SAKURA HOME LIFT

Page 1

Excellence Award Taiwan

SAKURA Elevator Co., Ltd.

Japanese High-end Safety,

International Elevator Company

SAKURA Elevator has markets in Asia, Singapore, and more than 30 countries from different regions, like Middle East, North / South America, and Africa. We also set up branches in different areas (including Japan, Taiwan, Singapore, Hong Kong, China, Indonesia, Guam, etc.)

1

Safety, and Quality

P 3-8

P 9~15

P 16~18

P 19~20

P 21~24

P 25~30

Index

Our Feature & HAL Panoramic Lift

Stylish Home Lift

Operating Panel & Door Type Options

Materials & Floor Options

Optional Devices

Specifications & Function Descriptions

2
High-end Technology,

Reasons for Choosing SAKURA Elevator:

Multinational Certificate

Products with certificate of CE, UL, JIS, and standards from different countries. Worldwide markets including Japan, Singapore, Southeast Asia, Middle East, America, and Africa.

Cabin Dimension Customization

Capable of providing best costomized solution according to shaft size and car size from clients.

Elevator Style Customization

With professional designers, able to match the elevator with interior design.

Excellent Protection

Various safety devices, including UCMP, SMS system, flood detector, earthquake detector, and 2 in 1 safety door edge.

3
4

Japanese High-End Technology, Safety, and Quality

5
6

HAL Aluminum Shaft Elevator

Integrated Design

Type : Machine Roomless

Capacity : Under 450Kgs

Speed : 30-45 M/min

Stops : 6 Floors Maximum

Travel : 18 Meters Maximum

Shaft Wall : Glass / Aluminum Alloy Plate

Aluminum Shaft Structure : Spray Painting

7

SAKURA Integrated Elevators

◆ Integrated Design, Postmodern Style

◆ Transparent Vision, Wider and Brighter Space

◆ Less Space Required

◆ No Extra Fee on Shaft Construction

◆ No Grouting, Least Affection to Residents

Elevator Structure Certificate from Singapore

8
9
10

G9 Pitless Elevator

11
12
Power Saving Light Curtain Intercom System GSM System
Wheelchair Accessible Lighting
Landing Panel SHP 004 Power Saving Light Curtain Intercom System GSM System Wheelchair Accessible Lighting Landing Panel SHP 004 Power Saving Light Curtain Intercom System GSM System Wheelchair Accessible Lighting Landing Panel SHP 016 SCP004 SCP002 SCP015 SHP004 SHP002 SHP006 SCP013 SHP016

Landing Door Type

Glass Type

Standard Door Type

17
LSE-01 LSE-005 LSE-006 LSE-007 LSE-02 LSE-03 LSE-04

Jamb Type

18
Standard Jamb JSE-01 Wide Jamb JSE-02 Maintenance Jamb JSE-03 120 JJ=800 120 1040 HH=2000 25 120 JJ=800 120 1040 HH=2000 25 1550 50 120 JJ=800 HH=2000 510 1430 70 Control Panel 400 800 510 120 1430 200 400 200 800 120 120 1040 60 800 400 120 120 1040

Materials & Colors

Pattern Steel Plate

The colors and patterns above are for reference only, actual products are considered as final.

19
LG-01 LG-04 LNA-24 LNW-1 LNA-14 LC-14 LNA-15 LNW-24 LW-6920 LNA-18 LC-108 LW-9284

The colors and patterns above are for reference only, actual products are considered as final.

20
X-853 X-859 X-860
Smart Maintenance System SMS Elevator Malfunction Report Center Detecting a person's coma Rescuing trapped people Family or Friends Elevator failure or accident Maintenance Staff 4-1 Maintenance Staff will rescue with family Monitoring Center Automatic Detection Immediate Report 1 2 4-3 3 5 6 Elevator Monitoring Real-time Elevator Monitoring, Instant Reporting on Various Malfunctions. Taiwan Excellence Awarded Optional 21 Safety Equipment
Global System for Mobile Communication Optional GSM Sakura Elevator Monitoring Center Building Security Family or Friends Maintenance Staff 100% Safety! Automatic Detection Immediate Report GSM + SMS No Need to Call for Elevator Failure or Rescue Service. Automatically contacts family members, control room, maintenance staff, and monitoring center. + 22

Safety Equipment

Double Protection Double Safety Double Protection,

Imported from Japan, Sold by Sakura

Earthquake Occurs During Elevator Travelling

P Wave (Primary Wave) Detected

Earthquake Intensity Identified by Sensor

Warning Broadcasting + Display

Approaching Nearest Floor + Opens the Door

Power Shutdown

S Wave (Secondary Wave) Arrives After the Earthquake

Passengers Have Left for Evacuation

Elevator Self-testing. Passed > Restart Failed > Waiting for Maintenance

Earthquake Detector Earthquake Detector

Elevator Safety Protection

from
2 in 1 Light Curtain Earthquake Detector
Infrared Light Curtain Imported
Switzerland
Standard
Optional
23

UCMP (Unintended Car Movement Protection)

Flood Detector

Make Flooding No Longer A Problem

「UCMP Mechanism」

Controller drives the car to safe floors.

