1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University. Cladding wall battens to be placed over wall structural members, fit blocking where required
E
E
All panel backers to line up with wall battens
E02 A-594
1
2
3
4
5
6
7 TEAM NAME:
D05 A-598
NORTH WEST FACE
REMOVABLE CORNER COVER BOARD SEE A-598 FOR DETAIL
NORTH EAST FACE
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
A D
D
CONSULTANTS STANDARD PANEL CONNECTION
B
C
WEST FACE
WEST FACE
C
CLIENT U.S. DEPARTMENT OF ENERGY
E03
M1
A-595
M2
M4
M5
SOLAR DECATHLON 2011
E04
M6
A-595
www.solardecathlon.gov
CENTRE MODULE OMITTED FOR CLARITY
B
B
MARK ALL CONNECTIONS LOCATED OVER WALL STRUCTURAL MEMBERS
LOCKING PANEL CONNECTION
TIMBER BLOCKING WHERE REQUIRED
DATE
DESCRIPTION
D06 A-598
LOT NUMBER: BL
DRAWN BY:
C
CHECKED BY:
GM, TD
COPYRIGHT:
SOUTH WEST FACE
SOUTH EAST FACE SHEET TITLE:
A
E01
S01
A-593
A-592
CLADDING LAYOUT PLAN A
A-591 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
A
C
Panels are hung from the bottom up with each subsequent panel fitted over the one below
E
PARAPET COVERBOARD SEE A-598 FOR DETAIL
PARAPET FLASHING
PARAPET FLASHING
PARAPET COVERBOARD SEE A-598 FOR DETAIL
E
Northeast face uses the Type 2 wall channel configuration Northwest face uses the Type 1 wall channel configuration See A-596 for panel construction details
2.990 TOP OF PARAPET See A-597 for wall channel details PANEL SERIES 5
PANEL SERIES 7
PANEL P5-SE
D
TEAM NAME:
PANEL P7-SE
PANEL SERIES 4
ROOF STRUCTURE
ROOF STRUCTURE
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
D
CONSULTANTS PANEL SERIES 6 PANEL P4B-SE
PANEL P6A-NE
WALL STRUCTURE
WALL STRUCTURE
PANEL SERIES 3
PANEL SERIES 3
PANEL P3A-NE
PANEL P3B-SE C
C
CLIENT U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011 www.solardecathlon.gov
PANEL SERIES 2
PANEL SERIES 2
PANEL P2-NE
PANEL P2B-SE
B
FLOOR STRUCTURE
B
FLOOR STRUCTURE
PANEL SERIES 1
PANEL SERIES 1 0.000 F.F.L
MARK PANEL P1-SE
PANEL P1-NE
DATE
DESCRIPTION
LOT NUMBER: BL
DRAWN BY: CHECKED BY:
GM, TD
COPYRIGHT: ALUMINIUM WALL CHANNEL TYPE 1
45X35 H3.2 TIMBER CAVITY BATTEN
45X35 H3.2 TIMBER CAVITY BATTEN
ALUMINIUM WALL CHANNEL TYPE 2
-0.550 TOP OF GRADE SHEET TITLE:
PANELS SOUTH EAST FACE
PANELS NORTH EAST FACE
A
A
CLADDING ASSEMBLY SECTION
A-592 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University. Cladding panels designated by panel series number (P1-P7), letter of panels in that series from left to right (A-C) then the building face that the panel is on (NE - Northeast, NW- Northwest, SE - Southeast, SW Southwest, E - East, W - West)
E
E
Southeast & Southwest faces use the Type 1 wall channel configuration see A-597 for details
