SCOPE

ThisAgrémentrelatestoSuperbead33+,areducedCO2emissions(CO2e)CavityWallInsulation(CWI)hereinaftertheSystem.TheSystemisforuseas injectedCWIandimprovesthethermalinsulationofexternalclosedconstructioncavitywallswithmasonryinnerandouterleaves(wheremasonryincludesclay andcalciumsilicatebricks,concreteblocksandnaturalandreconstitutedstoneblocks),masonrypartywallsorexternalmasonryouterleafwithsheathedloadbearingtimberframedstudinternalwalls.TheSystemisforfillingcavitywallsinexistingornew,residentialandnon-residentialbuildingsintheUKandIreland.

DESCRIPTION

TheSystemconsistsofagrey,spherical,closedcell,carbonenhancedexpandedpolystyrene(EPS)beadmanufacturedwithapentaneexpandingagentin accordancewithdraftBSEN16809-1.TheSystemisindependentlyauditedandcertifiedbyREDcerttotheREDcert2schemetoensurethemanufacturing processusesverifiedbiofuelsthatleadto80%lessCO2ethanthegreyEPSbeadproducedusingconventionalfuels.Awater-baseddispersionofacryliccopolymeremulsion,air-drying,contactbondingadhesiveissimultaneouslyinjectedwiththeEPSbeadswithappropriateinjectionmachinery.TheEPSbeadsare coatedwiththebondingadhesiveintheinjectionguntobondandsettheEPSbeadsandmaketheEPSbeadfillstableoverthelong-term.TheSystemis injectedthroughaseriesofholes,drilledinapredeterminedpattern.LayersofEPSbeadsarebuiltupuntilthewholecavitywallisfullyfilledinaccordancewith BSEN16809-2.

SYSTEMILLUSTRATION

THIRD-PARTYACCEPTANCE

NHBC/REDcert-Fordetailedinformationseesection3.3(Third-Partyacceptance)

STATEMENT

ItistheopinionofKiwaLtd.thattheSystemisfitforitsintendeduse,provideditisspecified,installedandusedinaccordancewiththisAgrément.

IssueDate:July2022 ©2022KiwaLtd. Page1of14
Unit5PrimeParkWay PrimeEnterprisePark Derby DE13QB
BAW-22-255-S-A-UK BDAAgrément® Superbead33+ ReducedCO2eInjectedBonded BeadCavityWallInsulation EnergystoreLtd. 21-23ShoreRoad Holywood BT189HX T:+44(0)2890301500 E:info@energystoreltd.com W:www.energystoreltd.com
CraigDevine OperationsManager,BuildingProducts AlpheoMlothaCEngFIMMMMBA TechnicalManager,BuildingProducts

SUMMARYOFAGRÉMENT

ThisdocumentprovidesindependentinformationtoSpecifiers,buildingcontrolpersonnel,contractors,installersandotherconstructionindustryprofessionals consideringthefitnessfortheintendeduseoftheSystem.ThisAgrémentcoversthefollowing:

Conditionsofuse;

InitialFactoryProductionControl,QualityManagementSystemandtheAnnualVerificationprocedure; PointsofattentionfortheSpecifierandexamplesofdetails; Installation;

IndependentlyassessedSystemcharacteristicsandotherinformation; CompliancewithnationalBuildingRegulations,otherregulatoryrequirementsandThird-Partyacceptance; Sources,includingcodesofpractice,testandcalculationreports.

MAJORPOINTSOFASSESSMENT

Adequacyoffill-walls,includingpartiallyfilledcavitywalls,canbefullyfilledsufficientlywiththeSystem(seesection2.1.10)

Thermalinsulationproperties-theSystemimprovesthethermalinsulationofthewallstructure(seesection2.1.10).

Condensationrisk-theSystemcancontributetolimitingtheriskofinterstitialandsurfacecondensation(seesection2.1.10).

Resistancetoprecipitationincludingwind-drivenrainpenetration-theSystemwillresistthetransferofwateracrossthecavitytotheinnerleaf(see section2.1.10).

Resistancetogroundmoisture-theSystemdoesnotabsorbwaterbycapillaryactionandmaythereforebeusedinsituationswhereitbridgesthedamp proofcourse(DPC)oftheinnerandouterleafofcavitywalls(seesection2.1.10).

Behaviourinrelationtofire-theSystemisclassifiedasEuropeanClassificationE,inaccordancewithBSEN13501-1(seesection2.1.10).

Durability-theSystemisstable,rot-proof,waterresistantanddurableandwillhaveaservicelifeequivalenttothatofthelifeofthecavitywallinwhichitis installed(seesection2.1.8).

CEmarking-theproductmanufacturershavetakenresponsibilityforCEmarkingoftheproductsusedintheSysteminaccordancewithallrelevant harmonisedEuropeanProductStandards.Anasterisk(*)appearinginthisAgrémentindicatesthatdatashownisgivenintherelevantproductmanufacturers DeclarationofPerformance(DoP).

©2022KiwaLtd.

IssueDate:July2022
Page2of14
CONTENTS Chapter1-Generalconsiderations 1.1-Conditionsofuse 1.2-InitialFactoryProductionControl(FPC) 1.3-QualityManagementSystem(QMS) 1.4-Annualverificationprocedure-continuoussurveillance Chapter2-Technicalassessment 2.1-PointsofattentiontotheSpecifier 2.2-Examplesofdetails 2.3-Installation 2.4-IndependentlyassessedSystemcharacteristics 2.5-Ancillaryitems Chapter3-CDM,nationalBuildingRegulationsandThird-Partyacceptance 3.1-TheConstruction(DesignandManagement)Regulations2015andTheConstruction(DesignandManagement)Regulations(NorthernIreland)2016 3.2-NationalBuildingRegulations 33-Third-Partyacceptance Chapter4-Sources Chapter5-Amendmenthistory

CHAPTER1-GENERALCONSIDERATIONS

1.1-CONDITIONSOFUSE

1.1.1Designconsiderations

Seesection2.1.

1.1.2Application

TheassessmentoftheSystemrelatestoitsuseinaccordancewiththisAgrémentandtheAgrémentholdersrequirements.

1.1.3Assessment

KiwaLtd.hasassessedtheSystemincombinationwithitsrelevantDoPs,testreports,technicalliteratureandfactoryandsitevisitsAlso,theNHBCStandards havebeentakenintoconsiderationFactoryProductionControlhasbeenassessed.

