Zero Impact Building|Church Transformation

Page 1

THE YOUTH CENTER (The Flow) Zero Impact Building Next Economy KULeuven Architecture Departmen-Gent 2016

Esin Ozkiliรง, Nadia Raviola, Sadaf Arsalani, Sadaf Khalilzare


PROJECT SUMMERY BASIC DATA

NATURE

function of the building: Youth Center how many users: 300 total m2 : 3711.4 m2 total m3 : 28759.95 m3

The network suggested by the design is hold by a green line of trees and greenery which will connect different spots with adding value to the city and neighborhood as well.

CONTEXT

ECONOMY

Address: Wondelgemstraat Existing situation: Sint-Jozef Church

The design approach is to guide the youth of new comers and current residents of the neighborhood with an education which can help them with more handy stuff such as arts and crafts, and will bring new possibilities for the people who don’t want to gain an academic degree to find suitable jobs in future.

ENERGY gains and demands / incl. Heating and Ventilation ) heating = 54.9 kWh/m2.yr total energy demand = 50.9 kWh/m2.yr total energy production = 57 kWh/m2.yr energy production = 21.4 kWh/m2.yr by Pv Panels 3.76 kWh/m2.yr by Pedal-A-Watt 27.5 kWh/m2.yr by Wind Turbines 4.4 kWh/m2.yr by Solar Collectors MATERIALS which and why the main sustainable materials + m3 or m2 which CO2 positive materials which labels WATER total water demand: 624000 l/yr Treatment water pond Natural infiltration of rain water MOBILITY New Bike access for the neighborhood was suggested by this design an access with green buffer which is connecting different churches with a bike path and a green line

Zero Impact Building

KULeuven . 2016


The Flow Esin Ozkiliรง Turkey Interested in innovative architecture responsible for SMART BUILDING Nadia Raviola Italy Full of initiative, determined and a lover of beautiful things responsible for ZERO ENERGY + ZERO IMPACT Sadaf Arsalani Iran Optimistic and a big fan of simplicity responsible for the CALCULATIONS + TEAMMANAGER responsible for SUSTAINABLE CONCEPT Sadaf KhalilZare Iran Interested in universal design responsible for LOW TECHNICS Zero Impact Building

KULeuven . 2016


THE YOUTH CENTER The church of Sint Josef is located at the core of the neighborhood of Rabot. Rabot is a triangular neighborhood northeast to the center, about 15 minutes walk from it. It is quite well connected by public transport to the other parts of the city. Here, a vast multicultural community inhabits the place and sees as main gathering places the front of the church and the main street, Woldenghemstraat. At any time of the day, the place is very active and you can see the younger ones hanging out, the adults shopping and the older gathering. There is a strong sense of community among some of the multicultural groups, but not all of them are interacting. The Belgian community for example does not mix with the other cultures a lot, as well as others. Moreover there is a current state of chaos on the main street, mainly caused by unmanaged traffic and pedestrian flows. The aim of the project is therefore to bring the inhabitants of Rabot altogether in a place they can identify with and that can be a reference for them, starting from the youth, which we see as the future of the neighborhood and as potential mediators among adults. As the Sint Josef church will be deconsecrated in 2017, this would be an excellent place to take over for a youth center, but also a green energy producing gym, that will host everyone who is willing to work out and some quiet areas to study together with a cafeteria where the community is also welcome.

Zero Impact Building

KULeuven . 2016


The Network

• Connecting Rabot with the rest of the city • Abondened churches in Gent • The access network connecting the churches • Different programs in different neighborhoods • More biodiversity by adding and connecting green areas

Zero Impact Building

KULeuven . 2016


Rabot

Churches

Parks

Restaurant

shop

Mosque

school

Microclimate studies STEREGRAPHIC PROJECTION SUNPATH

SITUATION AT LOCATION: ON JUNE 21 / CURRENT / DECEMBER 21

Zero Impact Building

WIND DIRECTION DISTRIBUTION IN (%)

SUMMER AND WINTER SHADOWS

KULeuven . 2016


Context

bike route

tram line 1 Tram line line 1 tram 1

routetram line 1sail route tram bike line 4 tram line 1 Tram line bike 2line route Carcar routroute Bike routroute line 4 bike tram 4 tram line 1sail route tram

tramaline sail route tram line 4 • Defining new4urban green tissue car route • Bringing more daily travelers to the neighborhood car route car route

Zero Impact Building

bike route Sail routroute sail

Bus stop

car route sail route

The street is proposed to be one way to avoid the traffic and make the transportation more fluent.

