Dirk India Private Limited Factory:Gut No 348, Behind NTPS, Eklahare, Nashik-422105 www.ambujahirise.in
Ambuja HiRise Cement Specimen Test Certificate
Test No.
Test
Unit
IS 1489 (Part1): 1991 requirements
Ambuja HiRise Typical Test Results
Chemical Requirements 1
Loss on Ignition, max
%
5
0.76
2
Magneisa, max
%
6
2.52
3
Sulphuric Anhydride, max
%
3
1.68
4
Insoluble material, max
%
X + 4.0 (100 - X)
32.9
100
5
Chloride, max
%
X = declared % of fly ash 0.1
0.01
m2/kg
300
366.20
Physical Requirements 1
Fineness , min
2
Normal Consistency
3
Setting Time a. Initial, min
%
minutes
30
115
600
225
mm
10
1.00
%
0.8
0.03
b. Final, max 4
Soundness a. Le- Chatelier Expansion, max b. Autoclave Expansion, max
5
6
31.20
Compressive strength
%
0.73
a. 72 +/- 1 hr
Mpa
16
33.90
b. 168 +/- 2hr
MPa
22
46.10
c. 672 +/- 4hr
MPa
33
62.80
%
0.15
0.08
Drying shrinkage, max
A.R.Yadav Q.C.Department
Regd Office:10,India House,Geetanjali Colony,Indira Nagar,Nashik-422009 Phone:(0253) 2322816, 2326679 Fax:(0253) 2326678