TERMSERIES relay modules and solid-state relays | Relay modules
Technical data
1 CO contact AC/DC/UC coil • Space saving, just 6.4 mm modular width • A gNi contact • S crew and tension clamp connection
Technical data Output Max. switching voltage, AC / Continuous current Min. switching power Contact material Mechanical service life Max. switching frequency at rated load Rated data Status indicator Reverse polarity protection Ambient temperature (operational) Storage temperature Humidity
DC Input 12
NC 11
A2 14 11 12
COM
A2
A1
TRS A1
14
NO AC/DC Input
12
NC 11
A2 14 11 12
COM
A2
Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Clearance and creepage distances for control side - load side Surge voltage category Pollution severity
A1
TRS A1
14
NO AC Input + RC Filter
12
NC 11
250 V / 6 A 100 mA / 5 V AgNi 20 x 106 switching cycles 0.1 Hz Green LED Yes -40 °C...+60 °C -40 °C...+85 °C 5...95 % rel. humidity Tu = 40 °C, no condensation CE; cULus; GL 300 V 6 kV (1.2/50 µs) ≥ 5.5 mm III 2
A2 14 11 12
COM
A2
Dimensions Clamping range (nominal / min. / max.) Height x Width x Depth Note
A1
TRS A1
14
NO
mm² mm
Screw connection 1.5 / 0.14 / 1.5 90 / 6.4 / 88
Tension clamp connection 1.5 / 0.14 / 1.5 90 / 6.4 / 88
Accessories and dimensional drawings: refer to the TERMSERIES Accessories page.
Applications 10
DC load breaking capacity
250 V AC
Resistive load
Voltage [V]
Switching Operations
Electrical endurance 7
106
cos φ = 1
400 300 200 100
cos φ = 0.7 105 cos φ = 0.4
T
104
1
2
3
4
5
6
5
6
Current [A]
10
0.1
1
5 Current [A]
Switching Operations
Electrical endurance 107
24 V DC
106
105 acc. to DC 13
104 103
T.40
1
2
3
4
Current [A]
1404630000 – 2012/2013