1.1.4Installationsupervision

TheAgrémentholderonlymanufacturesandsuppliestheSystem.TheinstallationcompaniesaretrainedandapprovedbytheAgrémentholder.

Thequalityofinstallationandworkmanshipmustbecontrolledbyacompetentpersonwhoshallbeanemployeeoftheinstallationcompany.Installationwork shallbesubjecttotheKiwaInstallerAssessmentandSurveillanceScheme.

TheSystemshallbeinstalledstrictlyinaccordancewiththerequirementsofthisAgrément.

Seealsosection2.1.6

1.1.5Geographicalscope

ThevalidityofthisdocumentislimitedtoEngland,Wales,Scotland,NorthernIrelandandIreland,withdueregardtochapter3ofthisAgrément(CDM,national BuildingRegulationsandThird-PartyAcceptance)

1.1.6Validity

ThepurposeofthisBDAAgrément®istoprovideforwell-foundedconfidencetoapplytheSystemwithintheScopedescribedThevalidityofthisAgrémentis threeyearsaftertheissuedate,andaspublishedonwww.kiwa.co.uk/bda.Afterthis,thevalidityofthisAgrémentcanbeextendedeverythreeyearsaftera positivereview.

1.2-INITIALFACTORYPRODUCTIONCONTROL(FPC)

KiwaLtd.hasdeterminedthattheAgrémentholderhasfulfilledallprovisionsofthespecificationsdescribedinthisAgrémentinrespectoftheSystem TheinitialFPCauditdemonstratedthattheAgrémentholderhasasatisfactoryQualityManagementSystem(QMS)andiscommittedtocontinuously improvingtheirFPCoperations.

AdetailedProductionQualitySpecification(PQS)hasbeencompiledtoensuretraceabilityandcomplianceunderthetermsofthisAgrément

1.3-QUALITYMANAGEMENTSYSTEM(QMS)

TheAgrémentholder:

o hasaneffectiveandwellmaintainedQMSinoperationwhichcoversthenecessaryclausesrequiredforBDAAgrément®

o iscommittedtocontinuallyimprovingtheirFPC,QMSandassociatedprocedures.

Documentcontrolandproductionlineproceduresweredeemedsatisfactory,withsufficientevidenceprovidedinsupportofBDAAgrément®requirements.

1.4-ANNUALVERIFICATIONPROCEDURE-CONTINUOUSSURVEILLANCE

TodemonstratethattheFPCisinconformitywiththerequirementsofthetechnicalspecificationdescribedinthisAgrément,thecontinuoussurveillance, assessmentandapprovaloftheFPCwillbedoneatafrequencyofnotlessthanonceperyearbyKiwaLtd.

IssueDate:July2022

©2022KiwaLtd.

Page3of14

CHAPTER2-TECHNICALASSESSMENT

2.1-POINTSOFATTENTIONTOTHESPECIFIER

2.1.1Designresponsibility

TheAgrémentholderreviewsalldesignssubmittedandoffersdesignadviceandguidancetoensureacompliantfinalprojectspecificdesign.

2.1.2Appliedbuildingphysics(heat,airmoisture)

ThephysicalbehaviourofthewallincorporatingtheSystemshallbeverifiedassuitablebyacompetentspecialist,whocanbeeitheraqualifiedemployeeofthe Agrémentholderoraqualifiedconsultant.TheSpecialistwillcheckthephysicalbehaviouroftheexternalwalldesignandifnecessarycanofferadvicein respectofimprovementstoachievethefinalspecification.AcondensationriskanalysisshallbecompletedatdesignstageinaccordancewithBS5250.Itis recommendedthattheSpecialistco-operatescloselywiththeAgrémentholder

2.1.3Generaldesignconsiderations

TheSystemmaybeusedinwallsupto12minheight(orabovewheretheAgrémentholderhasissuedasuitablewaiver),innon-residentialbuildingsorwhen installedinacavityconstructioncomprisingtwomasonryleaves,eachatleast75mmthick,subjecttoreactiontofireheightrestrictionsinaccordancewith nationalBuildingRegulations

Considerationshallbegiventothelocalwind-drivenrainindexinaccordancewithBS8104andthesiteexposurezoneinaccordancewithPD6697The Systemshallnotbeusedinareasofverysevereexposuretowind-drivenrainwherefair-facedmasonryistheexternalcladding

Formasonrywalls,minimumcavitywidthstobefilled:

forexistingbuildingsmustbenolessthan40mm; fornewbuildingsmustcomplywiththerelevantnationalBuildingRegulations; onnewbuildingswhereNHBCTechnicalStandardsapplymustbenolessthan50mm,asdefinedinNHBCStandardsChapter6.1.

Fortimberframedwalls:

theminimumcavitywidthtobefilledmustbenolessthan50mm;

the50mmcavitybetweentheinnerfaceoftheexternalmasonrywallandouterfaceofthetimberframedinnerleafmustbefreefromanyobstruction (includinginsulation)toensurethatthereisnotabridgethatallowswatertocrossthecavityfromtheexternalmasonrywalltothetimberframedinnerleaf Alappedandsealedwaterproofmembranemustbeappliedtotheouterfaceofthetimberframedinnerleaf,tofurtherpreventriskofwaterexposuretothe timber;

thetimberframedwallstudcavitywilltypicallybeineither400mmor600mmwidesectionsbetweensolidtimberstudsorjoists,withatypicalvoiddepthof 140mm;

timberframedwallsmayhaveaseparateservicecavityforelectricalwiring,howeverelectricalcablesmaybelaidinthesamecavityastheSystem.Where thisisthecase,carefulconsiderationshouldbegiventoensurethatelectricalwiringmustbeinstalledinconduittoseparateitfromtheSystemandallow easieraccessforfuturework;

avapourcontrollayer(hereinafterVCL)mustbeappliedontheinternalfaceofthetimberframedinnerleaftoensurethatthemoisturecontentofthe timberiskeptatorbelow20%,andtoensuretheairtightnessofthebuilding.

2.1.4Projectspecificdesignconsiderations

Pre-installationsurveyrequirements

Apre-installationsurveymustbeundertakentotheAgrémentholdersspecification;itisamandatoryrequirementtouseatapemeasureandborescope,to assessthewidthofthecavityandtoensureaclearvoidexists.Thefindingsofthissurveymustberecordedonasurveyorsreport.Selectionofanappropriate drillingpatternmusttakeintoconsiderationthenatureofthebuildinganditsconstruction.

