C
Suffix
HC
BEVEL
000
HC-BEVEL-000 Drawing Index
20/12/11
HC
BEVEL
100
HC-BEVEL-100 Bevel Back Weatherboard System Profiles
20/12/11
HC
BEVEL
101
HC-BEVEL-101 Bevel Back Weatherboard System Profiles
20/12/11
HC
BEVEL
200
HC-BEVEL-200 Window Head Detail, Aluminium Joinery
20/12/11
HC
BEVEL
201
HC-BEVEL-201 Window Sill Detail, Aluminium Joinery
20/12/11
HC
BEVEL
202
HC-BEVEL-202 Window Jamb Detail, Aluminium Joinery
20/12/11
HC
BEVEL
210
HC-BEVEL-210 Door Head Detail Aluminium Joinery
20/12/11
HC
BEVEL
211
HC-BEVEL-211 Door Sill Detail, Aluminium Joinery
20/12/11
HC
BEVEL
212
HC-BEVEL-212 Door Jamb Detail, Aluminium Joinery
20/12/11
HC
BEVEL
220
HC-BEVEL-220 Window Head Detail, Timber Joinery
20/12/11
HC
BEVEL
221
HC-BEVEL-221 Window Sill Detail, Timber Joinery
20/12/11
yr
op
Product
T n AF a R m D er H ht ig
HP DRAWING INDEX - HC-BEVEL-000 Dwg No. Detail Description
Issued
BEVEL
222
HC-BEVEL-222 Window Jamb Detail, Timber Joinery
20/12/11
HC
BEVEL
300
HC-BEVEL-300 Internal Corner HP110
20/12/11
HC
BEVEL
301
HC-BEVEL-301 Internal Corner Scribed
20/12/11
HC
BEVEL
302
HC-BEVEL-302 Internal Corner Boxed
20/12/11
HC
BEVEL
400
HC-BEVEL-400 External Corner Boxed
20/12/11
HC
BEVEL
401
HC-BEVEL-401 External Corner Soaker
20/12/11
HC
BEVEL
410
HC-BEVEL-410 General Detail Cavity Fix, Stain Finish
20/12/11
HC
BEVEL
411
HC-BEVEL-411 General Detail Cavity Fix, Paint Finish
20/12/11
HC
BEVEL
500
HC-BEVEL-500 Base OF Wall, Concrete
20/12/11
HC
BEVEL
501
HC-BEVEL-501 Base Of Wall, Timber
20/12/11
HC
BEVEL
600
HC-BEVEL-600 Roof/Wall Junction
20/12/11
HC
BEVEL
601
HC-BEVEL-601 Barge Detail, Overhang
20/12/11
HC
BEVEL
602
HC-BEVEL-602 Eaves Detail, Overhang
20/12/11
HC
BEVEL
603
HC-BEVEL-603 Eaves Detail, No Overhang
20/12/11
HC
BEVEL
700
HC-BEVEL-700 Parapet Detail
20/12/11
HC
BEVEL
800
HC-BEVEL-800 Meter Box Detail
HC
BEVEL
801
HC-BEVEL-801 Pipe Penetration Detail
HC
BEVEL
802
HC-BEVEL-802 Pipe Penetration Plan Detail
ci Pa
HC
www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
fic
Cavity Fix Bevel Back Weatherboard System Drawing Index
20/12/11
20/12/11
20/12/11
HC-BEVEL-000 DRAWING
@ A4 SCALE
20/12/11 ISSUED DATE
18.5
140
HP61 Bevel Back Weatherboard - 108mm Cover
18.5
190
HP62 Bevel Back Weatherboard - 158mm Cover
op
18.5
C
190
HP64 Rebated Bevel Back Weatherboard - 165mm Cover
yr
T n AF a R m D er H ht ig
18.5
140
HP63 Rebated Bevel Back Weatherboard - 115mm Cover
18.5
140
HP150 New Bevel Back - 115mm Cover
18.5
190
HP151 New Bevel Back - 165mm Cover
220
18.5
ci Pa
HP152 New Bevel Back - 195mm Cover
fic Cavity Fix Bevel Back Weatherboard System Bevel Back Weatherboard System Profiles www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-100 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
10
40
HP 13 Timber Scriber
17
40
17
60
HP 11 Timber Scriber
HP 12 Timber Scriber
69
18
op
18
C
90
HP202 Cover Batten
HP201 Cover Batten
yr 40
27
T n AF a R m D er H ht ig
HP32 Eaves Moulding
39
39
HP110 Internal Corner Mould
HP69 Grooved Fascia
18.5
180
HP70 Grooved Fascia
Cavity Fix Bevel Back Weatherboard System Bevel Back Weatherboard System Profiles www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
fic
ci Pa
18.5
135
HC-BEVEL-101 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
20
mi n.
