Bramhall: Extensions, loft conversion, refurbishment

Page 1

59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson SITE PLAN & location plan EXISTING DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS
MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 1 1 N BRIDGE LANE HEADLANDS ROAD 1 61 29 23 1 4 52 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D S01 S01 01-E E02 03-E E04 RECEPTION 1 RECEPTION 2 DINING HALL UTILITY WC GYM 1 location plan 1:1250 2 EXISTING SITE PLAN 1:100 REAR GARDEN APPROX SITE BOUNDARY EDGED RED PUBLIC FOOTPATH APPROXIMATELY12M BELOW FLOOR GARAGE FLOOR LEVEL DRIVEWAY ACCESS
SCALE @ A3 1 1250, 1:100
CONTRACTOR
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson Ground Floor EXISTING DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 1 2 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D -1.40 -0.40 S01 S01 E-01 E02 E-03 E04 RECEPTION 1 RECEPTION 2 DINING HALL UTILITY WC GYM YELLOW SHADED CROSSHATCH ELEMENTS TO BE REMOVED / MODIFIED TO FACILITATE PROPOSED LAYOUT REFER TO SENGR FOR SEQUENCING & TEMPORARY SUPPORTS IF REQUIRED REPLACE IC WITH MANHOLE REDUNDANT DRAIN TO BE REMOVED
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson 1ST Floor EXISTING DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 1 3 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D S01 S01 E-01 E02 E-03 E04 BEDROOM 1 BEDROOM 2 BEDROOM 3 LANDING BEDROOM 4 SHOWER / WC ENSUITE ENSUITE YELLOW SHADED CROSSHATCH ELEMENTS TO BE REMOVED / MODIFIED TO FACILITATE PROPOSED LAYOUT REFER TO SENGR FOR SEQUENCING & TEMPORARY SUPPORTS IF REQUIRED
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson LOFT ROOF PLAN EXISTING DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE
HAVE
FOR PLANNING
OR BUILDING
PURPOSES
OF WORKS ON
ALL THAT IS
TO
SUBMISSION OF A
TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 1 4 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D S01 S01 E-01 E02 E-03 E04 REMOVE STACK
DRAWINGS
BEEN PRODUCED
&
REGULATIONS
ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE
SITE AND INCORPORATE
REQUIRED
ENABLE
BONAFIDE
SCALE @ A3 1 100 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson Elevations EXISTING DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 1 5 A A B B C C E E F F D D G G ±0 000 0 GF-Ground Floor ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor +2 606 1 01-First Floor 8 8 7 7 6 6 4 4 2 2 1 1 5 5 3 3 ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor F F E E C C B B A A G G D D 1 1 2 2 4 4 6 6 7 7 8 8 3 3 5 5 ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor 1 NORTH Elevation 1:100 4 EAST Elevation 1:100 3 SOUTH Elevation 1:100 2 WEST Elevation 1:100 A REV A 211031 PLANNING AMENDMENT
59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson SITE PLAN & location plan PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS
MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 1 N BRIDGE LANE HEADLANDS ROAD 1 61 29 23 1 4 52 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D 1,530 9,134 1,264 933 BEAM 11 BEAM 02 BEAM 00 BEAM 10 BEAM 05 BEAM 07 BEAM 03 BEAM 04 BEAM 08 BEAM 06 BEAM 09 COL 01 COL 02 BEAM 01 440 440 440 340 + 00.00 -1.40 -0.40 S01 S01 01-E E02 03-E E04 RECEPTION 1 HALL KITCHEN UTILITY WC GYM OPEN PLAN ROOMFAMILY 1 location plan 1:1250 2 EXISTING SITE PLAN 1:100 DRIVEWAY REAR GARDEN ACCESS APPROX SITE BOUNDARY EDGED RED PUBLIC FOOTPATH APPROXIMATELY12M BELOW FLOOR GARAGE FLOOR LEVEL
SCALE @ A3 1 1250, 1:100
CONTRACTOR