2.1.5Permittedapplications

OnlyapplicationsdesignedaccordingtothisAgrémentareallowed,ineachcasetheSpecifiermustcooperatecloselywiththeAgrémentholder.

Existingbuildings:

theSystemshallbespecifiedtocomplywiththerequirementsofthenationalBuildingRegulations

Newbuildings:

externalmasonrywallsshallbeconstructedinaccordancewiththenationalBuildingRegulations; whererequired,dueconsiderationmustbegiventoNHBCStandards;

installationoftheSystemmustnotbeundertakenuntilthecavityisweathertight,i.e.theroofisinplaceandthewindowanddooropeningsaresealed. Partialfill(residualcavitiesandomittedareas);whereverpracticableandpossible,allofthecavityspacefromgroundleveltotherooforgablecopingsshould befilled,withtheexceptionof:

whenasemi-detachedorterracedpropertyistobeinsulatedseparately.Inthiscaseapolypropylenecavitybrushmustbeinsertedatthelinedividingthe propertiestocontaintheinsulation.Thisbrushisleftinplaceuponcompletionoftheworks;

whenfillinguptotheundersideofahorizontalboundaryotherthantheroof,wheretheboundaryisprotectedbyacavitytrayorsimilarwaterproofbarrier; wherethewalltobeinsulatediscoveredbyawaterproofcladding,suchashungtiles,andthiscladdingeitherextendsuptotherooforisprotectedatthe topbyothermeans(suchawindowcills);

insulatingareasofthewallwhereaccessfordrillingmaybelimitedbyfeaturessuchascarportsandconservatories.Theseareasmayhoweverbe accessedusingtheenergystorethermallance;

TheNHBCdoesnotgenerallyacceptexternalmasonrywallsconstructedwithdifferenttypesofcavityinsulationwithinthewallbuildup.Installingblown insulationtonewlycompletedhomesmayinvalidateclaimsmadeagainstthenewhomewarranty.

IssueDate:July2022 ©2022KiwaLtd. Page4of14

2.1.6Installercompetencelevel

TheAgrémentholderoperatesanApprovedInstallerSchemefortheSystemunderwhichinstallersareapproved,registeredandregularlyreviewedbythe AgrémentholdertodemonstratethattheyarecompetenttocarryoutinstallationsoftheSysteminaccordancewiththisAgrément.DetailsofApprovedInstallers areavailablefromtheAgrémentholder.ApprovedInstallersarefullyresponsibleforeachinstallationoftheSystemthattheyundertake.Furthermore,installers aretobemonitoredunderanIndependent3rdPartyCWIInstallationAssessment&SurveillanceSchemeoperatedorapprovedbyKiwaLtd.

2.1.7Delivery,storageandsitehandling Seesection2.3

2.1.8Durability

Onceinstalled,theSystemisprotectedinservicefromagentsliabletocausedeteriorationandwillbeeffectiveasinsulationforthelifeofthebuildinginwhichit isinstalled.Ifitisdeemednecessaryforanyreason,theSystemcanbeextractedfromthecavityvoid

2.1.9Maintenanceandrepair

OnceinstalledstrictlyinaccordancewiththerequirementsofthisAgrément,theSystemiscontainedwithinthestructureofthewallandthereforedoesnot requiremaintenanceforaslongasthewallismaintainedinaweathertightcondition.

2.1.10PerformancefactorsinrelationtotheMajorPointsofAssessment

Adequacyoffill(usingspecifiedinstallationmachineryanddrillingpattern)

Acavitywallcanbefullyfilled(withnogapsandaconsistentdensity)withtheSystemEventhemostdifficulttofillareaofacavitywall(theareatobelocated overaconservatorywherenodrillingorinjectionispermitted)canbefilledsufficientlywiththeSystemwhenusingtheenergystorethermallanceinstallation equipmentandtechnique.ThebondingadhesiveensuresthattheSystemremainsstablewithinthecavityandhasadequateresistancetosettlement.

Thermalinsulationproperties

ForthepurposeofU-valuecalculationsandtodetermineiftherequirementsofnationalBuildingRegulationsaremet,thethermalresistanceandU-valueof cavitywallsincorporatingtheSystemshouldbecalculatedinaccordancewithBSENISO10211(takingintoconsiderationBSENISO6946,BSENISO10456, BREReport443,PAS2030andPAS2035),usingtheSystemsdeclaredthermalconductivity(D)value.

Condensationrisk

ExternalwallsincorporatingtheSystemwilladequatelylimittheriskofsurfaceandinterstitialcondensationwhendesignedinaccordancewithBS5250.

Resistancetoprecipitationincludingwind-drivenrainpenetration

AcavitywallincorporatingtheSystem,wheninstalledinaccordancewiththisAgrément,canadequatelyresistrainwaterpenetrationacrossthecavitytothe innerleaf.TheSystemdoesnotaddtotheriskofwaterpenetration.ThegapsthatnaturallyoccurbetweentheEPSbeadsallowanywatertodraindownfreely totheground,ratherthantrackacrossthecavity.

Resistancetogroundmoisture

TheSystemdoesnotabsorbwaterbycapillaryaction.TestsconfirmtheSystemwillnottransmitmoisturebycapillaryactionacrossthecavityorfrombelow damp-proofcourse(DPC)level.TheSystemcanbeusedinsituationswhereitbridgestheDPCoftheinnerandouterleaf.Dampnessfromthegroundwillnot passthroughtotheinnerleafprovidedthewalliscorrectlydetailedinaccordancewiththerequirementsofthenationalBuildingRegulations.

Behaviourinrelationtofire

TheSystemisclassifiedasEuropeanClassificationEinaccordancewithBSEN13501-1.

Fornon-residentialbuildingsinEngland,WalesandNorthernIreland,thefollowingappliesinaccordancewiththenationalBuildingRegulations:

theSystemshallnotbeusedonbuildingswithastoreyof18mormoreabovegroundlevel.RefertotherelevantnationalBuildingRegulationsfortypesof buildingsandanyexclusionsthatmayapply;

boundaryrestrictionswillapply,dependentontheexternalsurfacematerialsoftheexternalwallincorporatingtheSystem,facingtheboundary.