Car moves to safe floor and opens the door, then shut off for safety concern.

Mechanism Activated by UCMP Independent Control

Dual Brake System or Backup Rope Gripper Activated

Stops The Car From Moving

Broadcaster sounds the alarm and sends signals to controller.

Passengers Saved

Sensor sends signals to broadcaster while detecting flood in the pit.

Multinational Patents, Exclusively Sold in Taiwan.

Pit
7.5
Dual Brake Motor Rope Gripper Cabin Position Detector Independent Control
Sakura UCMP activates to stop the car from moving while detecting irregular movement over
cm.
Optional Optional
While Door
Protection
Car Movement >7.5cm
Opened Irregular Movement Detected by UCMP
24

Single Entrance (Steel Structure / RC Structure)

Double Entrance (Steel Structure / RC Structure)

L Type Entrance (Steel Structure / RC Structure)

Other Floors

25 TRAVEL
Drawing
Plain View Drawing
26 Single Entrance(W*D) 1550*1250 1750*1750 Double Entrance(W*D) 1550*1450 1750*1950 L Type Entrance(W*D) N / A 1950*1850 Pit O H 550 1200 1500 Shaft Dimensions 1550*1550 1600*1550 1600*1550 1550*1750 1600*1750 1600*1750 3200 3600 3800 1700*1650 1750*1650 1750*1650 Door Opening Car Dimension 900*900 Car Net Height Entrance Dimension Motor Capacity KW(HP) 2 2KW 3KW 2 2KW Wire Ropes Guide Rails: Car / Counterweight Power / Lighting(A) Power Supply (V) Single Phase 220 / Single Phase110、3 Phase 220 / Single Phase110、3 Phase 380 / Single Phase110 10mm*4 8K/8K 13K/13K 30A/20A 40A/20A 50A/20A 800*2000 800*2000 Technical Parameters 1 5KW 3 7KW 5 5KW 8mm*3 8mm*4 Car & Entrance 900*1200 1000*1400 2100 2200 8mm*5 2 S Type Capacity 140 200 Speed 30 45 30 45 30 45 45 30 Maximum Travel Maximum Stops Drive Basic Data 320 400 450 550 20 15 18 21 5 6 7 VVVF HRC Machine Room Less Home Lift HRC-G3 HRC-G3X HRC-G4 HRC-G4X

OBH Specifications

OBH Elevator Specifications

27
Capacity Type OB H OB H TYP E Item Speed 45 m / mi n 60 m / mi n Speed Door Opening Entrance Dimenson Car Dimenson Hoistway (Kgs.) 450 550 OH(mm) PIT(mm) 4800 1600 5000 1600 m/min 45-60 45-60 mm CO CO JJ 800 800 HH 2100 2100 AR 1240 1240 HC 2300 2300 R 2300 2300
HC=2300 HH=2100 HH=2100 PIT TR TH O.H
Vertical View of Wall Side

HAL Specifications

H AL Aluminum Shaft Elevator Specifications

28
Type Capacity Speed Maximum Travel Maximum Stops Counterweight Door Opening Car Dimension Car Net Height Entrance Dimension Motor KW(HP) Wire Ropes Guide Rails: Car / Counterweight Power / Lighting power(A) Power Supply (V) Shaft Dimensions Pit OH 2 0 3 0 45 3 0 45 1 5
HAL-G3 HAL-G3 X HAL-G4 Basic Data 1 4 0 2 0 0 3 2 0 4 0 0 / 450 2 0 Car & Entrance 9 0 0 * 9 0 0 Side of the car 6 Technical Parameters 1 5 KW 1 5 KW 2 2 KW 3.7KW 8 m m* 3 8 m m* 3 8 m m* 4 8 m m* 5 Remarks Controller is installed above the landing door header of top floor, or space besides the shaft on top floor. If shaft is installed outdoors, top cover and leak proofing work are required. 5 5 0 1 00 0 320 0 700 3100 550 2900 Shaft Request 1 6 5 0 * 1 3 5 0 1 6 5 0 * 1 6 5 0 1 6 5 0 * 1 6 5 0 1 7 5 0 * 1 6 5 0 3 40 0 9 0 0 * 1 2 0 0 2 S 2 1 0 0 8 0 0 * 2 0 0 0 8 K/8 K 3 0 A / 2 0 A 4 0 A / 2 0 A Single Phase 220 / Single Phase110、3 Phase 220 / Single Phase110、3 Phase 380 / Single Phase 110

Feature Description

Automatic Levelling

Auto levelling and re-levelling, ensuring level between car and landing door sill.