1
2
1100
1112
4
3
1100
5
1100
1100
7
6
1100
1100
1100
1100
1112 TEAM NAME:
37
342
733
733
733
733
733
266
101
101
266
733
733
733
248
733
733
733
248
733
458
733
342
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
37 2.990 TOP OF PARAPET
342
PANEL SERIES 5 D
D
P5-SW
C5
C5
C5
C5
C5
P5-SE
C5
CONSULTANTS
C5
PANEL SERIES 4
P4A-SW
P4B-SW
P4A-SE
P4C-SE
P4B-SE
PANEL SERIES 3
C1
C1
C1
P3A-SW
C1
L2
P3B-SW
L1
L1
P3A-SE
L2
C1
P3B-SE
C1
C1
C2
L2
C1
P3C-SE
C1
C1
PANEL SERIES 2
C
C
P2A-SW
CENTRE MODULE OMITTED FOR CLARITY
P2B-SW
P2A-SE
CLIENT
P2C-SE
P2B-SE
U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011 www.solardecathlon.gov
PANEL SERIES 1 0.000 F.F.L P1-SE
P1-SW
C7
C7
C7
C7
C7
C7
C7
-0.550 TOP OF GRADE
SOUTH WEST FACE
1
TYPE 1 STANDARD WALL CHANNELS SHOWN DOTTED
2
ALL PANEL BACKERS TO LINE UP WITH WALL CHANNELS
B
SOUTH EAST FACE
TYPE 1 LOCKING WALL CHANNELS SHOWN DASHED
TOP WEATHERBOARD REMOVED AT WINDOW EDGE, ALUMINIUM ANGLE REDUCED FROM 425MM TO 300MM IN THIS SECTION
3
4
BOTTOM PANELS NOTCHED AROUND FOUNDATION STRUCTURAL MEMBERS WHERE REQUIRED. EXACT SIZE AND SHAPE TO BE CONFIRMED DURING CONSTRUCTION TOP WEATHERBOARD REMOVED AT WINDOW EDGE, ALUMINIUM ANGLE REDUCED FROM 425MM TO 300MM IN THIS SECTION
5
6
P1-Sw
TOP WEATHERBOARD REMOVED AT WINDOW EDGE, ALUMINIUM ANGLE REDUCED FROM 425MM TO 300MM IN THIS SECTION
7 B
P1-SE
MARK P2A-SW
PA2-SW
P2B-SE
P2A-SE
DATE
DESCRIPTION
P2B-SE LOT NUMBER: BL
DRAWN BY: P3A-SW
PA3-SW
P3B-SE
P3A-SE
CHECKED BY:
P3B-SE
GM, TD
COPYRIGHT:
P4A-SW
PA4-SW
P4B-SE
P4A-SE
P4B-SE SHEET TITLE:
P5-SW A
INDIVIDUAL PANELS
P5-SE LOCKING PANEL BACKER
45X35 H3.2 INTERMEDIATE TIMBER PANEL BACKER
STANDARD PANEL BACKER
A
CLADDING PANEL LAYOUT ELEVATIONS
A-593 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University. Cladding panels designated by panel series number (P1-P7), letter of panels in that series from left to right (A-C) then the building face that the panel is on (NE - Northeast, NW- Northwest, SE - Southeast, SW Southwest, E - East, W - West)
E
E
Northeast face uses the Type 2 wall channel configuration see A-597 for details Northwest face uses the Type 1 wall channel configuration see A-597 for details
7
6
5
1100
1112
1100
4
1100
1100
3
2
1100
1100
1
1100
1100
1112 TEAM NAME:
37
342
733
733
733
733 294
733
733
336
733 294
733
260
107
107
259
733
733
733
733
733
342
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
37
336
2.990 TOP OF PARAPET
PANEL SERIES 7
PANEL SERIES 5
D
D
P7-NE
C10
CONSULTANTS
P5-NW
C10
PANEL SERIES 4 PANEL SERIES 6 P4-NW P6B-NE
P6A-NE
P6C-NE
PANEL SERIES 3
PANEL SERIES 3
C8
C8
P3A-NE
C8
L5
