News Catalogue 2012-2013

Page 96

TERMSERIES relay modules and solid-state relays | Relay modules

Technical data

1 CO contact AC/DC/UC coil • Space saving, just 6.4 mm modular width • A gNi contact • S crew and tension clamp connection

Technical data Output Max. switching voltage, AC / Continuous current Min. switching power Contact material Mechanical service life Max. switching frequency at rated load Rated data Status indicator Reverse polarity protection Ambient temperature (operational) Storage temperature Humidity

DC Input 12

NC 11

A2 14 11 12

COM

A2

A1

TRS A1

14

NO AC/DC Input

12

NC 11

A2 14 11 12

COM

A2

Approvals Insulation coordination (EN 50 178) Rated voltage Impulse withstand voltage Clearance and creepage distances for control side - load side Surge voltage category Pollution severity

A1

TRS A1

14

NO AC Input + RC Filter

12

NC 11

250 V / 6 A 100 mA / 5 V AgNi 20 x 106 switching cycles 0.1 Hz Green LED Yes -40 °C...+60 °C -40 °C...+85 °C 5...95 % rel. humidity Tu = 40 °C, no condensation CE; cULus; GL 300 V 6 kV (1.2/50 µs) ≥ 5.5 mm III 2

A2 14 11 12

COM

A2

Dimensions Clamping range (nominal / min. / max.) Height x Width x Depth Note

A1

TRS A1

14

NO

mm² mm

Screw connection 1.5 / 0.14 / 1.5 90 / 6.4 / 88

Tension clamp connection 1.5 / 0.14 / 1.5 90 / 6.4 / 88

Accessories and dimensional drawings: refer to the TERMSERIES Accessories page.

Applications 10

DC load breaking capacity

250 V AC

Resistive load

Voltage [V]

Switching Operations

Electrical endurance 7

106

cos φ = 1

400 300 200 100

cos φ = 0.7 105 cos φ = 0.4

T

104

1

2

3

4

5

6

5

6

Current [A]

10

0.1

1

5 Current [A]

Switching Operations

Electrical endurance 107

24 V DC

106

105 acc. to DC 13

104 103

T.40

1

2

3

4

Current [A]

1404630000 – 2012/2013


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.