KULeuven . 2016


Concepts

Zero Impact Building

KULeuven . 2016


Sustainability Concepts

Accessibility Solar Collectors

5 closed circle of the Flows

Wind Turbines

Electrical Bike parking

• Energy

Solar Panels Solar collectors Wind Turbines Geothermal Heat Pumps Energy Production: 57 kwh/m2 .yr Consumption: 47.7 kwh/m2 .yr Energy production PV Panel: 21.4 kwh/m2 .yr GYM: 3.76 kwh/m2 .yr Wind Turbine: 27.5 kwh/m2 .yr Solar Collectors: 4.4 kwh/m2 .yr

Greenary

Bus Station

Car parking

• Material

All the materials we used are either recycable, recycled or reused

Natural Ventilation Solar Panels Recycled or Recycable Materials

• Light

Natural Light (Bond Reflection) Lights with high energy efficiency

LED

Wind Turbines

• Ventilation

Natural Ventilation (chimney, stack Effect+ Bernoulis principle)

• Water

Pond

Pedal-A-Watt Bike

Eco-Gym

Solar Collectors

Rain Water storage Grey water treatment (pond) Natural infiltration (pond) Total water demand: 624000 l/yr Zero Impact Building

KULeuven . 2016


Compartments and Zoning

Workshop

Ground Floor

Study room

Storage

Detailed Info

• Workshop temp: 18o c area: 163.7 m2 height: 3.85 m users: 46

• Study room temp: 21o c area: 114.4 m2 height: 3.85 m users: 24

• Storage

Occasional performance stage

temp: no need to be controled area: 40.2 m2 height: 6.67 m users: 0

• Storage

temp: no need to be controled area: 193.6 m2 height:19.19 m users: Max 100

Impermanent Office Toilettes

• Toilettes

temp: no need to be controled area: 40.2 m2 height: 6.67 m users: no permenent user number of toilettes: 7

• Impermanent Office

temp: no need to be controled area: height: users: 1 Total number of permanent users: 70 Zero Impact Building

Fire safety regulation regarding the escape routs are all considered according to the compartments and their capacity KULeuven . 2016


FirstFloor Detailed Info

• Workshop temp: 18o c area: 79.3 m2 height: 4.4 m users: 35

Organ

Workshop

Compartments and Zoning

Study room

Study room

• Study room temp: 21o c area: 206.2 m2 height: 4.4 m users: 80

• Balcony

Balcony

• Cafeteria

Cafeteria

temp: no need to be controled area: 158.8 m2 height:users: 0

temp: no need to be controled area: 128.5 m2 height:3.00 m users: 45 Total number of permanent users: 160

Zero Impact Building

Fire safety regulation regarding the escape routs are all considered according to the compartments and their capacity KULeuven . 2016


Compartments and Zoning

Treadmile

Basement

Bike

Storage

Detailed Info

• Gym

temp: no need to be controled area: 1317.5 m2 height: 2.2 m users: 140

• Storage

temp: no need to be controled area: 100.5 m2 height: 2.2 m users: 80

Pilates

• Mechanical room

temp: no need to be controled area: 156.1 m2 height:users: 0

Yoga Total number of permanent users: 140

Showers And Changing Rooms

Zero Impact Building

Fire safety regulation regarding the escape routs are all considered according to the compartments and their capacity KULeuven . 2016


Planning (Basement)

Storage

Technic room

Zero Impact Building

Basement sc 1:250 KULeuven . 2016


Planning (First Floor)

Zero Impact Building

First Floor sc 1:250 KULeuven . 2016


Planning (Ground ) Crypt Access Slope 7%

Wheelchair Access

Storage

Slope 7%

Entrance

Slope 10%

Slope 12%

Eco GYM Entrance

Zero Impact Building

Ground Floor sc 1:250 KULeuven . 2016


Interior Design

Zero Impact Building

KULeuven . 2016


Planning (Roof )