Emergency Car Lighting

Emergancy in car lighting during power failure of the main building power supply.

Door Safety Detector

A self test feature that monitor door safeties upon switching from inspection to automatic mode.

False Call Cancelling

Cancelling registered call at the Car Operating Panel (COP) by double tapping registered floor button.

Energy Conservation

Lift inverter goes into sleep mode together with light and fan within the car will be switched off automatically after a pre-determined period of time, after answering the last call.

Main Floor Parking

Lift will return to main floor (pre-determined) after last registered call.

Door Hold

Door Nudging Feature

Extending door opening time by pressing "Door Open" and "Call Button" on the Car and Hall Operating Panel respectively.

If an obstacle prevents the door from closing, the door will repeatedly open and close until the object is removed.

Overload Weighing Device

Anti-Nuisance

Overload safety device that render the lift to be inoperative and an activated alarm.

Registered calls will be cancelled in the event that the load is lesser than expected within the lift car.

Car Reverse Direction

Re-Leveling Function

Reverse direction calls will be cancelled upon completion of the last registered call of the same direction.

Auto re-leveling in a low speed when a car stops between floors due to malfunction.

Car Door Safety Edge

Emergency Intercom System

Mechancial safety device in additon to lift curtain sensor.

Emergency communication device with someone outside the lift.

Standard 29

Feature Description

Automatic Fault Logging Provide comprehesive fault data on recent breakdowns (up to 20 fault tracking).

Manual Operation Switching the automatic lift car operation to manual mode.

Automatic Rescue Device (ARD)

Automatic Levelling

Card / Bio-Matrix

Global System for Mobile Communication (GSM)

Remote Monitoring Function

An emergency power to bring the lift to nearest adjacent landing during building power failure

Returning of lift car to the nearest landing for evacuation upon the detection of earthquake.

Advance lift access control by means of fingerprint or access card system.

Automatic GSM notification system in the event of breakdown or main building power failure.

Real time elevator monitoring system via 3G network.

Supervisory Panel On site monitoring of lift (s) operation status.

Security Code Call Enabling person with password to access specific floors.

Voice Synthesizer Lift car annoucement system.

Parking Mode

Non-Service Floor

Lift goes into energy conservation mode by means of a key switch to disable all Hall Call Panels.

Lift will not serve this pre-determined floor.

Priority Floor Auto levelling and re-levelling, ensuring level between car and landing door sill.

VIP Priority Service

VIP calling service at specific floor by means of access control system.

Door Infra-Red Sensor Multi-beam safety curtain sensor fitted on the lift car door.

Infrared Curtain

2 In 1 Safety Door Edge

Extended Door Hold

Car Arrival Chime

Hall Arrival Chime

Hall Arrival Lantern

Fire Return Service

Fireman Operation

Group Control System

Selective Collective Automatic Operation

Automatic Floor Support

Overall Independent Lift Standby Function

Optical sensor detecting obstacles along the doorway and prevent elevator door from closing.

An enhanced door safety feature that combines both infra-red and mechanical safety edge.

Extend door opening time for greater convenience with additional button on Car Operating Panel.

Lift car arrival chime upon arrival of desired floor.

Audible chime upon the arrival of lift at the particular floor.

Arrival lantern installed at lobby will lit up upon arrival of lift.

Return of lift to designated level for evacuation in the event that the fire alram is activated.

Elevator return to designated floor with door remained open for fireman operation.

Capable of controlling up to 8 elevators that manage traffic flow efficiently hence reducing waiting time during peak hours.

Answering of relevant landing call (s) in the direction of travel.

Assigning of alternate car to serve call that is not answered by the primarily assigned car in time.

Elevator cars distributed to standby at different floors that effectively reduces waiting time.

Peak Service Designated floor will be given priority during peak hours.

30
Optional
DM-83B01 E-Feng Machinery Engineering Co., Ltd. www.e-f.com.tw TEL:+886-3-498-6000 No.198-215. 2, Zhong ai Rd., Guanyin Dist., Taoyuan City 328, Taiwan MANUFACTURED BY E-FENG