Section V - Integrated Dryer (option) Troubleshooting

Notice! The alarm indication light (red) signifies the refrigerant compressor is not running. The reasons can be: •Low suction pressure

The following conditions can cause abnormal operation or malfunction of the air dryer • High inlet air temperatures

•High discharge pressure

• Dirty condenser

•Electrical problems

• Low ambient temperatures

•Loss of refrigerant •Dirty condenser

• Malfunctioning automatic drains at aftercooler, or dryer

•Leaking evaporator, etc.

• Refrigerant overcharge

Refer to the Troubleshooting section for problem analysis and remedy. Call the factory if further assistance is required.

• Leaky evaporator • Electrical power supply more than ±10% of the rated voltage • Low inlet air pressures • High ambient temperatures • Compressed air flow greater than rated capacity • Undersized fuses • Refrigerant undercharge If any of these symptoms are noticed, refer to Section VIII - Troubleshooting.