Sebnem Tuncel MacDonald 2006 - 2010 Historic Projects

Page 95

F3

PLAN

Entrance F1 The hole on the ceiling to be reshaped as ellipse

1/5

Do not scale dimensions off drawings. Use written or calculated dimensions. The contractor i s responsible for checking all dimensions before ordering or starting work.

New frame Match / continue existing entrance door frame

This drawing has been produced for the client for the p r o j e c t o n t h e s i t e s h o w n. I t w a s p r e p a r e d f o r a p u r p o s e agreed with the client and will have a commensurate d e g r e e o f a c c u r a c y. I t i s n o t a r e c o r d "as built". T h i s d r a w i n g is not intended for use by any other person or for any other p u r p o s e t h a n t h a t s p e c i f i e d h e r e. Inkpen Downie Architecture &Design accept no liability whatsoever if this drawing is used by any other person or for a n y o t h e r p u r p o s e.

F1

Existing skylight to be moved 200mm.

Mrs Johnson's Study

852

NOTES

Cloakroom

1294

EXISTING DOOR FRAME

NEW WINDOW

New fanlight over street door

1/5

130

SECTION

Up

New lintel to structural engineers details New frame Match with existing entrance door frame

240

F3

1/20

45

60

ENTRANCE PLAN

F2 64

F2

New timber cill Existing door frame

Existing roof structure

Existing skylight to be moved 200mm.

Replace old brick coping with new stone coping all the way round parapet

Balcony

Renew roof cover

Existing skylight to be moved 200mm.

+14.74

Existing concrete steps Take down and rebuild existing brick parapet Use existing bricks in good condition 13.83

+13.83

+13.83 B A

05/03/08 New sash window to GW01 13/08/07 Change on door & window frame details

Rev Date

ST ST

Revision

Drawn By

The hole on the ceiling to be reshaped as ellipse

The hole on the ceiling to be reshaped as ellipse

Inkpen Downie Architecture & Design Ltd

New fanlight over street door

2 Balkerne House

Balkerne Passage

Tel 01206 577 244 arch@inkpendownie.co.uk

Colchester

CO1 1PA

Fax 01206 563 377 www.inkpendownie.co.uk

3100

3090

3050

3100

Drawing Status

CONSTRUCTION Project

Entrance Entrance

2200

Regency House

Mrs Johnson's Study

Client

Partitions removed

Cloakroom

Partitions removed

Cad File

Mac 7 - 708 +10.50

+10.50

Scale

Drawn By / D a t e

1: 20 50 / 1:5

ST/12.06.2007 BD/

Checked By / Date

Title

ENTRANCE GROUND FLOOR DOORPLAN & WINDOW DETAIL D r a w i n g N o.

A/708/C/21 A/708/C/02

SECTION F1-F1

1/20

ELEVATION F2-F2

1/20

SECTION F3-F3

1/20

R e v N o.

B

Copyright reserved by Inkpen Downie Architecture & Design. This drawing shall not be reproduced or used without prior permission of the partnership.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.