C8
C9
C8
P3B-NE
L5
C8
C9
C8
C8
P3C-NE
L4
L1
C1
C1
P3-NW
C1
C1
C1
C1
C1
PANEL SERIES 2
PANEL SERIES 2
C
C
CLIENT
CENTRE MODULE OMITTED FOR CLARITY
P2-NE
P2-NW
U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011
C4
C4
www.solardecathlon.gov
PANEL SERIES 1
PANEL SERIES 1 0.000 F.F.L P1-NE
P1-NW
-0.550 TOP OF GRADE
NORTH EAST FACE
BOTTOM PANELS NOTCHED AROUND FOUNDATION STRUCTURAL MEMBERS WHERE REQUIRED. EXACT SIZE AND SHAPE TO BE CONFIRMED DURING CONSTRUCTION
TYPE 2 STANDARD WALL CHANNELS SHOWN DOTTED
7
6
TYPE 2 LOCKING WALL CHANNELS SHOWN DASHED
NORTH WEST FACE
TYPE 1 LOCKING WALL CHANNELS SHOWN DASHED
5
4
TYPE 1 STANDARD WALL CHANNELS SHOWN DOTTED
3
2
1
B
B
P1-SW
P1-NW
MARK P4B-NE
P2A-NE
DATE
DESCRIPTION
P2-NW
P4C-NE
LOT NUMBER: BL
DRAWN BY: P3B-NE
P3A-NE
CHECKED BY:
P3-NW
P3C-NE
GM, TD
COPYRIGHT:
P4A-SW
P4-NW SHEET TITLE:
P5-SW A
INDIVIDUAL PANELS
P5-NW
ALL PANEL BACKERS TO LINE UP WITH WALL CHANNELS
STANDARD ALUMINIUM PANEL BACKER
45X35 H3.2 INTERMEDIATE TIMBER PANEL BACKER
LOCKING ALUMINIUM PANEL BACKER
A
CLADDING PANEL LAYOUT ELEVATIONS
A-594 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
A
E
B
C
Cladding panels designated by panel series number (P1-P7), letter of panels in that series from left to right (A-C) then the building face that the panel is on (NE - Northeast, NW- Northwest, SE - Southeast, SW Southwest, E - East, W - West)
E
East & West faces use the Type 1 wall channel configuration see A-597 for details 78
796
601
600
553
670
670
670
679
37 2.990 TOP OF PARAPET
PANEL SERIES 5
C3
B
C
P5-W C3
A TEAM NAME:
C3
PANEL SERIES 4
78
P4-W
705
781
781
781
781
781
627
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
37 2.990 TOP OF PARAPET
D
D
PANEL SERIES 5
CONSULTANTS
PANEL SERIES 3 C5 C1
C1
C1
C1
C1 L3
P3A-W
P5-E
C5
C5
C5
L1 P3B-W PANEL SERIES 4
PANEL SERIES 2 P4B-E
P4A-E
P4C-E
P2-W PANEL SERIES 3 C4
C4
C4
PANEL SERIES 1 0.000 F.F.L
L1
C1
L2
C1
P3A-E
P3B-E
C2
L2
C1 P3C-E
P1-W C
C
PANEL SERIES 2
CLIENT
-0.550 TOP OF GRADE
U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011
WEST FACE
P2B-E
P2A-E
TYPE 1 LOCKING WALL CHANNELS SHOWN DASHED
TYPE 1 STANDARD WALL CHANNELS SHOWN DOTTED
www.solardecathlon.gov
P2C-E
PANEL SERIES 1
A
LOCKING PANEL BACKER
ALL ALUMINIUM PANEL BACKERS TO LINE UP WITH WALL CHANNELS
B
0.000 F.F.L
C C7
C6
P1-E
C7
C7
P5-W
-0.550 TOP OF GRADE
EAST FACE
P4-W
TYPE 1 LOCKING WALL CHANNELS SHOWN DASHED
TYPE 1 STANDARD WALL CHANNELS SHOWN DOTTED
B
B
P3A-W
C
P3B-W
ALL ALUMINIUM PANEL BACKERS TO LINE UP WITH WALL CHANNELS
TOP WEATHERBOARD REMOVED AT WINDOW EDGE, ALUMINIUM ANGLE REDUCED FROM 425MM TO 300MM IN THIS SECTION
P2-W
B
A
