Changing Parameters
Many of the menu displays in the PMC-R menu are adjustable parameters that affect the way the Shields operate. There are two types of parameters in the PMC-R program. • Numeric parameters (those preceded by a * symbol) • Text parameters Parameters can be changed following the procedures below.
Numeric parameters can be changed by
1. Navigate to the menu item you wish to change
2. Press .
3. If the parameter is password protected the screen will show PASSWORD?
4. Enter the password with the Numeric keys and press .
5. Press the Numeric keys to enter the new value for the parameter
6. Press to save the new parameter.
Text parameters can be changed by
1. Navigate to the menu item you wish to change
2. Press or for some parameters maybe the if prompted.
3. If the parameter is password protected the screen will show PASSWORD?
4. Enter the password with the Numeric keys and press .
5. Press to scroll through the parameter options to the desired setting
WARNING
Many of the parameters are password protected from view and to prevent inadvertent altering of parameters. Changing too many parameters could result in damage to equipment and / or danger to personnel.