Head Flashing Turned up to form Stop End
C yr
op Internal Lining HP62 Bevel Back Weatherboard Flexible Flashing Tape Over Cavity Closure Strip with 15mm drip edge to cladding Ceadar Weatherhead if Required Head Flashing Stop End
10 min. cover
7 min.
5 min
. gap
35 min. cover to Flashing
T n AF a R m D er H ht ig
Breather Type Building Wrap
Aluminium Head Flashing with minimum 15 degree fall & optional Hem Edges as per Table 7 E2/AS1
ci Pa Selected Aluminium Window Joinery Timber Packer
Timber Architrave
fic
Timber Framing
Continuous Sealant Over PEF Rod
Cavity Fix Bevel Back Weatherboard System Window Head Detail, Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-200 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Continuous Sealant Over PEF Rod Timber Architrave Timber Packer Selected Aluminium Window Joinery
yr
Timber Window Support Packer
T n AF a R m D er H ht ig
8 min. cover to Joinery Horizontal Batten under window as nessesary to suit profile Provide window support as required by window manufacturer Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay HP62 Bevel Back Weatherboard Timber Framing Breather Type Building Wrap Internal Lining
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Window Sill Detail, Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-201 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Timber Framing
op
Internal Lining
yr
Timber Architrave Continuous Sealant Over PEF Rod
T n AF a R m D er H ht ig 10 min. cover
20 min Head Flashing extension
Timber Packer Breather Type Building Wrap Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay Line of Head Flashing Over
Selected Aluminium Window Joinery
HP12 Scriber cut to suit profile, fixed and sealed to Weatherboards
fic
ci Pa
Selected Herman Pacific Bevel Back Weatherboard
Cavity Fix Bevel Back Weatherboard System Window Jamb Detail, Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-202 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
20
mi n.
Head Flashing Turned up to form Stop End
C yr
op Breather Type Building Wrap Flexible Flashing Tape Over HP62 Bevel Back Weatherboard Cavity Closure Strip with 15mm drip edge to cladding Ceadar Weatherhead if Required Head Flashing Stop End
10 min. cover
5 min
. gap
35 min. cover to Flashing
T n AF a R m D er H ht ig
Internal Lining
Aluminium Head Flashing with minimum 15 degree fall & optional Hem Edges as per Table 7 E2/AS1
ci Pa
Selected Aluminium Door Joinery Timber Packer
Timber Framing
fic
Continuous Sealant Over PEF Rod
Cavity Fix Bevel Back Weatherboard System Door Head Detail Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-210 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Continuous Sealant Over PEF Rod Timber Architrave
yr
op
Timber Packer Timber Door Support Packer
8 min. cover to Joinery
T n AF a R m D er H ht ig
Horizontal Batten under window as nessesary to suit profile Provide window support as required by window manufacturer Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay HP62 Bevel Back Weatherboard Timber Framing Breather Type Building Wrap Internal Lining
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Door Sill Detail, Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-211 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Timber Framing Internal Lining
op
Timber Architrave
yr
Continuous Sealant Over PEF Rod Breather Type Building Wrap
T n AF a R m D er H ht ig 10 min. cover
20 min Head Flashing extension
Timber Packer Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay
Selected Aluminium Door Joinery Line of Head Flashing Over