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson Ground Floor PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 2 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D 1,530 9,134 1,264 933 BEAM 11 BEAM 02 BEAM 00 BEAM 10 BEAM 05 BEAM 07 BEAM 03 BEAM 04 BEAM 08 BEAM 06 BEAM 09 COL 01 COL 02 BEAM 01 440 440 440 340 + 00.00 -1.40 -0.40 S01 S01 E-01 E02 E-03 E04 RECEPTION 1 HALL KITCHEN UTILITY WC GYM OPEN PLAN FAMILY ROOM DATUM APPROX PATH LEVELS NOTE SIGNIFICANT DIFFERENCE IN GROUND PATH LEVELS KITCHEN UTILITY LAYOUT BY OTHERS FORM MANHOLE ON EXISTING DRAIN NEW DRAIN CONNECTION << AG DRAINAGE FIXED TO BRICKWORK @ 1 40 FALL << BG DRAINAGE @ 1 40 FALL RODDING ACCESS RODDING ACCESS SVP SVP EXISTING SHALLOW DRAIN INSPECTION RECOMMENDED REFER TO SENGR FOR ALL STRUCTURALLY RELATED ISSUES DESIGN DETAIL / CALCULATIONS CAVITIES MADE CONTINUOUS WITH EXISTING INSULATED SOFFIT ACOUSTIC STUDDING ACOUSTIC STUDDING PROVIDE 30MIN FR TO ALL STEELWORK SUPPORTING FLOORS PROVIDE MAINS WIRED INTERLINKED SMOKE DETECTION TO HALL AND LANDING LEVELS SD PAVING DECKING STEPS FLUSH TRESHOLD TO BIFOLD DOORS BUILD UP EXISTING DOORWAY REFR TO CLIENT APPOINTED SPECIALIST FOR ALL FIXTURES FITTINGS & FINISHES REFER TO CLIENT APPOINTED MEP CONSULTANT FOR ALL MODIFICATIONS TO BUILDING SERVICES AND FOR ALL ANY NEW INSTALLATIONS
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson 1ST Floor PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 3 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D S01 S01 E-01 E02 E-03 E04 1,530 4,055 4,884 1,264 BEAM 14 BEAM 13 BEAM 12 BEAM 19 BEAM 18 BEAM 17 BEAM 16 BEAM 15 BEAM 20 BEDROOM 1 BEDROOM 2 BEDROOM 3 LANDING BEDROOM 4 SHOWER / WC ENSUITE ENSUITE POST 01 POST 02 SVP SVP PROVIDE MAINS WIRED INTERLINKED SMOKE DETECTION TO HALL AND LANDING LEVELS SD PROVIDE 30MIN FR TO ALL STEELWORK SUPPORTING FLOORS CAVITIES MADE CONTINUOUS WITH EXISTING CAVITIES MADE CONTINUOUS WITH EXISTING CAVITIES MADE CONTINUOUS WITH EXISTING CAVITIES MADE CONTINUOUS WITH EXISTING VELUX INTEGRA GGL UK04 ROOFLIGHTS DESIGN FOR NEW STAIRS BY SPECIALIST, SUBJECT TO SITE MEASUREMENTS NEW DOORWAY MAKE GOOD TO FLAT ROOF VELUX GGL UK04 ROOFLIGHT WASTE PLUMBING TO SUIT NEW LAYOUT 110MM PVCU AG DRAINAGE CONCEALED IN LEAN-TO BULKHEAD FITTED WITH AAV & RODDING ACCESS AT BOTH ENDS REFR TO CLIENT APPOINTED SPECIALIST FOR ALL FIXTURES FITTINGS & FINISHES REFER TO CLIENT APPOINTED MEP CONSULTANT FOR ALL MODIFICATIONS TO BUILDING SERVICES AND FOR ALL ANY NEW INSTALLATIONS
SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson LOFT ROOF PLAN PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS
MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 4 A A B B C C 1 1 2 2 4 4 E E H F F 6 6 7 7 8 8 3 3 5 5 G G D D S01 S01 E-01 E02 E-03 E04 3,547 100 3,000 2,270 100 2350 4,167 BEAM 21 BEDROOM 5 OFFICE STORAGE LANDING POST 01 POST 02 SPECIAL LINTOL PROVIDE MAINS WIRED INTERLINKED SMOKE DETECTION TO HALL AND LANDING LEVELS SD FD30 FD 30 ACOUSTIC STUDDING VELUX GGL SK06 SAFETY GLAZING TO PEDIMENT WINDOW IN CRITICAL LOCATIONS FD30 REFR TO CLIENT APPOINTED SPECIALIST FOR ALL FIXTURES FITTINGS & FINISHES REFER TO CLIENT APPOINTED MEP CONSULTANT FOR ALL MODIFICATIONS TO BUILDING SERVICES AND FOR ALL ANY NEW INSTALLATIONS
CONTRACTOR
SCALE @ A3 1 100 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson Elevations PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 5 A A B B C C E E F F D D G G ±0 000 0 GF-Ground Floor ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor +2 606 1 01-First Floor 8 8 7 7 6 6 4 4 2 2 1 1 5 5 3 3 ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor F F E E C C B B A A G G D D 1 1 2 2 4 4 6 6 7 7 8 8 3 3 5 5 ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor 1 NORTH Elevation 1:100 4 EAST Elevation 1:100 3 SOUTH Elevation 1:100 2 WEST Elevation 1:100 PROPOSED REAR DORMER PROPOSED 1ST FLOOR REAR EXTENSION PROPOSED 1ST FLOOR SIDE EXTENSION PROPOSED SINGLE STOREY REAR EXTENSION PROPOSED PEDIMENT FEATURE PROPOSED CANOPY EXTERNAL MATERIALS USED IN EXTENSIONS TO MATCH MAIN DWELLING A REV A 211031 PLANNING AMENDMENT 4 X DECORATIVE STRING COURSES GALLOWS BRACKET SUPPORT TO CANOPY RESIN ANCHORED TO BRICKWORK