TOP WEATHERBOARD REMOVED AT WINDOW EDGE, ALUMINIUM ANGLE REDUCED FROM 425MM TO 300MM IN THIS SECTION
MARK
P1-E
DATE
DESCRIPTION
LOT NUMBER: P1-W
INDIVIDUAL PANELS
P2A-E
P2B-E
BL
DRAWN BY:
P2C-E
CHECKED BY:
45X35 H3.2 INTERMEDIATE TIMBER PANEL BACKER
GM, TD
COPYRIGHT: LOCKING PANEL BACKER
P3A-E
P3B-E
P3C-E
SHEET TITLE: P4A-E
P4B-E
P4C-E
A
A
P5-E
INDIVIDUAL PANELS
CLADDING PANEL LAYOUT ELEVATIONS
45X35 H3.2 INTERMEDIATE TIMBER PANEL BACKER
A-595 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES TOP OF PANEL BACKER TO BE TRIMMED ONSITE DURING PANEL CONSTRUCTION
425MM ALUMINIUM PANEL BACKER
700MM ALUMINIUM PANEL BACKER
700MM ALUMINIUM PANEL BACKER
700MM ALUMINIUM PANEL BACKER
550MM ALUMINIUM PANEL BACKER
550MM ALUMINIUM PANEL BACKER
Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
700MM ALUMINIUM PANEL BACKER
Panels shown with standard panel backer, for locking connections replace relevant angle with equivalent locking panel backer
E
B
B
C
B
C
B
E
There are four different lengths of standard and locking panel backer: - 700mm, 550mm, 425mm, 300mm Each length has a standard cut pattern at top and bottom. See A-598 for details
B
45x35 Full height H3.2 timber panel batten shown dotted
A
Single stainless steel screw fixing into each weatherboard
A
5mm spacing between Aluminium Angle backer and edge of bottom weatherboard
10
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
2 TEAM NAME: 3 50
C
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
25
469 Full height
C
300 Part height
B
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
B
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
A
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
30
25
D
CONSULTANTS
10
B
10
B
D
B
LOCKING PANEL BACKER (UA 3226)
10
OUTLINE OF 300MM ALUMINIUM ANGLE BACKER SHOWN DOTTED
FIRSTLIGHT NZ
PANEL BACKER ANGLE (UA 1103)
ALUMINIUM PANEL BACKERS
B
B WEATHERBOARD TYPE A
629
-HERMAN PACIFIC CP837
90
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
5
27
A
10
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
5
STAINLESS STEEL SCREWS 10MM FROM BOTTOM EDGE OF WEATHERBOARD
C
C
B
10
C
B
588
19
C
C
CLIENT
B
C
U.S. DEPARTMENT OF ENERGY 19
A
SOLAR DECATHLON 2011
729
B
P1-SW P1-SE P1-W P1-NE P1-NW P1-E
www.solardecathlon.gov 748
B
WEATHERBOARD TYPE B -HERMAN PACIFIC CP835
798
788
A B
A 5
A
140
5
PANEL SERIES 1
C
PANEL SERIES 6
B
P6A-NE P6B-NE P6C-NE
27
C
PANEL SERIES 5
B
P4-SW P4A-SE P4B-SE P4-W P4-NW P4A-E P4B-E P4C-E
5
C
B
5
A
19
C LOT NUMBER:
1
5
P3A-SW P3B-SW P3A-SE P3B-SE P3C-SE P3A-W P3B-W P3A-NE P3B-NE P3C-NE P3-NW P3A-E P3B-E P3C-E
CHECKED BY:
PANEL SERIES 4 P4A-SW P4B-SW P4A-SE P4B-SE P4C-SE P4-W P4-NW P4A-E P4B-E P4C-E