HP12 Scriber cut to suit profile, fixed and sealed to Weatherboards Selected Herman Pacific Bevel Back Weatherboard
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Door Jamb Detail, Aluminium Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-212 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Internal Lining
op
HP62 Bevel Back Weatherboard Breather Type Building Wrap Cavibat Cavity Batten
yr
Flexible Flashing Tape Over
35 min. cover to Flashing
T n AF a R m D er H ht ig
Cavity Closure Strip with 15mm drip edge to cladding Ceadar Weatherhead if Required Head Flashing Stop End
10 min.cover Aluminium Head Flashing with minimum 15 degree fall & optional Hem Edges as per Table 7 E2/AS1 Timber Window Head to NZS 3610 Timber Packer Timber Framing
fic
ci Pa
Continuous Sealant Over PEF Rod
Cavity Fix Bevel Back Weatherboard System Window Head Detail, Timber Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-220 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
Timber Packer
C
Timber Sill Board
yr
op
Timber Window Sill to NZS 3610
35 min. cover to Flashing
T n AF a R m D er H ht ig
Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay 150mm Deep Aluminium Sill Tray with 20mm Stop Ends as per Table 7 E2/AS1 Horizontal Batten under window as nessesary to suit profile Timber Framing HP62 Bevel Back Weatherboard Breather Type Building Wrap Internal Lining
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Window Sill Detail, Timber Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-221 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Timber Framing
op
H3.1 Timber Jamb Battens finish clear of Sill Flashing Internal Lining
yr
Timber Window Jamb to NZS 3610 Continuous Sealant Over PEF Rod
T n AF a R m D er H ht ig
Timber Packer
Line of Sill Flashing Under Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay Cavibat Cavity Battens Line of Head Flashing Over
HP202 Cover Batten HP12 Scriber cut to suit profile, fixed and sealed to Weatherboards
ci Pa
20 min. Head Flashing extension
Breather Type Building Wrap
Selected Herman Pacific Bevel Back Weatherboard
fic Cavity Fix Bevel Back Weatherboard System Window Jamb Detail, Timber Joinery www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-222 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Internal Lining
yr
Timber Framing Flexible Flashing Tape
T n AF a R m D er H ht ig
Breather Type Building Wrap continuous around corner
Cavibat Cavity Battens
30 min. cover
HP110 Internal Corner Mould 75 x 75 Hermpac Aluminium Internal Corner Flashing. Hem Edges option as per E2 NZBC Selected Herman Pacific Bevel Back Weatherboard
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Internal Corner HP110 www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-300 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Internal Lining Timber Framing
yr
Flexible Flashing Tape Breather Type Building Wrap continuous around corner
T n AF a R m D er H ht ig 30 min. cover
Cavibat Cavity Battens
75 x 75 Hermpac Aluminium Internal Corner Flashing. Hem Edges option as per E2 NZBC Selected Herman Pacific Bevel Back Weatherboard notched and scribed at corner
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Internal Corner Scribed www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-301 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Internal Lining
yr
Timber Framing Flexible Flashing Tape
T n AF a R m D er H ht ig
Breather Type Building Wrap continuous around corner
Cavibat Cavity Battens
30 min. cover
75 x 75 Hermpac Aluminium Internal Corner Flashing. Hem Edges option as per E2 NZBC
HP201 Cover Batten HP202 Cover Batten Selected Herman Pacific Bevel Back Weatherboard