GROUND

WALL PART FILLED

FOUNDATIONS 600Wx300D

Refer

Contractor to check for presence of all below ground services and record location on a plan, prior to general excavations, to establish hazard and associated risk levels and any required safety measures that may need to be implemented

Drainage layout indicated as part of the proposals is generic and assumed only and will need to be determined between the contractor & BCO once the existing drainage provisions have been exposed Negotiation with United Utilities may be required if drainage clashes with proposed extension In some cases, this may affect the practicality and buildability of the proposal

WINDOWS

PVCu with 28mm DG units filled with argon and low E glass Windows configured to function as AMOE due to open plan hallway Frames to overlap wall insulation by 30mm min Frames to habitable rooms to include 8000mm2 trickle vents & to be fully draught stripped All glazing in critical locations to comply with statutory safety requirements & Approved Documents

Refer to structural engineer for all structural queries clarification calculations & stability checks

Air Barrier Continuity: Set wall plate on a continuous mortar bed, fix ceiling boards first & seal all gaps between ceiling & masonry wall with either plaster, adhesive or flexible sealant Plasterboard on dabs to have continuous ribbon of adhesive around openings along the top & bottom of walls and at internal & external corners

All penetrations through air barrier to be sealed using an approved flexible sealant Seal gap between wall & floor air barrier & between skirting & floor with flexible sealant

Mortar joints around built-in joists to be recessed or struck & carefully pointed with with flexible sealant Seal between the wall air barrier and blockwork above & below the floor assembly Apply flexible sealant to all interfaces between the internal air barrier and the window & door frame members All window opening lights external doors & loft access panels to be fitted with draught stripping

General

Where

Refer

Light

All gas & electrical work to be undertaken by a suitably qualified person and tested certified in