Zero Impact Building

Roof Plan sc 1:250 KULeuven . 2016


Technical Room

Zero Impact Building

Section sc 1:200

KULeuven . 2016


Structural scheme Light Steel Structure

Zero Impact Building

KULeuven . 2016


Zero Impact Building

KULeuven . 2016


Thermal Behavior of The Building

Zero Impact Building

KULeuven . 2016


Heating System

First Floor

Zero Impact Building

KULeuven . 2016


Heating System

Crypt Access Slope 7%

Storage

Slope 7%

Entrance

Slope 10%

Ground Floor

Zero Impact Building

KULeuven . 2016


Heating Section

Zero Impact Building

KULeuven . 2016


Heating System

Storage

Technic room

Basement

Zero Impact Building

KULeuven . 2016


Mechanical Ventilation

Storage

Technic room

Basement

Crypt Access Slope 7%

Storage

Slope 7%

Entrance

Slope 10%

Ground Floor(only Bathrooms) The rest has natural ventilation

First Floor


Sewage system Rain Water Pipe: Using the Existing Pipes Existing Rain water pipes

In case of over will the rain water will be pumped to pond for natural infiltration

Septische Watertank

City

Sand Filter

20 pipes of 109mm diameter are needed to carry out the rain water from the roofs The existing pipes are bigger than 109mm => we do not need to add more pipe Rain water tank is 1000 L And in the case of overfill the water will go to the pond for natural absorption

Water Heater

Air ventilator

Technic room In case of over flow pump to the pond Septische Watertank 10000 L

pump

Septische Watertank 10000 L

Basement Mechanical room and Gym showers scale 1:20

Slope 10%

Ground Floor (Bathrooms) Enhancing

Natural

First Floor ( Cafeteria)


Ventilation Section

Zero Impact Building

KULeuven . 2016


Ventilation (Mechanical-Natural) Ventilation (Mechanical-Natural Natural Ventilation ) Due to almost 15 meter height difference in highest part of our intervention with church roof stack effect can help natural air Natural Ventilation circulaton and warm go up for supply air we put the can entrance duct in wind direction also Due to almost 15 meter height difference in highest part of air ourwill intervention with churchofroof stack effect help natural airthe circulaton and warmand air will goby upBernoulis for supply effect of air we put low pressure of extracted air ,will make a suction perpendecular and it will bring air inside. the entrance duct in the wind direction and also by Bernoulis effect low pressure of extracted air ,will make a suction perpendecular and it will bring air inside. Mechanicalground basement (allfirst seasons) groundwinter) and first floor(only winter) Mechanical basement (all seasons) and floor(only

Bernouliventilation principle is combined with heating system by Geo-Thermal energy(The pipes go deep to ponds). The Mechanical The Mechanical ventilation is combined with heating system by Geo-Thermal energy(The pipes go deep to ponds).

CIRCULAR DUCT FAN M3 500 KD

Air Flow:2300 - 50 l/s High efficiency – low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

Zero Impact Building

KULeuven . 2016


Materials (Life Cycle Assesment) Structure

Zero Impact Building

KULeuven . 2016


Materials (Life Cycle Assesment) Opaque material

Zero Impact Building

KULeuven . 2016


Materials (Life Cycle Assesment) Glass

Zero Impact Building

KULeuven . 2016


Materials (Life Cycle Assesment) Heat insulation

Zero Impact Building

KULeuven . 2016



Energy production

The materails have been chosen according to the consideration of CO2 emission , life cycle of material , sustainability and cost . As a result of LCA mainly Belgian brands were chosen to be used in the design .





Lightening(Simulation with Dialux)

company:ETAP LED LP,RAL9210A Diffuser 2500lm,power consumption:30w white

changing room-wc

company:ETAP LED LP,RAL9210A Company:ETAP LEDDiffuser HP,EER 2500lm,power consumption:30w Surface mounted 2500lm,power consumption:19.2w white

Danceroom3

changing room-wc

white

Danceroom3

Studyroom GYM

changing room-wc

Danceroom3 cafe

Storage

Company:ETAP Company:ETAP LED HP,EER Studyroom LED,RAL9003 Surface mounted 2500lm,power consumption:19.2w Downlight 1650lm,power consumption:14.9w Terrace whitewhite

