2 FIN™ GLASS RAILING SYSTEM FIN GLASS SPIDER -11/11/22 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com Perforated Metal Glass FIN - AVAILABLE INFILLS Wire Mesh Other mounting options available. Our FIN™ Railing System beautifully combines the industrial look of stainless steel with the warmth of wood to create elegant interior railing applications. FIN™ wood stains are available in Red Oak, Cherry or Maple and the slender post profile provides minimal obstruction to the line of sight,

POST

GLASS & METAL SYSTEM - TECHNICAL DATA

MATERIAL

Composite Stainless Steel (304 or 316) and Wood (Red Oak, Cherry or Maple)

FINISH SIZE/SPACING

#6 Satin + Unstained Wood

Glass Clear, Tinted or Frit

INFILL OPTIONS

2.5”x1.4” @ 5’-0” max. O.C. 4’-6” max. for perforated and wire mesh infill.

Fascia, Top or Core mount.

Min. 3/8” laminated glass with PVB or SGP interlayer ¹

Glass standard thickness: 3/8”, 1/2”, 5/8”, 3/4”

Interlayer standard thickness: SGP: 0.035” , 0.06”

PVB: 0.035”

Perforated Metal 1” wide frame

#6 Satin

Wire Mesh

Stainless Steel Tube

#6 Satin, Powder Coat

Ø1-1/2” or Ø2” for Hand Rail Ø1-1/2”, Ø2” or 2”x1” Rectangular tube for Top Rail

Stainless Steel Tube with LED ² Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD

Wood (Red Oak, Cherry or Maple) ³ Ø2”

#6 Satin Unstained

Wood (Red Oak, Cherry or Maple) with LED Ø2” with LED LINEAR

1. IBC 2015 & newer requires railing glass to be laminated. VIVA recommends SGP for exterior applications.

2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard.

3. Other species available upon request.

3 FIN™
TOP RAIL/HAND RAIL info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com

Glass Infill

AVAILABLE GLASS TYPES:

Clear Monolithic Clear Laminated (PVB or SGP)

Bent Tinted Satin Etched Ceramic Frit

Colored Laminate (PVB only)

LAMINATED GLASS

TOP RAIL

HAND RAIL

FIN POST

LAMINATED GLASS

LEVEL 1 0'-0"

NOM.

TOP RAIL STRINGER

3'-0" 3'-6"

HAND RAIL

Ø2" TUBE Ø1-1/2" TUBE

FINISH FLOOR

2"x1" TUBE Ø1-1/2" iRAIL

TOP RAIL OPTIONS

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

4 G03 G02 G01 5'-0" MAX 5'-0" MAX 1'-0"
1'-0"
VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V A I
2" NOM. 3"
FIN RAILING SYSTEM 3" NOM. GAP
Page 2.1 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. AVAILABLE GLASS TYPES TOP RAIL OPTIONS FIN RAILING SYSTEM GLASS INFILL

Perforated Metal Infill

FIN RAILING SYSTEM PERFORATED METAL INFILL VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

AVAILABLE PERFORATED TYPES

TOP RAIL

HAND RAIL

PA01

4'-6" Ø3 8 " Ø1 2 Ø1 4 " 3 8 "

PMRO-1014 Page 2.2 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com

TOP RAIL

PERFORATED METAL

HAND RAIL

FIN POST

PERFORATED METAL

TOP AVAILABLE PERFORATED TYPES:

STRINGER

SECTION VIEW

TOP RAIL OPTIONS

5
PA03 PA02
1'-0"
1'-0"
2"
3"
9 16 1" 1 16 " (14 GA) VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM
3"
NOM.
NOM.
FIN RAILING SYSTEM
NOM. GAP
MAX 4'-6" MAX LEVEL 1 0'-0" FINISH FLOOR 3'-0" 3'-6"
RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2" iRAIL 1" 13 4 " 5 16 " 1 8 " 9 16 " 11 16 " 3 8 5 8 " 7 16 " 13 16 7 8 1 1 16 PMSL-0325 PMRO-0610
VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. PMSQ-1013 PMRO-1217 PMSL-1122

Wire Mesh Infill WIRE MESH

LEVEL 1 0'-0"

TOP

3'-0" 3'-6"

WIRE

HAND RAIL

Ø2" TUBE

Ø1-1/2"