3
GM, TD
COPYRIGHT:
PANEL SERIES 7
SHEET TITLE:
P7-NE
A
WEATHERBOARD PROFILES
2
BL
DRAWN BY:
27
A
DESCRIPTION
190
5 P2A-SW P2B-SW P2A-SE P2B-SE P2C-SE P2-W P2-NE P2-NW P2A-E P2B-E P2C-E
DATE
HERMAN PACIFIC - CP836
PANEL SERIES 3
PANEL SERIES 2
MARK
WEATHERBOARD TYPE C
4
5
6
7
CLADDING PANEL DETAILS
A-596
1
2
3
5
4
5
6
7
GENERAL NOTES
5
2
ALUMINIUM ROD (UA 1270) GLUE FIXED TO ALUMINIUM CHANNELS AT INDICATED CENTRES
ALUMINIUM ROD Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University. 50
20
30
14
10
ALUMINIUM ROD (UA 1270) GLUE FIXED TO ALUMINIUM CHANNELS AT INDICATED CENTRES
3
There are two configurations of wall channels; type 1 and type 2. Channels C1 and C8 are the full height versions of the two types. Each subsequent channel is a section of these full height channels.
36
E
E
ALUMINIUM CHANNEL 25 STANDARD WALL CHANNEL (UA 1141)
25 ISOMETRIC EXAMPLE LOCKING WALL CHANNEL (UA 3227)
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
89
88 89
88 89
80
88
88
465
D
615
615
751
CONSULTANTS
46
93
93
PANEL SERIES 6
46
C5
46
51
103
615
465 51
103 1304
51
103
PANEL SERIES 4
TEAM NAME:
CLADDING PANELS SEE A-596 FOR DETAILS
596
D
PANEL SERIES 7
80
88 80 465
545
80
PANEL SERIES 5
88
88
2.990 TOP OF PARAPET
465
465
465
465
82
82
82
82
PANEL SERIES 3
C
249
615
615
3190 2151
77
154
77
PANEL SERIES 2 154
76
153
153
www.solardecathlon.gov
615
366
733
615
3190
249 366
2186 366
2306 1598
76
153
PANEL SERIES 2 153
U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011
3190 615
2186
615
3190
249
C3
CLIENT
1286
1286
42
C
83
83
83
PANEL SERIES 3
83
42
615
615
615
615
615
C10
C9
L3
L5
CLADDING PANELS SEE A-596 FOR DETAILS
865
615 865
615
1153
865
615
615
615
615
B
615
B
LOT NUMBER:
108
108 50 66
L2
50 66
54
50 66
DESCRIPTION
BL
CHECKED BY:
GM, TD
COPYRIGHT: 215
215
215
215
288
215
215
215
ALUMINIUM ROD (UA 1270) GLUE FIXED TO ALUMINIUM CHANNELS AT INDICATED CENTRES
DATE
DRAWN BY:
120
108
PANEL SERIES 1
408
C2
50
50 66
50 66 54
108
54
50 66
0.000 F.F.L
120
108
PANEL SERIES 1
MARK
C1
C4
C6
C7
L1
23
23
23
23
23
23
23
SHEET TITLE:
C8
L4
A
A
-0.550 TOP OF GRADE
TYPE 1 STANDARD CHANNELS
TYPE 1 LOCKING CHANNELS
- SOUTHWEST FACE - SOUTHEAST FACE - NORTHWEST FACE - WEST FACE - EAST FACE
1
TYPE 2 STANDARD CHANNELS
- SOUTHWEST FACE - SOUTHEAST FACE - NORTHWEST FACE - WEST FACE - EAST FACE
2
3
4
CLADDING WALL CHANNELS
TYPE 2 LOCKING CHANNELS
- NORTHEAST FACE
- NORTHEAST FACE
A-597 5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
TIMBER WEATHERBOARD PANEL
The locking connection prevents lateral movement of the wall panel and provides an accurate locator for assembly.