ForresidentialbuildingsinEngland,WalesandNorthernIreland,thefollowingappliesinaccordancewiththenationalBuildingRegulations:

theSystemisrestrictedtobuildingswithnofloormorethan11maboveground.RefertothenationalBuildingRegulationsfortypesofbuildingsandany exclusionsthatmayapply;

boundaryrestrictionswillapply,dependentontheexternalsurfacematerialsoftheexternalwallincorporatingtheSystem,facingtheboundary.

ForallbuildingsinScotland,theSystemisrestrictedtobuildingswithnofloormorethan11mabovegroundandnotlessthan1mfromtheboundary.Insuch cases,theSystemmaybeexcludedfromtheunprotectedareacalculationregardlessofopenings.RefertothenationalBuildingRegulationsfortypesof buildingsandanyexclusionsthatmayapply.

FordwellingsinIreland,theSystemshallnotbeusedonbuildingswithastoreyof15mormoreabovegroundlevel;theSystemcanbeusedwithoutany boundaryrestrictions.RefertotherelevantnationalBuildingRegulationsfortypesofbuildingsandanyexclusionthatmayapply.

ForbuildingsotherthandwellingsinIreland,theSystemshallnotbeusedonbuildingswithastoreyof18mormoreabovegroundlevel;theSystemcanbe usedwithoutanyboundaryrestrictions.RefertothenationalBuildingRegulationsfortypesofbuildingsandanyexclusionthatmayapply.

ForallbuildingsinEngland,Wales,NorthernIreland,ScotlandandIreland,theSystemisunrestrictedforuseintermsofheightabovegroundandproximitytoa boundary,provideditisinstalledinacavityconstructioncomprisingtwomasonryleaves,eachatleast75mmthick,andwithcavitiesclosedaroundopeningsin awallandatthetopofawallhead.

TheSysteminstalledinawallcomprising12mmthickOSBboard,membrane,timberstudsandnogginsand125mmthickplasterboardhasbeentestedina loadbearingtimberframedwallandachievedREI30(seeSection2.4.6).

Page5of14
IssueDate:July2022 ©2022KiwaLtd.

Toensurethatthefireintegrityofatimberframedwallismaintained,thetimberliningboardmusthavethejointsbetweentheboardsfullysealedandsupported bytimberstudworkorbattens.

Inallconstructions,cavitybarriersshallbeprovidedtocomplywiththerelevantprovisionsofthenationalBuildingRegulations.

Fordetailedconditionsofuseregardingrequirementsforsubstratefireperformance,cavityclosersandbarriers,firestoppingofservicepenetrationsand combustibilitylimitationsforothermaterialsandcomponentsusedintheoverallwallconstruction,designersshallrefertotherelevantnationalBuilding Regulations.

Proximityoffluesandappliances

Non-combustibleinsulationshallseparateorshieldtheinstalledSystemfromanyheat-emittingdevices,fixedcombustionappliances,incinerators,recessed lighting,fireplaces,chimneysorfluepipespassingthroughexternalwalls,andfromanypotentialsourceofignitionwherethetemperatureisinexcessof70°C, inaccordancewiththeprovisionsofthenationalBuildingRegulations.

2.2-EXAMPLESOFDETAILS

Page6of14
IssueDate:July2022 ©2022KiwaLtd.
Figure1-Fullfilldrillpatternformasonryproperties
IssueDate:July2022 ©2022KiwaLtd. Page7of14
Figure2-energystorethermallanceinmasonryproperties Figure3-energystorethermallancebetweenwindowsinmasonryproperties
IssueDate:July2022
Page8of14
©2022KiwaLtd.
Figure4-Partialfilldrillpatternformasonryproperties Figure5-Fullfilldrillpatternfortimberframedproperties

2.3-INSTALLATION

2.3.1Installercompetencelevel

TheAgrémentholderonlymanufacturesandsuppliestheSystem.

TheSystemshallbeinstalledstrictlyinaccordancewiththeSystemManualinstructionsoftheAgrémentholderandtherequirementsofthisAgrément.

Installationcanbeundertakenbyoperativestrainedandapprovedbytheinstallingcontractor(whomustbelongtotheKiwaInstallerAssessmentand SurveillanceScheme)

2.3.2Delivery,storageandsitehandling

TheEPSbeads:

aredeliveredtositeinlargebulkcontainerloadsorpolythenebagsandlabelledwiththeSystemname,AgrémentholdersnameandtheBDAAgrément® logoincorporatingthenumberofthisAgrément.TheEPSbeadisotherwiseunprotected; shouldbekeptdryandawayfromheatsourcesandavoidrainexposureandprotectedfromprolongedexposuretosunlight.

Damaged,contaminatedorwetmaterialsmustnotbeused.

Thebondingadhesive:

isdeliveredtositeinplasticdrums/containersandlabelledwiththeSystemname,AgrémentholdersnameandtheBDAAgrément®logoincorporatingthe numberofthisAgrément; hasanoptionalwintermixadhesiveavailablewhichhasaflowadditivetoassistincoldtemperatures; containersshouldbestoredinsideandoffthegroundatatemperaturebetween5°Cand25°Candprotectedfromfrost,directsunlightandhigh temperatures.

2.3.3Generalprocedure

InstallationoftheSystemisundertakenusinginjectionmachinesbasedonacompressedairdeliverysystem.Theinstallerprovidesallnecessaryhoses,drilling tools,equipment,injectiongunandmaterialsformakinggoodthewallsaftertheinstallation.

Wheneverpracticableandpossible,allofthecavityspacefromgroundleveltotherooforgablecopingsshouldbefilled.Installationmustbecarriedouttothe highestpointineachelevation,ortoaleveldeterminedbyanyverticalcavitybarrierbetweenadjacentproperties(whicheveristhelower)

ThetargetmeaninstalleddensityofthisSystemis12kg/m3overtheentirewall.Localareaswithinthewallmustnothaveadensityvariationofmorethan ±2kg/m3fromthetargetmeandensityoveranareaof0.5m2

ApplicationoftheSystemistobeleftuntilthecavityisweather-tight,i.e.thattheexternalmasonrywallandroofisinplaceandthatallcavityopenings,suchas thosearounddoorsandwindows,aresealed,toavoidwateringressontotheSystem.

