Don’ t forget to order cement. rigid nonmetallic conduit is normally supplied in standard 10' lengths, with one belled end per length. support straps should allow for lineal movement caused by expansion and contraction. conduit & fittings — carlon ® pvc elbows, conduit & fittings elbows, sweeps and accessories pvc conduit repair system instructions apply a uniform coat of cement. • sunlight resistant • rated for use with 90° c conductors • superior weathering characteristics etl listed to ul 651 in compliance. safety nonmetallic conduits are nonconductive, assuring a safe system. schedule pdf 40 cellular core utility conduit uses. schedule electrical conduit, p& c duct, split duct, multi- gard, boregard, pv mold, intra- gard, telephone duct and conduit elbows & fittings. maximum ambient temperature is 122° f ( 50° c). for direct earth burial and concrete encasement, specifically designed for the power utility specifications. prime pvc conduit pdf • power and utility companies were supplied with underground pvc duct and fittings. for specific requirements, it may be produced in lengths shorter or longer than 10', with or without belled ends. insert plug to keep conduit clean/ dry through balance of rough- in. push conduit firmly into fitting while rotating conduit about one- quarter turn to spread cement evenly. prime conduit p& c® ( power & communications) duct and fittings are designed and formulated specifically for concrete encased and direct burial applications of power utility primaries, secondaries, street lighting and distribution systems. the following is a list prime pvc conduit pdf of the product numbers for each 20” conduit. prime conduit' s schedule 40 & 80 pvc conduit is a listed raceway for pdf electrical conductors and cables. 40 and schedule 80 rigid pvc nonmetallic conduit. 7 tensile strength ( psi) @ 73. apply coat of solvent cement to end of conduit to the length of socket to be attached. interpace oklahoma city, okfax. the measurements for each trade size listed above are the same with the exception of the length ( l) which is 240 inches. place 5- foot section over cable and snap the two sections together. use rnc fittings with schedule. 1 cut broken conduit off flush. 23240 chagrin blvd suite 405 cleveland, ohwww. place another 10- foot split duct section over the open half of the bottom section, butt the ends tightly together and snap the sections together. support of prime conduit rigid nonmetallic conduit pdf in aboveground installations. place strap about one foot from the end and another strap about a foot from the joint where the ends of the top sections will butt. • for the communications industry, pvc conduit and fittings were made available to telephone and cable companies for underground cable installations. * prime conduit’ s bell depth meets and/ or exceeds nema tc- 2 minimum bell depth standards. support of carlon rigid nonmetallic conduit in aboveground installations. pvc schedule 40 conduit belled end- 20’ lengths cantex schedule 40 conduit is available in 20’ lengths with the exception of the ½ inch trade size. rigid pvc fittings and junction boxes shall be used for all outlets, pull boxes and junction points. prime conduit p& c duct complies with nema standard tc- 6 & 8, and astm f- 512 for utility duct. our products include. push and rotate conduit until the ends meet. molded end bells meet nema tc- 3. end bells shall be intended for connection to the end of rigid pvc conduit entering a manhole or handhole enclosure but not a junction box. cellular core pvc utility conduit. all wiring shall be installed in rigid pvc conduit and secured to pvc boxes and cabinets by means of proper fittings. jm eagle™ pvc schedule conduit is manufactured in accordance with the following specifications: ansi/ ul 651 nema tc- 2 support of jm eagle™ pvc conduit in above ground installations mechanical properties astm typical value specific gravity d792 1.
ease of installation nonmetallic conduits are 1/ 4 to 1/ 5 the weight of metallic systems, can be installed in less than half the time, and are easily fabricated on the job. special conduit sizes will be quoted on request. once rough- in is complete, remove plug. we do not make pre ssure rated conduits. material shall comply to nema specification tc- 2 ( conduit), tc- 3 ( fittings) and ul 651 ( conduit) and 514b. conduit shall be prime conduit schedule 80, rated for use with 90° c conductors, etl listed to ul 651 or approved equal. pvc conduit schedule 40 pvc rigid nonmetallic conduit heavy wall epc listed for underground applications encased in concrete or direct burial. therefore, we do not provide technical information such as burst strength. wipe the excess cement left in brush to the inside of coupling. only pressure rated pvc conduit or tubing can be used for air pressure applications. applicable standards: ul listed ( ul 651) nema tc- 3 ( couplings, female adapters, terminal adapters, box adapters, end bells only) jeremy zeliff quality manager prime conduit 6500 s. acceptable dimensions in inches of integral bell per * nema tc- 2. all boxes, access fittings and covers shall be furnished with threaded brass inserts, brass screws and pvc gaskets. end bells are fittings intended to provide a bushed opening at the open end of a length of rigid pvc conduit. impact resistant prime conduit schedule 40 and schedule 80 nonmetallic conduits are resistant. rotate quarter turn. electrical distributors and contractors were provided with a broad line of pvc conduit and fittings. also for use in exposed or concealed applications above ground. plastic conduit should always be installed away from steam lines, etc. end bells & fabricated end bells.