E
50
The standard connection allows for thermal expansion and contraction of the weatherboard panel Parapet coverboard screw fixed to parapet to prevent cladding panel uplift
61
25
MINIMUM CAVITY DEPTH OF 61MM TO ALLOW FOR INTERNAL GUTTER SYSTEM
LOCKING PANEL BACKER UA 3226 FIXED TO WEATHERBOARDS WITH 19MM STAINLESS STEEL SCREWS, SEE A-597 FOR FURTHER DETAILS
E
Corner coverboard screw fixed in place after cladding panels hung FULL HEIGHT DPC STRIP STAPLED BETWEEN PLYWOOD AND ALUMINIUM CHANNEL
TEAM NAME:
50
50
50MM STAINLESS STEEL 6 GAUGE PAN HEAD SCREW WITH 12MM STAINLESS STEEL WASHER FIXED @ 400CRS MAX
9
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
72
68
28
R4 12MM PLYWOOD OUTER LAYER
9
R4
LOCKING WALL CHANNEL UA 3227 WITH ALUMINIUM SOLID ROD UA 1270 INSERTED THROUGH FLANGES AND GLUE FIXED, SEE A-597 FOR REQUIRED CENTRES
35
D
4 6
10
ROUGH SAWN CEDAR COVER BOARD WITH 9MM CEDAR SPACER FIXED TO BACK EDGE
87
31
31
4
CONSULTANTS
ALL CHANNELS FIXED TO WALL STRUCTURE, FIT BLOCKING WHERE REQUIRED
26
35
D
14
C
C
CLIENT U.S. DEPARTMENT OF ENERGY TIMBER WEATHERBOARD PANEL
SOLAR DECATHLON 2011 www.solardecathlon.gov
STANDARD WALL CHANNEL UA 1141 WITH ALUMINIUM SOLID ROD UA 1270 INSERTED THROUGH FLANGES AND GLUE FIXED, SEE A-597 FOR REQUIRED CENTRES
26MM STAINLESS STEEL 6 GAUGE PAN HEAD SCREW WITH 12MM STAINLESS STEEL WASHER FIXED @ 400CRS MAX
FULL HEIGHT DPC STRIP STAPLED BETWEEN TIMBER BATTEN AND ALUMINIUM CHANNEL
19
4
10
12
B
17
4 6
35
35
R4
R4
B
STANDARD PANEL BACKER UA 1103 FIXED TO WEATHERBOARDS WITH 19MM STAINLESS STEEL SCREWS, SEE A-596 FOR FURTHER DETAILS
69MM WIDE ROUGH SAWN CEDAR COVERBOARD SCREW FIXED TO TIMBER BATTEN
32
11
25X35 H3.2 TIMBER BATTEN FIXED TO WALL STRUCTURE
MARK
20
DATE
DESCRIPTION
12MM PLYWOOD OUTER LAYER LOCKING PANEL BACKER ALUMINIUM CHANNEL (UA 3226)
ISOMETRIC EXAMPLE
30X20MM CEDAR TIMBER BATTEN
69
ISOMETRIC EXAMPLE
LOT NUMBER: BL
DRAWN BY:
ALL CHANNELS FIXED TO WALL STRUCTURE, FIT BLOCKING WHERE REQUIRED
CHECKED BY:
GM, TD
COPYRIGHT:
19
28
90MM WIDE ROUGH SAWN CEDAR COVERBOARD SCREW FIXED TO TIMBER BATTEN
29
STANDARD PANEL BACKER ALUMINIUM ANGLE (UA 1103)