2.3.4Preparation

Typicalpreparatoryworksinclude: repairstopointing,ifrequired; repairstothetimberframedwall,ifrequired; sleevingorotherwisemodifyingessentialventstopreventblockagebyinstallationoftheSystem; temporarysealingofwindowanddooropenings; temporarysealingofalluncappedcavitywalls; provisionofacavitytray,stopendsandweepholesatlintellevel; removalofanydebrisormortardroppingsleftinthecavity; sealingofdefectsintheopeningsintheinnerorouterleafofwallsespeciallyelectricityandgasmeterboxesusingappropriatematerial; insertionofacavitybrushatthelinedividingsemi-detachedorterracedpropertiestopermanentlycontaintheSystem

2.3.5Standardfillmethod

Masonrydrillingoperation: dependingontheinjectiongunbeingusedforapplication,22mmor26mmdiameterinjectionclearanceholesaredrilledintothemortarjointsintheouter leafatthepointwheretheverticalmortarjointmeetsthehorizontalmortarbed.

Masonrydrillingpattern:

therecommendeddrillingpatternsareillustratedinFigure1andalsogiveninwritingandasdiagramsintheSystemManualfortypicalsituationsthatcan bemetinpractice;

additionaldrillholesmayberequiredtoensurecompletefillingaroundbuildingfeatures,e.g.underwindowcills,aroundairbricks,incolumnareasbetween doorsandwindows,atthetopsofwallsandundergables.Careshouldbetakentoensurethatdrillholesdonotcoincidewithanyintermediatesuspended timberfloor.

Inordertopreventdebrisfallingontotheinsulation,alldrillingmustbecompletedononeelevationandatleast2moftheadjoiningelevationsbeforeinjection commencesonthatelevation.Eachelevationisfilledonlyaftercompletingallthedrillingrequiredinthatelevation

Timberframedrillingoperation:

core(over-drill)holesmustbe75mm

Timberframedrillingpattern:

therecommendeddrillingpatternsareillustratedinwritingandasdiagramsintheSystemManualfortypicalsituationsthatcanbemetinpractice; core(over-drill)holesmustpassonlythroughtheplasterboard;

IssueDate:July2022 ©2022KiwaLtd. Page9of14

amaximum22mmslitiscutintheVCLinthecentreofthe75mmcore(over-drill)hole; core(over-drill)holesmustbehorizontal; caremustbetakennottocausedamagetothetimberframedwall

Pre-fillingchecks

Formasonrywalls: borescopeinspectionsmustbecarriedouttoverifytheexistenceofclearcavitiesandtoidentifyanyserviceswithinthecavity.

Fortimberframedwalls:

a360°borescopecheckshouldbecarriedoutineveryvoidbeingfilledtoensurethatthetimberframedwallhasbeenbuiltinlinewiththespecification drawings;

theborescopecheckshouldbecompletedusingthedrillholestominimizethenumberofholesdrilledintheinternalplasterboard; fillingcancommenceoncetheinstallerissatisfiedthatthetimberframedwallhasbeenbuilttospecification,wiringisencasedinconduitandlocationofthe drillholeissuitable.

Checksarecarriedouttodeterminetheinjectionmachinesettingsareoptimised,including: apressureswitchtestwhichensuresthattheinjectionmachinepressureswitchisoperatingcorrectly; EPSbeadandadhesiveflowratecheckwhichensuresthattheSystemwillbeinjectedintothecavitywiththecorrectamountofadhesivebeingappliedfor thevolumeofEPSbeadsrecordedatthedesiredEPSbeaddensity.

Injectionfilling

Formasonrywalls:

TheSystemisinjectedintothecavityunderpressurethroughthedrillholesviaaflexiblepipe,fittedwithadirectionalinjectionnozzle.TheEPSbeadspacktoa uniformdensityinthecavity.TheSystemshouldbeinjectedintoeachdrillholeinturn.Fillingshouldproceedfromthebottomrowofdrillholestothetopofthe wallsandworkingacrossfromsidetosideorfromthemosttotheleastrestrictedareas,ensuringacompleteandevenfill.

SeeFigure1andtheSystemManualforfurtherdetailinrespectofthisprocedure.

Fortimberframedwalls:

injectionoftheSystemshouldbecarriedoutpriortoplasteringoftheinternalfaceofthetimberframedwall,sothatthevoidscanbeclearlyidentifiedby thevisiblelocationoffastenersinintermediatestuds.

ThevoidswithinthetimberframedwallareinjectedwiththeSystemusingadirectionalnozzletopreventdamagetotheplasterboard

SeeFigure5andtheSystemManualforfurtherdetailinrespectofthisprocedure.

2.3.6energystorethermallanceoptionmethod-masonrywalls

Theenergystorethermallanceisusedtoinstallhardtoreachareassuchasaboveconservatoriesorcarports,upto8mfromendofwalls.Theenergystore thermallancecanenabletheSystemtobeinstalledfromthecornersofpropertiesifrequired.

SeeFigures2and3,andtheSystemManualforfurtherdetailonthisprocedure.

2.3.7Partialfilloptionmethod-masonrywalls

Thepartialfillmethodisusedtotopuppre-insulatedcavitywalls.

SeeFigure4andtheSystemManualforfurtherdetailonthisprocedure.

2.3.8Finishing

Masonrywalls:

thedrillholesarefullyfilledwithmortarofasimilarcolour,textureandweathertightnesstothatoftheexistingwall.

SeetheSystemManualforfurtherdetailonthisprocedure.

Timberframedwalls:

theVCLisrepairedandtheoriginalcoreisreplacedusingadrywallrepairclip.Thecoreisthencoveredwithadhesivescrimpriortoplastering.

SeetheSystemManualforfurtherdetailonthisprocedure.

2.3.9Post-installationchecks

Post-installationexternalandinternalchecksarecarriedouttoensure:

thattheinstallationhasbeencompletedandthatnodamagehasoccurredtothebuilding; allareashavebeeninsulated;

alltheexternaldrillholeshavebeensealedwithmortarorrender;checkallinternaldrillholesintimberframedwallsarefinishedaspersection2.3.8; allareasincludingtrunkedairvents,e.g.thoseprovidingunder-floorventilationandcombustionairforheatingappliances,arecheckedandany obstructionsorEPSbeadingressmustbeclearedandthecavitybreachsealedifpossible; allfluesandchimneysmustbecarefullycheckedbyanappropriatetest(e.g.asmoketest)toverifythattheyareclearandunobstructed; EPSbeadsinjectedthroughthetopofthecavityintotheloftspaceareremovedandanypointsofleakagesealed; eavesintheloftareleftfreefromEPSbeadstofacilitateairflow; allelectriccircuitsandapplianceshavebeenreinstated.

