Section M - Network Systems Electronic Fault Codes Electronic Monitoring System ECU Fault Codes Fault Code
Description
Fault Code
Description
U040B-97
CAN communication error: EGR obstruction
P029A-00
U040B-98
CAN communication error: EGR overtemperature
U040B-4B
CAN communication error: EGR overtemperature
Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Max APC raw trim at medium rail pressure
P029B-00
P1509-00
CAN communication Error on TSC
Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at high rail pressure
P029B-00
Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at low rail pressure
P029B-00
Injector drift fault detection on Injector 2. Fault which is set when Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Min APC raw trim at medium rail pressure
P0264-1B
Injector and wiring harness resistance too high/low (inj 1)
P0265-1A
Injector and wiring harness resistance drop (Inj 1)
P0264-1A
Injector and wiring harness resistance too high/low (inj 1)
P0202-00
Injector in Cylinder 2 Short Circuit HSD to LSD
P029F-00
Fault which is set when the Injector 2 absolute MDP value is below a calibrated threshold
P1106-00
Fault which is set when no MDP updates occur on Injector 2 due to environmental conditions (as defined by the update strategy)
P1107-00
Fault which is set when no MDP updates occur on Injector 2 due to a fault within the update strategy
P029E-00
Injector drift fault detection on Injector 1. Fault which is set when the Injector 1 MDP trim exceeds the maximum calibrated threshold limit. Maximum APC raw trim at high rail pressure
U010C-88 U040D-00 U040D-96
CAN communication error: VGT hardware
U040D-97 U040D-98
CAN communication error: VGT overtemperature
U040D-9A U040D-54
CAN communication error: VGT spanlearn
P0261-1B
Injector and wiring harness resistance too high/low (inj 2)
P0262-1A
Injector and wiring harness resistance drop (Inj 2)
P0261-1A
Injector and wiring harness resistance too high/low (inj 2)
P0201-00
Injector in Cylinder 1 Short Circuit HSD to LSD
P029B-00
Fault which is set when the Injector 3 absolute MDP value is below a calibrated threshold
P1104-00
P1105-00
P029A-00
P029A-00
M-20
Fault which is set when no MDP updates occur on Injector 3 due to environmental conditions (as defined by the update strategy) Fault which is set when no MDP updates occur on Injector 3 due to a fault within the update strategy Injector drift fault detection on Injector 3. Fault which is set when the Injector 3 MDP trim exceeds the maximum calibrated threshold limit. Maximum APC raw trim at high rail pressure Injector drift fault detection on Injector 2. Fault which is set when the Injector 2 MDP trim exceeds the maximum calibrated threshold limit. Max APC raw trim at low rail pressure
9813/4700-1
M-20