fic
ci Pa
HP12 Scriber cut to suit profile, fixed and sealed to Weatherboards
Cavity Fix Bevel Back Weatherboard System Internal Corner Boxed www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-302 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
50 min cover
C
HP12 Scriber cut to suit profile, fixed and sealed to Weatherboards HP202 Cover Batten
op
HP201 Cover Batten
yr
75 x 75 Hermpac Aluminium External Corner Flashing. Hem Edges option as per E2 NZBC
T n AF a R m D er H ht ig
Cavibat Cavity Battens Selected Herman Pacific Bevel Back Weatherboard Timber Framing
Breather Type Building Wrap Internal Lining
fic
ci Pa Cavity Fix Bevel Back Weatherboard System External Corner Boxed www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-400 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing 15 min. cover
Corner Soaker Selected Herman Pacific Bevel Back Weatherboard mitred at corner
C
75 x 75 Hermpac Aluminium External Corner Flashing. Hem Edges option as per E2 NZBC Cavibat Cavity Battens
yr
op T n AF a R m D er H ht ig
Timber Framing Breather Type Building Wrap Internal Lining
fic
ci Pa Cavity Fix Bevel Back Weatherboard System External Corner Soaker www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-401 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Internal Lining
32 mm lap
yr
T n AF a R m D er H ht ig
Internal Lining Timber Nogging as Required HP62 Bevel Back Weatherboard Breather Type Building Wrap
Cavibat Cavity Batten
85 x 3.25 HP Crown Head Annular Grooved Shank Nail (or as per E2/AS1 - Table 24)
35 - 40mm
fic
ci Pa Cavity Fix Bevel Back Weatherboard System General Detail Cavity Fix, Stain Finish www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-410 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C T n AF a R m D er H ht ig
32 mm lap
yr
op Internal Lining Timber Nogging as Required HP62 Bevel Back Weatherboard Breather Type Building Wrap
Cavibat Cavity Batten 85 x 3.25 HP Crown Head Stainless Steel Nail punched, paint primed and filled (or as per E2/AS1 Table 24)
35 - 40mm
fic
ci Pa Cavity Fix Bevel Back Weatherboard System General Detail Cavity Fix, Paint Finish www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-411 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
HP62 Bevel Back Weatherboard
yr
Breather Type Building Wrap Internal Lining
Cavibat Cavity Batten
6 mm Framing Overhang
ci Pa DPC
Concrete Slab
Finished Ground Level
150 min. to Permanent Paving or 225 min. to Unpaved Ground as per Clause 9.1.3 of E2/AS1
Cavity Closure Strip with 15mm drip edge to cladding
50 min. below Floor Level
T n AF a R m D er H ht ig
Timber Framing
fic Cavity Fix Bevel Back Weatherboard System Base OF Wall, Concrete www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-500 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Internal Lining
yr T n AF a R m D er H ht ig
Timber Framing Breather Type Building Wrap Floor Lining
Timber Boundry Joist HP62 Bevel Back Weatherboard Cavibat Cavity Batten
50 min below Floor Structure
ci Pa
Cavity Closure Strip with 15mm drip edge to cladding
fic Cavity Fix Bevel Back Weatherboard System Base Of Wall, Timber www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-501 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
Timber Nogging as Required HP62 Bevel Back Weatherboard Breather Type Building Wrap Flexible Flashing Tape Over
C Cavibat Cavity Batten Cavity Closure Strip with 15mm drip edge to cladding
T n AF a R m D er H ht ig
Roofing Underlay continued up behind Flashing Roof Framing Selected roofing with Stop End
130 o Refe r 20 r Fig. 7 & T 0 min. able 7 of E 2
x.