IssueDate:July2022 ©2022KiwaLtd. Page10of14

2.4-INDEPENDENTLYASSESSEDSYSTEMCHARACTERISTICS

2.4.1AdequacyoffillofinjectedCWI(usingspecifiedinstallationmachineryanddrillingpattern) ThefillingofcavitywallswiththeSystemhasbeenwitnessedin-situduringsitevisits,including: theuseoftheenergystorethermallancetofillacavityofagablewall; thecorrectdrillingpatternandaccuracy; therecommendeddistancesbetweendrillholesanddistanceabovejoistlevel; correctinjectiontechniquebeingused

Thefillinghasalsobeenexaminedinatestrig,showingacavitycanbesufficientlyfullyfilledwiththeSystem.Afterinstalling,novoidswerevisibleinthecavity.

2.4.2Beadsizeanddensity

2.4.5Waterabsorption

Short-termwaterabsorption(24hr)bypartialimmersiontoBSEN1609,methodA,40mmthickness, 23°C,50%rh

2.4.6Behaviourinrelationtofire

Firebehaviourofaloadbearingtimberstudwall,whileunderload(5.5kNperstud)

Fireresistanceclassificationofabovewallmake-uptoBSEN13501-2

^ Testedwallconstruction12mmthickOSBboard,membrane,timberstudsandnoggins(140x39mm),superbeadinjectedbondedbeadcavitywall insulation,membrane,12.5mmthickplasterboard

2.5-ANCILLARYITEMS

AncillaryitemsdetailedinthissectionmaybeusedinconjunctionwiththeSystembutfalloutsidethescopeofthisAgrément: finishingmortarorrender; timberframedwallfinishingmaterials.

IssueDate:July2022 ©2022KiwaLtd. Page11of14
Test Result Beadsizediameterbypassingsamplesthroughagradedseriesofsieves 2to8mm InstalledtargetmeanapparentdensitytoBSEN16809-2andBSEN1602 12±2kg/m3overtheentireinstallation
Test Result TheinstalledSystemhasdeclaredthermalconductivity(90/90)toBSENISO10456andBSEN12667 0.033W/mK
Test Result Loose-fillEPSbeadshaveawatervapourresistancefactorµtoBSEN12524 2
2.4.3Thermalinsulationproperties
2.4.4Watervapourtransmission
Test Result
WS(valuedoesnotexceed1.0kg/m2)
Test Result
EuroclassE
ReactiontofireclassificationtoBSEN13501-1
Test Result
REI30^

CHAPTER3-CDM,NATIONALBUILDINGREGULATIONSANDTHIRD-PARTYACCEPTANCE

3.1-THECONSTRUCTION(DESIGNANDMANAGEMENT)REGULATIONS2015ANDTHECONSTRUCTION(DESIGNAND MANAGEMENT)REGULATIONS(NORTHERNIRELAND)2016

InformationinthisAgrémentmayassisttheclient,PrincipalDesigner/CDMco-ordinator,designerandcontractorstoaddresstheirobligationsunderthese Regulations.

3.2-NATIONALBUILDINGREGULATIONS

IntheopinionofKiwaLtd.,theSystem,ifinstalledandusedinaccordancewithChapter2ofthisAgrément,cansatisfyorcontributetosatisfyingtherelevant requirementsofthefollowingnationalBuildingRegulations.

3.2.1-ENGLAND REQUIREMENTS:THEBUILDINGREGULATIONS2010ANDSUBSEQUENTAMENDMENTS

B3(1)Internalfirespread(structure)-theSystemdoesnotprejudicethestabilityofwalls

B3(4)Internalfirespread(structure)-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

C2(a)Resistancetogroundmoisture-theSystemdoesnotabsorbwaterbycapillaryactionandmaythereforebeusedinsituationswhereitbridgesthe dampproofcourse(DPC)oftheinnerandouterleaf

C2(b)Resistancetoprecipitationmoisture-awallincorporatingtheSystemcanresistrainpenetrationtotheinnerleafandsatisfythisRequirement

C2(c)Resistancetocondensationmoisture-theSystemcancontributetosatisfyingthisRequirement

J4Protectionofbuilding-theSystemcanbeseparatedfromheatproducingappliances,fluepipes,chimneysandfireplacestopreventabuildingfrom catchingfire

L1(a)(i)Conservationoffuelandpower-theSystemcancontributetolimitingheatgainsandlossesthroughawall

Regulation7(1)-Materialsandworkmanship-theSystemismanufacturedfromsuitablysafeanddurablematerialsforitsapplicationandcanbeinstalled togiveasatisfactoryperformance

Regulation23-Requirementsrelatingtothermalelements-useoftheSystemcancontributetotheconservationoffuelandpowerinbuildingsbylimiting heatgainsandlossesthroughthermalelementsandotherpartsofthebuildingfabric

Regulation26-CO2emissionratesfornewbuildings-theSystemcancontributetosatisfyingthisRequirement

Regulation26A-Fabricenergyefficiencyratesfornewdwellings-theSystemcancontributetosatisfyingthisRequirement

Regulation26CTargetprimaryenergyratesfornewbuildings-theSystemcancontributetosatisfyingthisRequirement

3.2.2-WALES REQUIREMENTS:THEBUILDINGREGULATIONS2010ANDSUBSEQUENTAMENDMENTS

B3(1)Internalfirespread(structure)-theSystemdoesnotprejudicethestabilityofwalls

B3(4)Internalfirespread(structure)-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

C2(a)Resistancetogroundmoisture-theSystemdoesnotabsorbwaterbycapillaryactionandmaythereforebeusedinsituationswhereitbridgesthe dampproofcourse(DPC)oftheinnerandouterleaf

C2(b)Resistancetoprecipitationmoisture-awallincorporatingtheSystemcanresistrainpenetrationtotheinnerleafandsatisfythisRequirement.