GYM WC

Danceroom1

Studyroom GYM

cafe

atelier 4

Company:ETAP LEDCompany:ETAP LP,Surface mounted Diffuser 1550lm,power concumtion=12.7w LED,RAL9003 white Downlight 1650lm,power consumption:14.9w

atelier 2

cafe

atelier 3

atelier 1

Company:ETAP LED LP,Surface mounted Diffuser 1550lm,power concumtion=12.7w white

Electricity plan

Atelier-Ground floor

Artificial lightening 500 lux we need wide angle lightening

WC

Danceroom1

Basement

atelier 4

atelier 2

atelieratelier 33

atelier 1 atelier 1

First Floor

First Floor

Study room-First Floor Lightening without artificial light|90-45lux

Study room-First Floor

Artificial Lightening without artificial light|90-45lux 400 lux we need more pointed light

Artificial 400 lux we need more pointed light

Danceroom1

WC

Groundfloor

atelier 4

Artificial lightening lightening without artificial light |25.6 lux from windows 500 lux we need wide angle lightening

corridor

Terrace

First Floor

Atelier-Ground floor lightening without artificial light |25.6 lux from windows

Storage

Terrace

white

Storage

Danceroom2

atelier 2

Groundfloor

Groundfloor

Danceroom2

Danceroom2

corridor

corridor

Basement

Basement

Sport-Dance Room-Basement Lightening without artificial light|13.8lux

Sport-Dance Room-Basement

Artificial lightening Lightening without artificial light|13.8lux 300lux we need surface mounted not to touch ceiling

Artificial lightening 300lux we need surface mounted not to touch ceiling


Calculations ( Energy & Heatloss) Ground Floor of the church Outdoor Temperature -8 Indoor Temperature 16 8 Area of the church wall 1565,5 1905 Area of the church Roof Area of the church window 575,8 U value of the church wall 1,3 U value of the church Roof 3 U value of the church Window 4,8 A* U Value* (T2-T1) Formula= wall: 32562,4 w 32,56 Roof: 91440,0 w 91,44 Window: 44221,4 w 44,22 Total 168,22

c m2 m2 m2 w/m2k w/m2k w/m2k kw kw kw kw

Heat losses due to infiltrations through doors and windows are negligible q=

Formulas for ventilation heat losses through the tower of church

Total Heat losses

Air flow rate Q C Specific heat of water p Density of water 191,2638

Heat loss through the Crypt Indoor Temperature 20 c Outdoor Temperature 14 c area of wall+floors: 1500 351 U value of wall and floor

Heat loss=

0,718 8555,688 w

Total Heat loss Through the church

Zero Impact Building

Q*C*P*(T2-T1)

All of the calculations were done manualy

6 135

8,56 kw 199,82 kw

1986

q= 0,6 1,2

1

16

=

11,52 kw

Heat loss through Boxes Boxes Ground Floor small Indooor 20 c 12 Outdoor 8c Area of wall 75,5 m2 Area of roof 119,5 m3 Area of floor 119,5 m4 Area of window 104,5 m5 Value of wall 0,29 w/m2k Value of roof 0,28 w/m2k Value of floor 0,29 w/m2k Value of Window 1,1 w/m2k wall: 262,74 w roof: 401,52 w Floor: 415,86 w Window: 1379,4 w Total 2459,52 w 2,45952 kw Boxes Ground Floor Big Indooor 20 c Outdoor 8c 12 Area of wall 82 m2 Area of roof 166 m3 Area of floor 166 m4 Area of window 104,5 m5 Value of wall 0,29 w/m2k Value of roof 0,28 w/m2k Value of floor 0,29 w/m2k Value of Window 1,1 w/m2k wall: 285,36 w roof: 557,76 w Floor: 577,68 w Window: 1379,4 w Total 2800,2 w 2,8002 Boxes First Floor Indooor 20 c Outdoor 8c Area of wall 42 Area of window 167 Value of wall 0,29 Value of Window 1,1

12 m2 m2 w/m2k w/m2k

KULeuven . 2016


Floor: Window: Total

577,68 w 1379,4 w 2800,2 w

2,8002

Boxes First Floor Indooor 20 c Outdoor 8c Area of wall 42 Area of window 167 Value of wall 0,29 Value of Window 1,1 wall: 146,16 w Window: 2204,4 w Total 2350,56 w

12 m2 m2 w/m2k w/m2k

2,35056

4,70112 kw

Value calculation for opaque part of the wall Formula:

Zero Impact Building

1/R+R+R Opaque

0,29

All of the calculations were done manualy

KULeuven . 2016


Energy Production Of the Building A: r: H: pr:

total solar panel area Solar panel yeald annual average solar radiation on tilted panles performance Ratio

