCR changes to:
4. Press the key to decrease and the key to increase the distance to the shield you want to operate (adjacent shield, up to 5=5th adjacent shield).
In this example the has been pressed twice. (Assuming NbManDist = 0)
5. Finally to select the shield press the key.
In this example, the shield that is 2 shields away in the direction initially selected by the
or key will be placed into slave mode. The beeper will be heard and the shield can be operated from the Master PMCR.