Trane air cooled scroll chillers 20 100 tons, 50hz

Page 2

TM

SYSTEM CGAP/H 50Hz Air-Cooled Chillers Introducing the Trane VWV system (Variable Water Volume)....... More for less indoor multi-system

Footprint...... We consider your space just as precious. Central to design of any project is the operating envelope of the air-cooler packaged chiller. Trane CGAP/H air-cooled chillers have a compact footprint to make the most efficient use of this available installation space.

Trane’s time-tested reliable chilled water system offers comfort, reliability and flexibility , all at the same time. Very few other systems do. Here is why ..........

Brazed plate heat exchanger with integrated distributor

With brazed corrugated stainless steel plates, this compact heat exchanger offers a highly efficient heat transfer rate that is less susceptible to erosion and corrosion while maintaining a homogeneous refrigerant distribution.

TRANE MICROPROCESSOR CONTROLS The brains behind the chiller are based on a PID state of the art microprocessor that allows diagnostics and remote alarm, while fully protecting the chiller from operational problems. Capabilities of the controller includes processing, monitoring, and diagnostics to ensure effective control over compressor

Mechanical Specification CGAP 025 to CGAH 150 GENERAL:

EVAPORATOR

Units shall be mounted on heavy gauge steel mounting and shall be weather -

The evaporator shall have independent refrigeration circuit. The evaporator shall be of plate - frame type design with a waterside working pressure of 350 psig and refrigerant side working pressure of 300 psig. For units with two evaporators, the connecting water manifold shall be provided. Evaporator shall be insulated with a close - cell insulation.

proofed. Units shall include hermetic

scroll compressors, plate fin condenser coil, fan(s) and motor(s), controls and completely factory installed operating charge of oil and R-22 refrigerant. The units shall accept a single point, 3-phrase power connection . All units shall be run tested at the factory. R-407C refrigerant shall be an option.

CONDENSER FAN AND MOTOR CASING Unit casing shall be constructed of 1.2 mm zinc coated heavy gauge galvanized steel. Exterior surfaces shall be cleaned, chemically treated and finished with weather - resistant baked polyester powder finish. Unit shall have removable panels for access to major components and control. Controls shall be mounted in weatherproofed cabinets. The removable panels shall be held in place by “rapid access” clips and Allen key arrangements.

REFRIGERATION SYSTEM

Serviceability...... Something which we never miss

Reliability .....Built into the heart of the machine The compressors used are proven world class hermetically sealed compressors. Scroll compressors used on these chillers, are among the industries, most resilient and efficient compressors. The technology ...... From the legendary Trane chiller stable control Complete factory - wired with necessary capacity and safety controls. Enclosed in a weather-tight control panel with knockouts for jobsite installed wiring to ensure smooth and trouble - free installation and operation.

The control panel and unit panels are completely removable for service accessibility and convenience “ Rapid access” clips and Allen key arrangement allows fast access to the major components in the unit. Installation......Designed for your convenience The unit arrives at jobsites fully assembled tested, charged and ready to provide chilled water. No messy field assembly or refrigerant charging is required. Further, the unit has been designed for single power and water connection.

staging, resulting in efficient and accurate chiller operation. A higher end Trane microprocessor version is available that allows communication with detailed water, refrigerant pressures and electrical amp realtime readouts, and for more complex chiller applications.

HFCA & HCCA :Ranging from 300 to 2,500 cfm, highly flexible low height fan coil units are designed to meet tight ceiling space applications.

Units shall have independent refrigeration circuit(s), system leak tested at the minimum 300 psig working pressure. Each refrigeration circuit shall have an internal sub cooling circuit. Refrigeration filter drier, high and low pressure schreder valve and sight glass with moisture indicator shall be provided as standard. Scroll compressor, shall be piped in parallel, with a passive oil management system. Passive oil management system maintains proper oil levels within compressors and has no moving parts. Each refrigeration circuit will include an externally equalized expansion valve. The standard leaving chilled water temperature is 41 to 54 deg. F.

Direct drive, statically and dynamically balanced propeller fan with aluminum blades shall be used in draw-thru vertical discharge position. The motor shall be 3 phase and for continuous air over motor duty. Motor overload protection shall be provided as standard.

CONTROLS ( Start ) Compressors contactors and controls are in weather-tight enclosure with knockouts for site installed wiring. Control wiring shall be 240V Microcomputer. Controls shall provide all control functions including leaving chilled water functions, temperature control, automatic compressor sequencing load limiting and anti-recycle functions. Failure protections, shall include chiller freezing compressor running overcurrent, phrase loss phrase reversal, under and over voltage , loss of charge high motor winding temperature, high and low refrigerant pressure. Controls shall be of a start stop switch, a leaving water temperature setpoint adjustment, a dT adjustment and a digital display. Display readouts shall include operating codes water temperature setpoint operating temperatures other operating readouts and diagnostic codes. The units shall have a single-point, three phrase power connection . The unit shall accept chilled water flow interlock from a factory installed flow switch.

OPTIONAL FEATURES COMPRESSORS Scroll compressors have simple mechanical design which provides inherently low vibration. Scroll compressors include centrifugal oil pump, built-in dirt separator, oil levels sight glass and oil charging valve. The direct -drive suction gas - cooled compressor motor has a voltage utilization range of plus or minus 10 percent of nameplate voltage. Motor winding thermal overload and over current protection shall be included as standard.

Corrosion-resistant finned condenser coil

BD : Belt-driven blower coil air handlers for flexible installation. Convertible units (horizontal and vertical floor configuration) with range of airflow between 3,000 cfm and 7,000 cfm comes factory fitted with motor and drive assembly.

LWHA: Commercial Slim, Single Wall Ceiling Duct Units from 400 - 4,000 cfm. Augurs well for applications in colleges, factories, office buildings, complexes, hotels and theaters.

A layer of resin is coated onto the surface of the fins to increase resistance to corrosion in harsh environmental conditions. A 500 hours, salt-spray test (in accordance to JIS-Z-2371) and humidity test (at 50 deg. C, 98% relative humidity) had been performed to confirm the corrosion-proof property of this coating.

FLOW SWITCH This is a factory installed standard which indicate loss flow, to ensure against freezing.

CONDENSER COIL Coils shall be 3/8 ” copper tubes mechanically bonded to configured aluminum plate fin as standard. Factory proof and leak pressure tested at 450 psig.

Aqua stylus: Convertible chilled water fan coils designed for capacities ranging from 10 to 36 Mbh. Comprise optimum blend of advanced technology, attractive design, outstanding value and solid reliability.

WATER STRAINER Strainers are a requirement for all water evaporators. These are available as a factory ship standard.

CLCP : Designed for superior air quality and water management system. A showcase appearance with Intelligent System Control option among the multitude of other options. These air handlers are designed for both commercial and stringent varied industrial applications. Airflow ranges is from 1,000 to 100,000 cfm.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.
Trane air cooled scroll chillers 20 100 tons, 50hz by Education Vietmastec - Issuu