E=

A*r*H*pr

952,5 15% 750 0,75 80367,19 6697,266 223,2422 9,301758

m2 kwh/m2 an kwh per year kwh per month kwh per day kwh per hour

Production of GYM equipments Treatmiles Bikes Crosstrainers Avarage production 2880 hours 240 hours 8 hours 1 hour

24 17 8

49 100 w 14112 kw per year 1176 kw per month 39,2 kw per day 4,9 kw per hour

Production of wind Turbine (trees) production per tree per year

11500,0 958,3 31,9 1,3

num of trees

kwh per year kwh per month kwh per day

9

kwh per hour

103500 8625 287,5 11,97917

Production of solar collectors

kwh per year kwh per month

kwh per day kwh per hour

num of sollar collectors

annual energy production per solar collector

1172,0 97,7 3,3 0,1

kwh per year kwh per month

kwh per day kwh per hour

14

16408,0 1367,3 45,6 1,9

kwh per year kwh per month

kwh per day kwh per hour

Total Energy production

Zero Impact Building

214387,2 17865,6 595,5 28,1 All of the calculations were done manualy

kwh per year kwh per month kwh per day kwh per hour

KULeuven . 2016


Energy Consumption for the building Appliance

number Power Usage (W) Daily time

Coffee machine Laptop Oven Dishwasher Toaster Blender Refrigrator Display case Ice machine Camputer/cassa Fan to dry hands Coffee pot Microwave Waffle iron Hot plate Vaccum Frying pan Printer Stereo Phone charging Hair dryer Water heater ventilator fan Electric bikes

Type one Type one

Outdoor

Zero Impact Building

2 87 1 1 2 2 2 2 1 1 6 2 1 1 2 2 4 2 1 30 6 1 6 13

800 35 3000 1350 1150 300 500 500 440 25 900 200 1050 1200 1200 450 1200 100 20 10 1000 479 30 360 Total

Lighting Consumption per day 5 in. and 6 in. white trim tecessed retrofit LRD 90CRI 2700k philips T8 LED Florescent tube (12 cm)

watts

298

14

Daily time 10

0,14 euro/ Kwh

Lomeus

14

850

20

1600

cree edge high output ft true white 267-831 technology

power usage All of the calculations werenum done manualy Type 1

5,5 7 3 7 5,5 5,5 24 24 24 8 5 6,5 3 5 5,5 1,5 6 6 2 1,5 6 5 10 20

Used energy Energy Total (wh) Costs for one Day used(kwh) 4400 8800 8,8 1,23 245 21315 21,315 2,98 9000 9000 9 1,26 9450 9450 9,45 1,32 6325 12650 12,65 1,77 1650 3300 3,3 0,46 12000 24000 24 3,36 12000 24000 24 3,36 10560 10560 10,56 1,48 200 200 0,2 0,03 4500 27000 27 3,78 1300 2600 2,6 0,36 3150 3150 3,15 0,44 6000 6000 6 0,84 6600 13200 13,2 1,85 675 1350 1,35 0,19 7200 28800 28,8 4,03 600 1200 1,2 0,17 40 40 0,04 0,01 15 450 0,45 0,06 6000 36000 36 5,04 2395 2395 2,395 0,34 300 1800 1,8 0,25 7200 93600 93,6 13,10 340,86 47,72

up to 63711

Energy used

For 1

140

For all

41720

Energy used

For 1

0,14

For all

41,72

Cost 5,84

0.14 E per kwh KULeuven . 2016


Outdoor

cree edge high output ft true white 267-831 technology num

Type 1 Type 2 Ourdoor

power usage

298 55 10

Energy used

Daily time

14 20 550 Total

up to 63711

For 1

10 10 10

140 200 5500

Water heating energy consumption Total L to be heated for Bathrooms

Q= m C T2-T1 Q

For all

41720 11000 55000

72,22 1733,33 52000 624000

m*c*(T2-T1) Liters of Water specific heat of water Temp difference of cold to hot water energy gained or lost by a substance