C2(c)Resistancetocondensationmoisture-theSystemcancontributetosatisfyingthisRequirement

J4Protectionofbuilding-theSystemcanbeseparatedfromheatproducingappliances,fluepipes,chimneysandfireplacestopreventabuildingfrom catchingfire

L1(a)(i)Conservationoffuelandpower-theSystemcancontributetolimitingheatgainsandlossesthroughawall

Regulation7(1)Materialsandworkmanship-theSystemismanufacturedfromsuitablysafeanddurablematerialsforitsapplicationandcanbeinstalledto giveasatisfactoryperformance

Regulation23-Requirementsrelatingtothermalelements-useoftheSystemcancontributetotheconservationoffuelandpowerinbuildingsbylimiting heatgainsandlossesthroughthermalelementsandotherpartsofthebuildingfabric

Regulation26-CO2emissionratesfornewbuildings-theSystemcancontributetosatisfyingthisRequirement

Regulation26A-Primaryenergyratesfornewbuildings-theSystemcancontributetosatisfyingthisRegulation

Regulation26B-Fabricperformancevaluesfornewdwellings-theSystemcancontributetosatisfyingthisRequirement

Regulation26CMinimumenergyefficiencyrating-theSystemcancontributetosatisfyingthisRequirement

3.2.3-SCOTLAND

3.2.3.1Regulation8(1)(2)Fitnessanddurabilityofmaterialsandworkmanship

TheSystemismanufacturedfromacceptablematerialsandisconsideredtobeadequatelyresistanttodeteriorationandwearundernormalservice conditions,provideditisinstalledinaccordancewiththerequirementsofthisAgrément

3.2.3.2Regulation9BuildingStandards-Construction

2.1Compartmentation-awallincorporatingtheSystemcaninhibitthespreadoffireandsmoke

2.3Structuralprotection-theSystemdoesnotprejudicetheload-bearingcapacityofwalls

2.4Cavities-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

3.4Moisturefromtheground-theSystemcancontributetoaconstructionsatisfyingthisstandardwithreferencetoclause3.4.1oftheTechnical Handbooks;theSystemcanbeusedinsituationswhereitbridgestheDPCoftheinnerandouterleaf

IssueDate:July2022 ©2022KiwaLtd. Page12of14
REQUIREMENTS:THEBUILDING(SCOTLAND)REGULATIONS2004ANDSUBSEQUENTAMENDMENTS

3.10Precipitation-theexternalleafofacavitywallpreventsprecipitationfromreachingtheinnerleafofthewallbyallowingwatertodraindownthe resultantcavity;theSystemdoesnotinhibitthisaction

3.15Condensation-awallincorporatingtheSystemcanbedesignedandconstructedtoinhibitcondensation

3.19Combustionappliances-theSystemcanbeseparatedfromheatproducingappliances,fluepipes,chimneysandfireplacestopreventabuildingfrom catchingfire

6.1(b)Carbondioxideemissions-awallincorporatingtheSystemiscapableofreducingthecarbondioxideemissions

6.2Buildinginsulationenvelope-awallincorporatingtheSystemcanreduceheatloss

7.1(a)(b)Statementofsustainability-theSystemismanufacturedfrommaterialsthatcancontributetosatisfyingtherelevantrequirementsof Regulation9,Standards1to6,andthereforewillcontributetoaconstructionmeetingabronzelevelofsustainabilityasdefinedinthisStandard;in addition,theSystemcancontributetoaconstructionmeetingahigherlevelofsustainabilityasdefinedinthisStandard

3.2.3.3Regulation12BuildingStandards-Conversion

AllcommentsgivenunderRegulation9alsoapplytothisregulation,withreferencetoSchedule6ofTheBuilding(Scotland)Regulations2004and subsequentamendments,clause0.12oftheTechnicalHandbook(Domestic)andclause0.12oftheTechnicalhandbook(Non-Domestic)

3.2.4-NORTHERNIRELAND

REQUIREMENTS:THEBUILDINGREGULATIONS(NORTHERNIRELAND)2012ANDSUBSEQUENTAMENDMENTS

23(1)(a)(i)(iii)(b)Fitnessofmaterialsandworkmanship-theSystemismanufacturedfrommaterialswhichareconsideredtobesuitablysafeand acceptableforuseasdescribedinthisAgrément

28(a)Resistancetogroundmoisture-theSystemcancontributetosatisfyingthisRegulation

28(b)Resistancetotheweather-awallprotectstheSystemfromprecipitationtotheinnerface

29Condensation-awallshallbedesignedandconstructedtopreventinterstitialcondensation

35(1)Internalfirespread-Structure-theSystemdoesnotprejudicethestabilityofwalls

35(4)Internalfirespread-Structure-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

39(a)(i)Conservationmeasures-theSystemcancontributetolimitingheatgainsandlossesthroughawall

40(2)Targetcarbondioxideemissionrate-awallincorporatingtheSystemshallbedesignedandconstructedasnottoexceeditstargetCO2emissionrate 43Renovationofthermalelements-therenovationworkcarriedouttoensurethewallcomplieswithrequirement39(a)(i)

73(1)Protectionofpeopleandbuildings-theSystemcanbeseparatedfromheatproducingappliances,fluepipes,chimneysandfireplacestopreventa buildingfromcatchingfire

3.2.5-IRELAND REQUIREMENTS:BUILDINGREGULATIONS1997ANDSUBSEQUENTAMENDMENTS

InordertodemonstratecompliancewithIrishBuildingRegulations,thisBDAAgrément®certifiesthattheSystemcomplieswiththerequirementsofa recogniseddocumentandindicatesitissuitableforitsintendedpurposeanduse.

B3(1)Internalfirespread(structure)-theSystemdoesnotprejudicethestabilityofwalls

B3(3)Internalfirespread(structure)-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

B8(1)Internalfirespread(structure)-theSystemdoesnotprejudicethestabilityofwalls

B8(3)Internalfirespread(structure)-awallincorporatingtheSystemcaninhibittheunseenspreadoffireandsmokewithinconcealedspaces

C4Resistancetoweatherandgroundmoisture-awallcanpreventthepassageofmoisturetotheinsideofthebuilding

D1Materialsandworkmanship-theSystemismanufacturedfromacceptablematerialsandisconsideredtobeadequatelyresistanttodeterioration andwearundernormalserviceconditions,provideditisinstalledinaccordancewiththerequirementsofthisAgrément

J3Protectionofbuilding-theSystemcanbeseparatedfromheatproducingappliances,fluepipes,chimneysandfireplacestopreventabuildingfrom catchingfire

L1Conservationoffuelandenergy-theSystemcancontributetolimitingheatgainsandlossesthroughwallsandconservefuelandenergy

L2(a)Conservationoffuelandenergy(inexistingdwellings)-theSystemcancontributetolimitingheatgainsandlossesthroughwalls

