UV Systems For Air Catalog

Page 1

UV Systems For Air


INDEX UV Systems For Air ............................................................................................................................................... 3


UV Systems For Air Code: 24024001

Portable UV sterilizer for air

Features: - 99% destruction of bacteria, viruses. - Quick sterilization. - Safe and durable. Wavelength: 270-285nm Lamp power: 100mA Material: PC (polycarbonate) Battery capacity: 500mAh (lithium battery) Applications: Maternal and infant supplies, office supplies, Express box, bathrooms, furniture surfaces, hotels. Code: 24024002

Portable 2,5W. UV-Ozone system for air

Variants Code

Description

24024002-01

Portable UV-Ozone system for air 2,5W

Through the design of ultraviolet and ozone in a synchronized way, ultraviolet rays can kill microorganisms by destroying the DNA and RNA of microorganisms. Some kind of UV lamps can emit both 254nm and 185nm UV light. 254nm is the irradiation necessary for kill bacteria, 185nm is the irradiation for generate ozone in the air. This systems equip with cold cathode lamp which can emit 254nm and 185nm uv light. That’s why it can generate ozone. Features: - 99% destruction of bacteria, viruses. - Quick sterilization.

19 August 2021

3/8


Power: 2.5W. Voltage: 5V. Material: ABS (acrylonitrile butadiene styrene) Application area: Code: 24024003

Portable 40W. UV system for air with remote control

Variants Code

Description

24024003-01

Portable 40W. UV system for air with remote control

Features: - 99% destruction of bacteria, viruses in the air. - Keep the air cycle in motion to obtain complete sterilization. - 3 time settings. 30/60/120 minutes, also 24 hours a day, 7 days a week. - 3 speed settings. - H type germicidal lamp, high transmission compact. - Integrated fans for air ventilation. - Retractable handle for easy movement. Power: 40W. Voltage: 220V. Frequency: 50/60Hz Room sanitization times: < 20m2 = 30 minutes 20-40m2 = 60 minutes 40-60m2 = 120 minutes > 60 m2 = 24h / 7 days Operating mode: - Stand-by mode for closed fans (IMG. A). - Open fan operating mode (IMG. B). - 30 seconds delay in going into operation.

19 August 2021

4/8


Code: 24024004

Trolley UV system from 60W. to 120W. for air

Variants Code

Description

24024004-01 24024004-02 24024004-03 24024004-04 24024004-05 24024004-06

Trolley UV system for air 60W. (30W.x2) without infrared sensor, alarm and time delay switch Trolley UV system for air 60W. (30W.x2) with infrared sensor, alarm and time delay switch Trolley UV system for air 120W. (30W.x4) without infrared sensor, alarm and time delay switch Trolley UV system for air 120W. (30W.x4) with infrared sensor, alarm and time delay switch Trolley UV system for air 120W. (30W.x4) without infrared sensor, alarm and time delay switch Trolley UV system for air 120W. (30W.x4) with infrared sensor, alarm and time delay switch

Voltage: 220V. Frequency: 50Hz. Input power: 180VA Lamp power: from 60W. to 120W. UV lamp working life: 5000 hours Applicable static area: from 30m3 to 60m3 UV wavelength: 253.7nm Adjusted to various angles: 90°, 135°, 180° Material: carbon steel or stainless steel Timer: 0-120-1440 min. Ultraviolet radiation (distance of 1m.) 107µW/cm2 (Single tube) Code: 24024005

UV system from 16W. to 78W. for air

Variants Code

Description

24024005-01 24024005-02 24024005-03 24024005-04

UV system 16W. (1x16W.) for air UV system 32W. (2x16W.) for air UV system 44W. (2x22W.) for air UV system 78W. (2x39W.) for air

Internal sterilization chamber system using UV-C lamps. Air is conveyed to the internal sterilization chamber built of highly reflected 304 stainless steel, further amplifying irradiation UV-C.

19 August 2021

5/8


Concentrated irradiation of ultraviolet rays eliminates all microbial agents including pathogens. It can operate constantly and continuously in environments with people, ensuring maximum protection. Technical specifications: Turn on/off on standby: Bright button. Turn on/Remote shutdown: Radio comand. Lamp on light UV-C.: Green led for single lamp. Acoustic and Visual Alert (Led Color Change): System not working. Lamp consumption indicator: Count hours. Dust filter. UV system 16W. (1x16W.) for air: * Power supply: 200-240V 50/60Hz 0,25A * Rating power: 49W. * Treated air flow: 36m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 700 L. x 290 H. x 120 D. UV system 32W. (2x16W.) for air: * Power supply: 2x200-240V 50/60Hz 0,25A * Rating power: 80W. * Treated air flow: 64m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 700 L. x 290 H. x 120 D. UV system 44W. (2x22W.) for air: * Power supply: 2x200-240V 50/60Hz 0,25A * Rating power: 130W. * Treated air flow: 88m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 810 L. x 290 H. x 120 D. UV system 78W. (2x39W.) for air: * Power supply: 2x200-240V 50/60Hz 0,25A * Rating power: 160W. * Treated air flow: 160m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 1.200 L. x 290 H. x 120 D. Applications Offices, hospitals, schools, laboratories, restaurants, factories and public transport, where the concentration of people is amplified and continuous. Code: 24024006

UV-Ozone system from 32W. to 117W. for air

19 August 2021

6/8


Variants Code

Description

24024006-01 24024006-02 24024006-03 24024006-04

UV-Ozone system 32W. (2x16W.) for air: UV-Ozone system 48W. (3x16W.) for air UV-Ozone system 66W. (3x22W.) for air UV-Ozone system 117W. (3x39W.) for air

Internal sterilization chamber system using UV-C lamps and Ozono production. Air is conveyed to the internal sterilization chamber built of highly reflected 304 stainless steel, further amplifying irradiation UV-C, to which it is added the emission of ozone programmed (in minutes and intervals) via dedicated controller, The system sterilizes the air through the irradiation of ultraviolet rays that constantly eliminate viral pollution, avoiding contamination on the environment during working hours; sanitizes surfaces through ozone, during the interval or closing hours, in order not to expose people to it. Technical specifications: Turn on/off on standby: Bright button. Turn on/Remote shutdown: Radio comand. Lamp on light UV-C.: Green led for single lamp. Acoustic and Visual Alert: System not working. Lamp consumption indicator: Count hours. Dust filter. UV-Ozone system 32W. (2x16W.) for air: * Power supply: 2x200-240V 50/60Hz 0,25A * Rating power: 49W. * Treated air flow: 64m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 700 L. x 290 H. x 120 D. UV-Ozone system 48W. (3x16W.) for air: * Power supply: 3x200-240V 50/60Hz 0,25A * Rating power: 80W. * Treated air flow: 96m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 700 L. x 290 H. x 120 D. UV-Ozone system 66W. (3x22W.) for air: * Power supply: 3x200-240V 50/60Hz 0,25A * Rating power: 130W. * Treated air flow: 132m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 810 L. x 290 H. x 120 D. UV-Ozone system 117W. (3x39W.) for air: * Power supply: 3x200-240V 50/60Hz 0,25A * Rating power: 160W. * Treated air flow: 234m3/h. * Philips average lamp life: 9.000h. - max. 1 year * Dimensions (mm.): 1.200 L. x 290 H. x 120 D. Applications Offices, shops, restaurants, bars, supermarkets, laboratories, medical offices, hairdressers and public transport.

19 August 2021

7/8


Powered by TCPDF (www.tcpdf.org)


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.