3600

72 4,18 30 9028,8 2,508 2,508 60,192 1805,76 21669,12

Geothermal Systen Consumpption 8 Geothermal Heat Exchanger Unit per hour 8 per day 192 per month 5760 per year 69120 circular duct fan air flow rate power

kd-500m3

per hour per day Zero Impact Building

All of the calculations were done manualy

Energy used

For 1

0,14 0,2 5,5

For all

Cost

41,72 11 55 107,72

0.14 E per kwh

5,84 1,54 7,70 15,08

kwh per hour kwh per day kwh per month kwh per year

L j/g.c

4180 J/kc

kl For every hour kwh per hour kwh per day kwh per month kwh per year

w w w w w

2,18 m3/s 1243 kw 1,24 kwh 29,76 kwh KULeuven . 2016


Calculations rainwater 50 l/m2 Roof

Outdoor Temperature -8 Indoor Temperature 8 16 Area of Church wall 1565,5 m2 area of church Floor 1905 m2 Area of church Windows 575,8 m2 Value of Church Wall 1,3 w/m2k Value of church Roof 1,6 w/m2k Value of window 2,4 w/m2k A* u value* (T2-T1) Formula wall 32562,4 Roof 48768 Windows 22110,72 103441,1 103,4411

23,9 573,6 17208 206496

reduced by 1/3! q= q=

Q*C*p*(T2-T1) 11,52

kwh per hour kwh per day kwh per month kwh per year

crypt

Ground Floor number of users: 40 Proved useful consumption: 24000 l/maand

Total proved beneficial 180000consumption: l/maand

Functie WC Was Tuin cleaning

4,42 w/m2k

Total heat absorbed & released later at nights By wall 69239,3

utilization Utilization ( l / day / user) 30 17 4 4

Frequency Gebouwtype Frequentie (Dagen/maand) Crypt 20 Ground Floor 20 Second Floor 20 According opening days

per hour per day per month per year

Ventilation Heat loss to outside=

All of the calculations were done manualy

10000 l 74000 l

Second Floor number of users: 120 Proved useful consumption: 72000 l/maand

Solar Gain Calculations Annual Gains 360 kwh/m2 Total Area of church windows 575,8 Solar Gain 207288 kwh 207,288 4974,912 149247,4 1790968

Zero Impact Building

15

number of users: 140 Proved useful consumption: 84000 l/maand

Cooling during summer

Amittance Value

Total toilets:

Each Tank pond

Shows being useful consumption = utilization x users x frequency

114,9611

Total Heat losses of the Building Heat losses of Crypt+Boxes

1.905 m2

Calculated rain 96000 waterl tank: Additional tank 84000 (min.): l

Ventilation heat losses through the tower of church

Total

Surface roof:

Calculations Hot water demand

11,52 kw 50% of heat gains are expelled *See Excel file for Calculation

Number of Sinks Number of Showers Frequency Number of users per day

Total:

1 7 20 per month 240 per year 160 140

usage Liter per person 2 18

52000 Litrs per month

40

KULeuven . 2016


Calculations ( Ventilation & Heating) Extraction-pulsion crypt

Dance room 1

Dance room 2

Dance room 3

Natural ventilation ducts

Area [m2]

66% 33%

66% 33%

75% 50% 25%

gym 83% 66,40% 49,80% 33,33% 16,60%

Volume [m3]

Ocupation [People]

Q = 60 * Cd * A * sqrt(2 * g * (Hn - Hb) * ((Ti - To) / Ti))

11300%

339

28,25

154

462

38,5

138

414

Top boxes:Ateliers with low movement activities

34,5

Ground boxes:Ateliers with high movement activities

Area [m2] Volume [m3] Ocupation [People] 483 1449 45

box Box 1 top Box 2 top Box 1 ground Box 1 ground

Air flow (cfm) 175 175 280 280

Ti 64.4=18 64.4 64.4 64.4

To 42.8=6 42.8 42.8 42.8

Delta H 49.2 49.2 54.1 54.1

AREA ft2 0.4ft2=>0.19*0.19m 0.4ft2=>0.19*0.19m 0.6ft2=>0.23*0.23m 0.6ft2=>0.23*0.23m

Cafeteria Studyroom

315 225

69.8=21 69.8

42.8 42.8

49 49

0.62ft2=0.78*0.78=>0.23*0.23m

Box Box 1-2 top Box 1-2 ground Cafeteria studyroom

Extraction TOILET AND SHOWER

Q = flow rate in cfm, Cd = 0.65 (for unobstructed openings), A = opening area, square feet, Ti = indoor temp (Rankine), To = outdoor temp (Rankine), Hn = height of "neutral pressure point" (for simple systems, assume 1/2 way between top and bottom openings). Hb = height of bottom opening g = gravity.

