AC Parameters
• Engine Oil Temperature • Engine Fuel Temperature
ENGINE SCREEN 8 †
• Fuel Pressure • Crankcase Pressure • Boost Pressure
ENGINE SCREEN 9 †
• Oil Filter Differential Pressure • Fuel Filter Differential Pressure
ENGINE SCREEN 10 †
• Air Filter Differential Pressure
ENGINE SCREEN 11 †
• Total Fuel Consumption • Instantaneous Fuel Consumption
AC PARAMETERS
AC OVERVIEW SCREEN
• Average Line-Line AC Voltage • Average Current • AC Frequency • Power Factor (EMCP 3.2-3.3 only)
• Power Factor Lead/Lag status (EMCP 3.2-3.3 only) • Total Generator Real Power – kW – (EMCP 3.2-3.3 only) • Percent Real Power – as a percent of Generator Rated Power setpoint – (EMCP 3.23.3 only)
AC SCREEN 1
• Line-Line Voltages: A-B, B-C, C-A • Phase Currents: A, B, C • AC Frequency
AC SCREEN 2
• Line-Neutral Voltages: A-N, B-N, C-N • Phase Currents: A, B, C (same as AC Screen 1) • AC Frequency (same as AC Screen 1)
AC SCREEN 3 (EMCP 3.2-3.3 ONLY)
• Per Phase Generator Real Power: A, B, C • Per Phase Generator Apparent Power: A, B, C • Per Phase Generator Reactive Power: A, B, C
AC SCREEN 4 (EMCP 3.2-3.3 ONLY)
• Per Phase Generator Real Power: A, B, C (same as AC Screen 3) • Per Phase Generator Apparent Power: A, B, C (same as AC Screen 3)
† Only shown if these parameters are supported by the engine ECM, and if the EMCP 3 setpoint Engine J1939 Support is set to Enhanced J1939.
• Per Phase Power Factor: A, B, C
AC SCREEN 5 (EMCP 3.2-3.3 ONLY)
• Total Generator Real Power (same as AC Overview Screen) • Percent Real Power (as a percent of Generator Rated Power setpoint) • Total Generator Apparent Power • Percent Apparent Power (as a percent of Generator Rated Apparent Power setpoint) • Total Generator Reactive Power • Percent Reactive Power (as a percent of the rated reactive power, as calculated by using the other two rated power setpoints and the power triangle: kVAr = ( )kVA 2 − (kW )

2 )
AC SCREEN 6 (EMCP 3.2-3.3 ONLY)
• Generator Real Energy produced since last meter reset • Generator Reactive Energy produced since last meter reset • (option to reset energy meters)

AC SCREEN 7
• Average Line-Line AC Voltage (same as AC Overview Screen) • Average Line-Neutral AC Voltage • Power Factor (EMCP 3.2-3.3 only) (same as AC Overview Screen) • Power Factor Lead/Lag status (EMCP 3.2-3.3 only) (same as AC Overview Screen)
AC SCREEN 8 (EMCP 3.3 ONLY) ‡
• Generator Front Bearing Temperature • Generator Rear Bearing Temperature
AC SCREEN 9 (EMCP 3.3 ONLY) ‡
• Generator Phase A Winding Temperature • Generator Phase B Winding Temperature • Generator Phase C Winding Temperature
AC SCREEN 10 (EMCP 3.3 ONLY) ‡
• Generator Excitation Field Voltage • Generator Excitation Field Current
4.2 SETTING USER PREFERENCES
The EMCP 3 GSC display can be used for monitoring the generator status, viewing and resetting events, and configuring setpoints. There are several preferences to alter how you view the data on the display. These include: display contrast, units used to display pressure, units used to display temperature, units used to display volume (EMCP 3.3 only), and display

‡ Only shown on the EMCP 3.3, and only if an optional Thermocouple or RTD module is connected and configured for one of these parameters.