15째 min. slope
5 ma
35 min. above Flashing
yr
75 min Flashing Leg above bottom of Cladding
op
Roof Flashing with Bottom Edge Dressed Down or Notched as per Table 7 E2/AS1
/AS1
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Roof/Wall Junction www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-600 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
Roofing Underlay continued up behind Flashing
50 to 90 min. cover see Table 7 of E2/AS1
Barge Flashing as per Table 7 E2/AS1
Selected Roofing
C yr
op T n AF a R m D er H ht ig Timber Framing
HP70 Grooved Fascia Soffit Lining
HP32 Eaves Moulding Timber Framing
Cavibat Cavity Batten HP62 Bevel Back Weatherboard
Breather Type Building Wrap
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Barge Detail, Overhang www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-601 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C yr
op T n AF a R m D er H ht ig
Soffit Lining HP32 Eaves Moulding Timber Framing Cavibat Cavity Batten Breather Type Building Wrap HP62 Bevel Back Weatherboard
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Eaves Detail, Overhang www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-602 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
1 Re 25 m fer i to n. Fla Fig ure shing 45 c of over E2 \AS 1
C
Timber Purlin Selected roofing
yr
op Selected Gutter
T n AF a R m D er H ht ig
Roofing Underlay
Barge Flashing with 10 mm hem as per Table 7 E2/AS1 Timber Nogging as Required
HP70 Grooved Fascia
Continuous Sealant
Timber Framing Roof Framing
ci Pa
HP62 Bevel Back Weatherboard
Breather Type Building Wrap
fic Cavity Fix Bevel Back Weatherboard System Eaves Detail, No Overhang www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-603 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
Cap Flashing with minimum 5 Degree Fall & minimum cover as per E2/AS1 Table 7. Fix through sides only
C
5째 min. slope
Roof Underlay to provide seperation of metal capping and timber
yr
Refer Table 7 E2/AS1 for minimum required cover
op
H3.2 Treated Timber, or H3 9mm Plywood, or Polystyrene Packer to form slope. Refer Figure 10 E2/AS1 for details Timber Packer
T n AF a R m D er H ht ig
Breather Type Building Wrap Cavibat Cavity Batten HP62 Bevel Back Weatherboard
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Parapet Detail www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-700 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
Timber Nogging as Required Flexible Flashing Tape Over
C
HP62 Bevel Back Weatherboard Cavibat Cavity Batten
Metal Angle sealed and riveted around edge of Meter Box. Refer to Figure 69 E2/AS1
T n AF a R m D er H ht ig
10 min. cover
yr
5 min
. gap
op
Cavity Closure Strip with 15mm drip edge to cladding
Aluminium Head Flashing with 15 degree slope as per E2/AS1 Continuous Sealant Over PEF Rod
Internal Lining Meter Box Continuous Sealant Over PEF Rod Horizontal Batten under Meterbox as nessesary to suit profile Flexible Flashing Tape continuous along sill, 100mm min. up each jamb and 50mm onto face of underlay
ci Pa
HP62 Bevel Back Weatherboard
Breather Type Building Wrap
fic Cavity Fix Bevel Back Weatherboard System Meter Box Detail www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-800 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C op
Cavibat Cavity Batten Cavity Closure Strip with 15mm drip edge to cladding
yr
Support Pipe with Nog under & a screw fixed strap over
T n AF a R m D er H ht ig
Pipe
Continuous Sealant
Rubber Pipe Boot with adhesive colar, fixed to building wrap and sealed to pipe. Refer to Figure 68 E2/AS1 for alternative methods Flexible Flashing Tape Over HP62 Bevel Back Weatherboard Internal Lining Breather Type Building Wrap
fic
ci Pa Cavity Fix Bevel Back Weatherboard System Pipe Penetration Detail www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-801 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE
Notes: - All nail fixings pre-drilled minimum 1mm diameter smaller than the nail gauge. - All products to be precoated & cut edges to be sealed as per Branz Bulletin 411. - All materials and fixtures are to comply with E2/AS1 Clause 2.2 - Provide PVC bond break between H3.1 battens and any flashing
C
Pipe Support Pipe with Nog under & a screw fixed strap over
op
Continuous Sealant Internal Lining
Breather Type Building Wrap
Timber Framing
yr T n AF a R m D er H ht ig
Selected Herman Pacific Bevel Back Weatherboard
Flexible Flashing Tape Over Continuous Sealant
Cavibat Cavity Battens
fic
ci Pa
Rubber Pipe Boot with adhesive colar, fixed to building wrap and sealed to pipe. Refer to Figure 68 E2/AS1 for alternative methods
Cavity Fix Bevel Back Weatherboard System Pipe Penetration Plan Detail www.hermpac.co.nz SUBJECT TO CHANGE WITHOUT NOTICE
HC-BEVEL-802 DRAWING
1 : 2 @ A4 SCALE
20/12/11 ISSUED DATE