Area [m2]

2 =1.4*1.4ft=>0.42*0.42m 0.5ft2=0.20m*0.2m

Number of people 35+35 35+35 45 45

Volume [m3] Ocupation [People] 96 10

32

machine TOILET AND SHOWER

Area [m2]

Volume [m3] Ocupation [People] 32 96 10

CALCULATIONS ARE IN ENGLISH SYSTEM AND LAST RESULTS CONVERTED TO METRIC SYSTEM

90% heat recovery happens

DeLTA T =indoor -outdoor temprature difference L=air flow

Q=heat exchange rate through natural ventilation

CAFETERIA

Q= heat

STUDY ROOM Hall [+2] 100,0%

Q= heat

Ateliers*4

Q= heat

100

100,0%

Zero Impact Building

T (h) 2,6

T® 40

T (h) 2,6

T® 40

T (h) 2,35

All of the calculations were done manualy

L=air flow

L=air flow

3

v

18 0,098484848 T®

40

L=air flow v 21 0,114035088

3 v

18 0,089015152

3

total=0.28

3

box 1 and 2 on top Q 378 L 175 DELTA T 2 box 1 on ground Q 604,8 L 280 DELTA T 2 cafeteria Q 680,4 L 315 Delta T 2 studyroom Q 486 L 225 DELTA T 2

0.11kw

0.17kw

0.19kw

0.14kw

KULeuven . 2016


Calculations ( Lighting) room area Atelier 1 Atelier 2 Atelier 3 Atelier4 study room café Gym Daceroom1 Dnceroom2 Danceroom3 corridor

Zero Impact Building

163 113 79 79 132 132 450 95 123 133 170

lux

300 300 300 300 300 100 300 300 300 300 50

luminaire N plug 2500 19,56 2500 13,56 2500 9,48 2500 9,48 2500 15,84 2000 6,6 2500 54 2500 11,4 2500 14,76 2500 15,96 1650 5,151515

All of the calculations were done manualy

6 5 5 5 10 7 10 3 3 3 2

switch

2 2 1 1 2 2 4 1 1 1 1

THE SPACES THAT ARE NOT CALCULATED ALREADY HAVE LIGHTS

KULeuven . 2016


REFERANCES BOOKS **Hand book of sustainable building , An enviromentaly preference method for selection of materails for use in construction and refurbishment, David Anink , Chiel Boonstra , John Mak , James & James Science Publishers, 1996 **Metarials Structures Standards , Julia Mcmorrough, Rockport Publisher , 2006 ** Building Simply two , Sustainable cost – efficient Local, Christian Schittich , Detail , 2012 ** ASHRAE PRINCIPLES ** HVAC Principles and Applications Manual Mull, Thomas E. , MC Graw – Hill Publisher ** Advanced Strategy Guideline: Air Distribution Basics and Duct Design Arlan Burdick IBACOS, Inc. ** HANDBOOK OF AIR CONDITIONING AND REFRIGERATION writer:shan.k wang BASIC INFORMATIONS http://www.sunearthtools.com/dp/tools/pos_sun.php https://www.windfinder.com/ http://www.meteo-info.be/en/europe/belgium/weather-brussels/details/N2728206-/ ENERGY http://www.flanderstoday.eu/innovation/vito-drills-deep-under-flemish-soil-tap-geothermal-energy http://www.solarlec.be/zonnepanelen/zonnepanelen-types http://www.concretecentre.com/ http://www.iea.org/ http://pvwatts.nrel.gov/pvwatts.php https://www.systemair.com/en-GB/UK LIGHTENING http://www.etaplighting.com/ http://solarelectricityhandbook.com/solar-angle-calculator.html https://www.youtube.com/user/TheDIALux?gl=BE VENTILATION AND HEATING http://www.engineeringtoolbox.com/air-heating-systems-d_1136.html http://sustainabilityworkshop.autodesk.com/buildings/stack-ventilation-and-bernoullis-principle http://www.livingwithavent.com/pages.aspx?page=Basics/What http://www.engineeringtoolbox.com/sizing-ducts-d_207.html Zero Impact Building

KULeuven . 2016


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.