STAINLESS STEEL SCREWS @ 400 CRS. FIXED 28MM FROM OUTSIDE CORNER TO MAINTAIN A VERTICAL FIXING LINE
A
SHEET TITLE:
28 90
A
CLADDING COMPONENT DETAILS
A-598 1
2
3
4
5
6
7
1
2
3
4
5
6
7
GENERAL NOTES Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
30000
ACCESS ROAD
ACCESS ROAD
ACCESS ROAD ALTERNATE CRANE LOCATION
E
E
22000 8000
TRUCK 1
MODULE 1
MODULE 2
TRUCK 2 CRANE
TEAM NAME:
20' CONTAINER
20' CONTAINER
CRANE
20' CONTAINER
20' CONTAINER
M1
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
M2
D
D
CONSULTANTS
20' CONTAINER DELIVERED TO SITE SITE SETUP SITE SURVEY FOUNDATION PADS LAID
FOUNDATION STRUCTURE ASSEMBLED AND CHECKED CRANE SETUP
DECATHLETE WAY
MODULE 1 CRANED INTO PLACE AND FIXED TO FOUNDATION STRUCTURE MODULE 2 CRANED INTO PLACE\HAND WINCHED INTO MODULE 1 AND SECURED
DECATHLETE WAY
DECATHLETE WAY
N C
C
CLIENT U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011 www.solardecathlon.gov ACCESS ROAD
MODULE 3
ACCESS ROAD
MODULE 4
TRUCK 3
MODULE 5
ACCESS ROAD
MODULE 6
TRUCK 4
40' CONTAINER
CRANE
TRUCK 5
CRANE
CRANE 40' CONTAINER
M1
M2
M3
M4
PV PANELS & SUBSTRUCTURE
20' CONTAINER
20' CONTAINER
B
20' CONTAINER
B
M1
M2
M3
M4
M5
CANOPY COMPONENTS
MARK
M6
M1
M2
M3
M4
M5
DATE
DESCRIPTION
LOT NUMBER:
M6
DRAWN BY:
BL
CHECKED BY:
GM, TD
CLADDING
COPYRIGHT:
DECKING SHEET TITLE:
MODULE 3 CRANED INTO PLACE\HAND WINCHED INTO MODULE 2 AND SECURED MODULE 4 CRANED INTO PLACE\HAND WINCHED INTO MODULE 3 AND SECURED
A
MODULE 5 CRANED INTO PLACE\HAND WINCHED INTO MODULE 4 AND SECURED MODULE 6 CRANED INTO PLACE\HAND WINCHED INTO MODULE 5 AND SECURED MODULE JOINS WEATHERPROOFED
DECATHLETE WAY
ASSEMBLY SEQUENCE
40' CONTAINER ARRIVES ONSITE AND CONTENTS UNLOADED TO DESIGNATED AREAS 40' CONTAINER LEAVES SITE INTER-MODULE CONNECTIONS MADE
DECATHLETE WAY
A
DECATHLETE WAY
O-101 1
2
3
4
5
6
7
1
2
3
4
6
5
7
GENERAL NOTES
ACCESS ROAD
ACCESS ROAD
Do not scale of drawings. All dimensions to be checked onsite. All drawings to be read in conjunction with relevant specifications and supplementary documents. The work executed from, and all information contained within the drawings, specifications and other documents falls under copyright law, and remains the property of Victoria University.