2"x1" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

TOP RAIL OPTIONS

TOP

RAIL OPTIONS

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

6 PA03 PA02
4'-6" MAX 4'-6" MAX 1'-0" 1'-0"
PA01
FIN
HAND
2" NOM. 3" NOM. WM-10 1 5 16 7 16 WM-15 WM-13 WM-17 WM-19 WM-20 WM-21 9 16 " TYP. 1" TYP. VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I
3" NOM. GAP WM-11 WM-12 WM-14 7 16 11 16 1 2 13116 33 4 " 7 16 21 8 7 8 1 7 8 1 7 8 5 8 9 16 " 1 1 16 13 16 15 16 3 8
POST TOP RAIL
RAIL
FIN RAILING SYSTEM
TUBE
MESH
RAIL STRINGER Page 2.3 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. WIRE MESH INFILL FIN RAILING SYSTEM
7 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com FIN WIRE MESH RAILING SYSTEM

FIN RAILING SYSTEM

Mounting Condition, Top Mounted Post

Anchored to Concrete ¹ - $ ²

Detail# FN-T01

Welded @ Embed Plate - $

Detail# FN-T04

(1)

(2) $ to $$$: Indicates mounting type comparative cost

Embed Plate (By others)

Cored into Concrete - $$

Detail# FN-T02

Welded @ Steel Channel - $

Detail# FN-T03

8 6" MIN.
3"
5" MIN. 6" MIN. 5" MIN. 5" MIN. 5" MIN.
MIN.
Min. 4000 PSI concrete, Typ.
2 " MIN. 3" MIN. VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I
61
RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. Anchored to Concrete Welded to Steel Plate - $ Detail# FN-T06 3/8" BENT PLATE (BY OTHERS) 23 4 " 6" MIN. Anchored to Concrete Slab on Deck - $$ Detail# FN-T05
VIVA
Page 3.1 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. FIN RAILING SYSTEM MOUNTING CONDITION, TOP MOUNTED POST

Anchored to Concrete ¹ - $$$

Detail# FN-F01

Welded @ Steel Tube - $$

Detail# FN-F04

Welded @ Embed Plate - $$

Detail# FN-F02

Embed Plate (By others)

Welded @ Steel Channel - $$

Detail# FN-F03

(1) Min. 4000 PSI concrete, Typ.

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT,

9 6" 6" 6"
6" MIN.
6" MIN. 6" VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A
6" 6"
FIN RAILING SYSTEM
PLEASE CONTACT VIVA RAILINGS. Welded @ Pour Stop - $$ Detail# FN-F05
REBAR (BY
THICK POUR STOP
OTHERS) 3" MIN. 3" MIN. Mounting Condition, Fascia Mounted Post Page 3.2 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. FIN RAILING SYSTEM MOUNTING CONDITION, FASCIA MOUNTED POST
STUD or DEFORMED
OTHERS) 3/8"
(BY

30°

22°

10 VIVA RAILINGS, LLC 1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com V V A TM I FIN RAILING SYSTEM
Ø11 2 " 36 " TO FF TOP RAIL ILLUMINATED HANDRAIL 23 4 " 4 2 " TO FF Illuminated Toprail Option Illuminated Handrail Option iRAIL POD ORIENTATION OPTIONS 18" 24" OR 36" iRAIL POD SPACING OPTIONS POD iRAIL Linear
Illuminated Railing
ASYM. LINEAR SYM. LINEAR iRAIL LINEAR ORIENTATION OPTIONS
ASYM. POD SYM. POD See Viva iRail Railing System for more info Page 4 of 4 2/5/2024 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com FIN RAILING SYSTEM iRAIL LIGHTED RAILING SYSTEM ILLUMINATED RAILING
11 FINISHING OPTIONS #6 SATIN info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com FIN GLASS RAILING SYSTEM
12 FIN GLASS RAILING SYSTEM ROBB & STUCKY SHOWROOM info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com General Contractor: Fisher Contracting Corporation Architect: MHK Architects ROBB & STUCKY SHOWROOM - BOCA RATON, FL
13 FIN GLASS RAILING SYSTEM UNITED HEALTH SERVICES - VESTAL info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com General Contractor: F.E. Construction Architect: Chianis Anderson Architects UNITED HEALTH SERVICES (UHS) VESTAL - VESTAL, NY
151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 (Dallas/Fort Worth Metroplex) PH: 972.353.8482 | info@vivarailings.com vivarailings.com NORTH AMERICA OPERATIONS Dallas/Fort Worth, TX San Diego, CA Atlanta, GA Orlando, FL New York, NY Washington DC Regional Locations Version:120423 Kansas City, KS ICC-ES 4405 Certified SHOE™ Structural Glass Railing System The American Institute of Architects The California Contractors State License Board Certified Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019 Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211 LEED Material & Resources Credits 4.1 and 4.2

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.