JCB TM320 Telescopic Wheeled Loader Service Repair Manual – PDF Download

Page 643

Section M - Network Systems Electronic Fault Codes Electronic Monitoring System ECU Fault Codes Fault Code

Description

Fault Code

Description

U040B-97

CAN communication error: EGR obstruction

P029A-00

U040B-98

CAN communication error: EGR overtemperature

U040B-4B

CAN communication error: EGR overtemperature

Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Max APC raw trim at medium rail pressure

P029B-00

P1509-00

CAN communication Error on TSC

Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at high rail pressure

P029B-00

Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at low rail pressure

P029B-00

Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at medium rail pressure

P0264-1B

Injector and wiring harness resistance too high/low (inj 1)

P0265-1A

Injector and wiring harness resistance drop (Inj 1)

P0264-1A

Injector and wiring harness resistance too high/low (inj 1)

P0202-00

Injector in Cylinder 2 Short Circuit HSD to LSD

P029F-00

Fault which is set when the Injector 2 absolute MDP value is below a calibrated threshold

P1106-00

Fault which is set when no MDP updates occur on Injector 2 due to environmental conditions (as defined by the update strategy)

P1107-00

Fault which is set when no MDP updates occur on Injector 2 due to a fault within the update strategy

P029E-00

Injector drift fault detection on Injector 1. Fault which is set when the Injector 1 MDP trim exceeds the maximum calibrated threshold limit. Maximum APC raw trim at high rail pressure

U010C-88 U040D-00 U040D-96

CAN communication error: VGT hardware

U040D-97 U040D-98

CAN communication error: VGT overtemperature

U040D-9A U040D-54

CAN communication error: VGT spanlearn

P0261-1B

Injector and wiring harness resistance too high/low (inj 2)

P0262-1A

Injector and wiring harness resistance drop (Inj 2)

P0261-1A

Injector and wiring harness resistance too high/low (inj 2)

P0201-00

Injector in Cylinder 1 Short Circuit HSD to LSD

P029B-00

Fault which is set when the Injector 3 absolute MDP value is below a calibrated threshold

P1104-00

P1105-00

P029A-00

P029A-00

M-20

Fault which is set when no MDP updates occur on Injector 3 due to environmental conditions (as defined by the update strategy) Fault which is set when no MDP updates occur on Injector 3 due to a fault within the update strategy Injector drift fault detection on Injector 3. Fault which is set when the Injector 3 MDP trim exceeds the maximum calibrated threshold limit. Maximum APC raw trim at high rail pressure Injector drift fault detection on Injector 2. Fault which is set when the Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Max APC raw trim at low rail pressure

9813/4700-1

M-20


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
JCB TM320 Telescopic Wheeled Loader Service Repair Manual – PDF Download by www.heydownloads.com - Issuu