L4(a)Conservationoffuelandenergy(inexistingbuildingsotherthandwellings)-theSystemcancontributetolimitingheatgainsandlossesthroughwalls

L5(c)Conservationoffuelandenergy(innewbuildingsotherthandwellings)-theSystemcancontributetolimitingheatgainsandlossesthroughwalls

Regulation7Conservationoffuelandenergyinexistingdwellings-theSystemcancontributetosatisfyingthisRequirement

Regulation8(c)Conservationoffuelandenergyinnewdwellings-theSystemcancontributetosatisfyingthisRequirement

33-THIRD-PARTYACCEPTANCE

NHBC-IntheopinionofKiwaLtd.,theSystem,ifinstalledinareasotherthanverysevereexposurezonelocationswithfair-facedmasonry,andusedand maintainedinaccordancewiththisAgrément,cansatisfyorcontributetosatisfyingtherelevantrequirementsinrelationtoNHBCStandards,Chapter6.1 ExternalmasonrywallsandChapter6.2Externaltimberframedwalls.

REDcert-TheSystemisindependentlyauditedandcertifiedbyREDcerttotheREDcert2schemetoensurethemanufacturingprocessusesverifiedbiofuels thatleadto80%lessCO2ethanthegreyEPSbeadproducedusingconventionalfuels.

Page13of14
IssueDate:July2022 ©2022KiwaLtd.

CHAPTER4-SOURCES

BSENISO6946:2017Buildingcomponentsandbuildingelements.Thermalresistanceandthermaltransmittance.Calculationmethods

BSENISO10211:2017Thermalbridgesinbuildingconstruction.Heatflowsandsurfacetemperatures.Detailedcalculations

BSENISO10456:2007Buildingmaterialsandproducts.Hygrothermalproperties.Tabulateddesignvaluesandproceduresfordeterminingdeclaredand designthermalvalues

BSENISO11925-2:2010Reactiontofiretests.Ignitabilityofproductssubjectedtodirectimpingementofflame.Single-flamesourcetest

BSENISO13788:2012Hygrothermalperformanceofbuildingcomponentsandbuildingelements.Internalsurfacetemperaturetoavoidcriticalsurface humidityandinterstitialcondensation.Calculationmethods

BSEN1363-1:2020Fireresistancetests.Generalrequirements

BSEN1363-2:1999Fireresistancetests.Alternativeandadditionalprocedures

BSEN1365-1:2012Fireresistancetestsforloadbearingelements.Walls

BSEN1602:2013Thermalinsulatingproductsforbuildingapplications.Determinationoftheapparentdensity

BSEN1609:2013Thermalinsulatingproductsforbuildingapplications.Determinationofshorttermwaterabsorptionbypartialimmersion

BSEN12524:2000Buildingmaterialsandproducts.Hygrothermalproperties.Tabulateddesignvalues

BSEN12667:2001Thermalperformanceofbuildingmaterialsandproducts.Determinationofthermalresistancebymeansofguardedhotplateandheat flowmetermethods.Productsofhighandmediumthermalresistance

BSEN13172:2012Thermalinsulationproducts.Evaluationofconformity

BSEN13238:2010Reactiontofiretestsforbuildingproducts.Conditioningproceduresandgeneralrulesforselectionofsubstrates

BSEN13501-1:2018Fireclassificationofconstructionproductsandbuildingelements-Classificationusingdatafromreactiontofiretests

BSEN13501-2:2016Fireclassificationofconstructionproductsandbuildingelements.Classificationusingdatafromfireresistancetests,excluding ventilationservices

BSEN15026:2007Hygrothermalperformanceofbuildingcomponentsandbuildingelements.Assessmentofmoisturetransferbynumericalsimulation DraftBSEN16809-1.Thermalinsulationproductsforbuildings.In-situformedproductsfromloose-fillexpandedpolystyrene(EPS)beadsandbonded expandedpolystyrenebeads.Part1.Specificationforthebondedandloosefilledproductsbeforeinstallation

BSEN16809-2:2017Thermalinsulationproductsofbuildings.In-situformedproductsfromloose-fillexpandedpolystyrene(EPS)beadsandbonded expandedpolystyrenebeads.Specificationforthebondedandloose-fillproductsafterinstallation

BS476-21:1987Firetestsonbuildingmaterialsandstructures.Methodsfordeterminationofthefireresistanceofloadbearingelementsofconstruction BS5250:2011+A1:2016Codeofpracticeforcontrolofcondensationinbuildings

BS8104:1992Codeofpracticeforassessingexposureofwallstowind-drivenrain

BREReport262:2002Thermalinsulation:avoidingrisks

BREReport443:2006ConventionsforU-valuecalculations

BREReport497:2016Conventionsforcalculatinglinearthermaltransmittanceandtemperaturefactors

BREInformationPaperIP1/06:2006Assessingtheeffectsofthermalbridgingatjunctionsandaroundopenings

BREGBG44-2:2000Insulatingmasonrycavitywalls:principalrisksandguidance

BREGG33:2015Buildingdamp-freecavitywalls

CIGATechniciansguidetobestpractice:2002Installingcavitywallinsulation

CIGACWI-Guidetobestpractice:2008WorkingatheightintheretrofitCWIindustry

CIGATechniciansguidetobestpractice:2016Flues,chimneysandcombustionairventilators

NHBCStandards2019

PAS2030:2019+A1:2022Specificationfortheinstallationofenergyefficiencymeasuresinexistingdwellings

PAS2035:2019+A1:2022Retrofittingdwellingsforimprovedenergyefficiency.Specificationandguidance

PD6697:2019RecommendationsforthedesignofmasonrystructurestoBSEN1996-1-1andBSEN1996-2

REDcert2Certificationsystemforthepurposeofmassbalancedproducts

Remark:apartfromthesesourcesconfidentialreportsmayalsohavebeenassessed;anyrelevantreportsareinthepossessionofKiwaLtdandkeptin theTechnicalAssessmentFileofthisAgrément;theInstallationGuidesarecurrentatthetimeofpublicationandmaybesubjecttochange,theAgrément holdershouldbecontactedforclarificationofrevision

CHAPTER5-AMENDMENTHISTORY

IssueDate:July2022 ©2022KiwaLtd. Page14of14
Revision AmendmentDescription AmendedBy ApprovedBy Date - Firstissue AChapman CDevine July2022 A UpdatestoBuildingRegulationsandFirePerformance ETaylor CDevine August2023
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.