SCALE @ A3 1 50 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson S-01 Section PROPOSED DWG No 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev 18 07 2022 SCALEBAR cm): 50 2cm m 100 cm m 200 cm m 1 500 cm m 0 2 3 DATE ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES NOTE WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY AS MAY BE REQUIRED FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED DO NOT SCALE FROM PLAN IF IN DOUBT ASK! DWG TITLE SITE LOCATION: CLIENT STATUS BUILDING REGS ISSUE A 03 2 6 1 1 2 2 4 4 6 6 7 7 ±0 000 0 GF-Ground Floor +2 606 1 01-First Floor 1000 MIN 400 APPROX 2,100 2400 1900 MIN 900 900 1900 MIN 900 1800 MIN 900 32° COLD FLAT ROOF: INSULATION @ JOIST LEVEL U Value 0 14W m2K Single ply EPDM roof membrane fully adhered to 18mm marine ply laid to 1:80 fall firrings & counter battens for cross ventilation / 150x50 nominal C16 roof joists @ 600mm cts / 100mm PIR between joists with 50mm air gap above 50mm PIR below rafters joints foil taped to form complete VCL 50x25mm battens & counter battens 12 5mm plasterboard & skim to underside / 25mm continuous eaves vent to all sides COLD PITCHED ROOF INSULATION @ RAFTER LEVEL U Value 0 14W m2K Interlocking concrete tiles to match existing treated 50x25mm battens breathable underlay timber rafters to sengr detail 100mm PIR between rafters with 50mm air gap above 50mm PIR below rafters joints foil taped to form complete VCL / 50x25mm battens & counter battens / 12 5mm plasterboard & skim to underside 25mm continuous eaves vent trays & ventilated ridge dry verge detail CAVITY
U Value 0 17W m2K Clay facings to match existing 25mm clear cavity 75mm PIR cavity insulation / 100mm aerated block inner leaf subject to SEngr spec) 12 5mm plasterboards on dot & dab adhesive wall ties & retaing discs @ 750Hx450V cts DPC 150mm min above ground level DPC on inner leaf to be lap bonded to DPM Insulated cavity closers to reveals & cills / insulated cavity
wall lintols new cavities made continuos with existing
min proprietary self levelling floor screed suitable for UFH system
/ VCL 100mm PIR floor insulation / 25mm PIR perimeter
DPM
barrier
may be required)
grade floor slab
sand blinded consolidated
FLOOR: 0 7P A ratio U Value 0 15W m2K 40mm
pipework
upstand insulation
GAS/RADON
(as
150mm C30
150mm
hardcore
min conc strips taken down below invert level of adjacent
min depth or until firm strata is
drainage to 1 0m
reached subject to engineer details modification if required] Drains to be protected and isolated where below extension and passing through footings to the BCO satisfaction
to client appointed structural engineer for all structurally related detail
Minimum standard of construction to comply with Accredited details & Building Regulations
necessary provide mechanical ventilation ducted to external air from bathroom wc & utility areas at 15 /sec 30L/sec from hob extractor
to Structural engineer for all structural works where deemed necessary
fittings to be the type that will only accept low energy bulbs Refer to electrical contractor for full details in compliance with L2B
accordance with statutory requirements All disturbed surfaces to be made good Site to remain clean tidy & safe throughout the duration of the works all debris to be removed from site by the contractor and disposed of appropriately Contractor to carry appropriate insurance for all risks and implement adequate site safety security & weather protection throughout the contract period REFER TO MAIN CONTRACTOR FOR ALL BUILDING SERVICES DESIGN MODIFICATIONS & ADDITIONS SUBJECT TO CLIENT PRIOR APPROVAL NEWEL POST SUPPORT TO 2ND FLOOR LANDING TRIMMERS REFER TO SENGR FLOOR TO FLOOR DIMENSION TO BE CHECKED PRIOR TO FABRICATION NEW STAIRS 13 RISERS @ 211MM WITH GOINGS @ 235MM = 42O PITCH 50MM MIN GOINGS ON WINDERS MIN HEADROOM 2 0M ON MAIN STAIRS, 1 9M ON NEW STAIR CENTRE-LINE / 1 8M AT SIDES HANDRAILS 900MM ABOVE PITCHLINE & LANDINGS GAPS BETWEEN SPINDLES OR INFILL PANELS NMT 99MM SPECIALIST COMBINED INSULATED ARCHED LINTOL TO PEDIMENT WINDOW 4 X DECORATIVE BRICK STRING COURSES NEW PLAIN CLAY TILED CANOPY VENTILATED COLD PITCHED ROOF VENTILATED COLD FLAT ROOF REFER TO SENGR FOR JOIST ARRANGEMENT SIZES ETC SOUND INSULATED SOILPIPE IN BULKHEAD WITH RODDING ACCESS @ CHANGE IN DIRECTION AG DRAINAGE FIXED TO BRICKWORK @ 1 40 FALL ENSURE CONTINUOUS SUB-FLOOR VENTILATION IS MAINTAINED FIT STEELWORK AS HIGH AS POSSIBLE TO FLOOR JOIST BEARING VENTILATED COLD PITCHED ROOF ASSUMED FOOTING REAR DORMER WALL BUILT OFF INNER LEAF / STEELWORK TELESCOPIC VENTS VENTS REFR TO CLIENT APPOINTED SPECIALIST FOR ALL FIXTURES FITTINGS & FINISHES REFER TO CLIENT APPOINTED MEP CONSULTANT FOR ALL MODIFICATIONS TO BUILDING SERVICES AND FOR ALL ANY NEW INSTALLATIONS

GENERATED

NOTE: WHERE PLANS

PHOTOS

MUST CHECK FOR ACCURACY &

PRIOR TO COMMENCEMENT,

BE

IMMEDIATELY THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED

THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY, AS MAY BE REQUIRED; FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS

CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER

SCALE @ A3: 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson VISUALS PROPOSED DWG No: 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev: 18/07/2022 SCALEBAR cm): 1 50 2cm=1m 1 100 cm= m 1 200 1cm= m 1 500 1cm=5m 1 0 2 4 5 6 DATE: ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT: 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING: CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS, ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES
ARE
FROM DIMENSIONS AND
PROVIDED BY CLIENT THE CONTRACTOR
WORKABILITY
ANY DISCREPANCY MUST
REPORTED
CLIENT
CONTRACTOR
FACILITATING
SPECIALIST
MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN
TO INCLUDE FOR ANY BWIC WITH
SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED
BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE
DWG TITLE SITE LOCATION: CLIENT: STATUS: BUILDING REGS ISSUE A 03 2 7
CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION APPROX DIMS INDICATED: DO NOT SCALE FROM PLAN IF IN DOUBT ASK!

THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED

THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY, AS MAY BE REQUIRED; FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS

CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC

CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE

CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED

ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE

ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION

APPROX DIMS INDICATED: DO NOT SCALE FROM PLAN IF IN

SCALE @ A3: 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson VISUALS PROPOSED DWG No: 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev: 18/07/2022 SCALEBAR cm): 1 50 2cm=1m 1 100 cm= m 1 200 1cm= m 1 500 1cm=5m 1 0 2 4 5 6 DATE: ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT: 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING: CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS, ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES
NOTE: WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT, ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY
DWG TITLE SITE LOCATION: CLIENT: STATUS: BUILDING REGS ISSUE A 03 2 8
DOUBT ASK!

THIS INFORMATION IS NOT TRANSFERRABLE AND GRANTING LICENSE FOR USE OF THIS INFORMATION BY ANY OTHER PARTY IS DONE SO ON THE CONDITIONAL BASIS THAT THE LICENSEE CARRIES OUT THEIR OWN DIMENSIONAL CHECKS FOR ACCURACY OTHERWISE THE USE OF THIS INFORMATION IS PROHIBITTED

THESE DRAWINGS HAVE BEEN PRODUCED FOR PLANNING & OR BUILDING REGULATIONS PURPOSES ONLY, AS MAY BE REQUIRED; FURTHER AMENDMENT MAY BE REQUIRED TO ACHIEVE COMPLIANCE WITH STATUTORY REQUIREMENTS

CONTRACTOR MUST ASSESS ENTIRE SCOPE OF WORKS ON SITE AND INCORPORATE ALL THAT IS REQUIRED TO ENABLE SUBMISSION OF A BONAFIDE TENDER CLIENT MUST SPECIFY FINISHES AND WHETHER ANY EXTERNAL SUBCONTRACTORS ARE TO BE USED MAIN CONTRACTOR TO INCLUDE FOR ANY BWIC WITH FACILITATING SUBCONTRACTORS PACKAGES EG CLIENT APPOINTED SPECIALIST BATHROOM KITCHEN DESIGN & INSTALLATIONS ETC

CONTRACTOR MUST LIAISE WITH SENGR IF GUIDANCE IS REQUIRED FOR TEMPORARY SUPPORTS & DEMOLITION SEQUENCE

CONTRACTOR TO TRACE LOCATE ALL BURIED SERVICES PRIOR TO WORK COMMENCEMENT & TO LIAISE WITH STATUTORYAUTHORITIES FOR ANY WORKS TO SERVICES THAT MAY BE REQUIRED

ELEMENTS TO BE REMOVED OR MODIFIED IN SUCH A MANNER AS TO FACILITATE THE PROPOSED LAYOUT & DESIRED APPEARANCE

ALL DISTURBED SURFACES TO BE MADE GOOD INCLUDING DECORATION

APPROX DIMS INDICATED: DO NOT SCALE FROM PLAN IF IN DOUBT ASK!

SCALE @ A3: 59 BRIDGE LANE BRAMHALL SK7 3AL Leila Fadiora-Johnson VISUALS PROPOSED DWG No: 07931906057 : http://www shielsdesign com * studio@shielsdesign com © SHIELS DESIGN LTD All rights reserved Rev: 18/07/2022 SCALEBAR cm): 1 50 2cm=1m 1 100 cm= m 1 200 1cm= m 1 500 1cm=5m 1 0 2 4 5 6 DATE: ALL DESIGN WORK IS SUBJECT TO STATUTORY APPROVALS AND MAY REQUIRE AMENDMENT: 3D VISUALS ARE FOR ILLUSTRATION PURPOSE ONLY INCLUDING ANY ASSOCIATED BIMX MODELLING: CONTRACTOR TO CHECK ALL DIMENSIONS AND DETAILS, ON SITE PRIOR SUBMITTING TENDER AND PLACING ORDERS FOR MATERIALS OR FOR FABRICATION PURPOSES
NOTE: WHERE PLANS ARE GENERATED FROM DIMENSIONS AND PHOTOS PROVIDED BY CLIENT THE CONTRACTOR MUST CHECK FOR ACCURACY & WORKABILITY PRIOR TO COMMENCEMENT, ANY DISCREPANCY MUST BE REPORTED IMMEDIATELY
DWG TITLE SITE LOCATION: CLIENT: STATUS: BUILDING REGS ISSUE A 03 2 9