ACCESS ROAD
E
E
8000
20' CONTAINER
M1
CANOPY COMPONENTS
M2
M3
M5
M4
M6
PV PANELS & SUBSTRUCTURE
M1
M2
20' CONTAINER
PV PANELS & SUBSTRUCTURE
20' CONTAINER
20' CONTAINER
CRANE
TRUCK 1
M3
M4
M5
TEAM NAME:
M6
M1
M2
M3
M5
M4
FIRSTLIGHT NZ
ADDRESS:
139 VIVIAN STREET TE ARO, WELLINGTON NEW ZEALAND
CONTACT:
www.firstlighthouse.ac.nz info@firstlighthouse.ac.nz
M6
D
D
CLADDING
CONSULTANTS
DECKING
DECKING
EXTERIOR CLADDING INSTALLED CANOPY STRUCTURE PART ASSEMBLED ON GROUND AND CRANED INTO PLACE
PV SUBSTRUCTURE AND PANELS INSTALLED ON CANOPY CRANE LEAVES SITE DECKING FOUNDATION PADS LAID
DECATHLETE WAY
DECKING AND LANDSCAPING INSTALLED SITE CLEANUP 20' CONTAINER LEAVES SITE
DECATHLETE WAY
DECATHLETE WAY
N C
C
CLIENT U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011 www.solardecathlon.gov
CONSTRUCTION EQUIPMENT 40' CONTAINER
MODULE 5
EQUIPMENT TYPE
AMOUNT
NOTES
PPE - SAFETY BOOTS, SAFETY GLASSES, EAR MUFFS, HARD HATS,GLOVES, HIGH VIABILITY VESTS, SAFETY HARNESSES
1 UNIT PER PERSON + SPARES INCASE OF DAMAGE (EXCEPT HARNESSES)
EXACT HARNESS QUANTITIES TO BE CONFIRMED
SITE EQUIPMENT - LIGHTING, SAFETY SIGNAGE, SAFETY BARRIERS, SHELTER
AS REQUIRED
EXACT TYPES AND QUANTITIES TO BE CONFIRMED
TOOLS - POWER TOOLS, HAND TOOLS
AS REQUIRED
EXACT TYPES AND QUANTITIES TO BE CONFIRMED
ELECTRICAL GENERATOR AND SPILL TRAYS
MINIMUM 2 GENERATORS AND ASSOCIATED SPILL TRAYS
EXACT SIZE AND TYPE OF GENERATORS TO BE CONFIRMED
TRUCK WITH MOUNTED CRANE FOR 20' CONTAINER (TRUCK 1)
1
TRUCK MUST HAVE ADEQUATE HIAB SYSTEM TO ENABLE CONTAINER PLACEMENT
SIDE LOADER TRUCK FOR 40' CONTAINER (TRUCK 5)
1
THE USE OF THE SIDE LOADER TRUCK OR ONSITE CRANE TO LIFT THE 40' CONTAINER INTO PLACE IS UNDER INVESTIGATION
SEMI TRAILER FLATBED TRUCKS (TRUCKS 2, 3 & 4)
3
EXACT MODEL\SIZE OF TRUCK AND TRAILER TO BE CONFIRMED, EACH TRUCK MUST BE ABLE TO CARRY 2 MODULES
MOBILE SITE CRANE - MINIMUM 80 METRIC TONNE (CRANE LOCATION 1) MINIMUM 100 METRIC TONNE (ALTERNATE CRANE LOCATION)
1
EXACT CRANE SIZE TO BE CONFIRMED. CRANE SIZE WILL ALTER DEPENDING ON MODULE/CONTAINER WEIGHT AND CRANE PLACEMENT
20 FOOT CONTAINER
1
THIS CONTAINER WILL BE THE FIRST PIECE OF EQUIPMENT ONSITE AND WILL CARRY PPE, SITE EQUIPMENT, TOOLS AND FOUNDATIONS
1
THIS CONTAINER WILL HOUSE CLADDING & CANOPY SYSTEMS, PV SYSTEMS, DECK & LANDSCAPING SYSTEM, VARIOUS OTHER EQUIPMENT
TRUCK 5
MODULE 6
TRUCK 4
B
B
MODULE 3
MODULE 4
TRUCK 3
MARK
DATE
DESCRIPTION
LOT NUMBER: BL
DRAWN BY: CHECKED BY:
GM, TD
COPYRIGHT:
MODULE 1
MODULE 2
40 FOOT CONTAINER
TRUCK 2
SHEET TITLE:
A
A
20' CONTAINER
TRUCK 1
ASSEMBLY SEQUENCE & SCHEDULES
O-102 1
2
3
4
5
6
7