Rula Hasan, Construction Document Set

Page 1

PRODUCED BY AN AUTODESK STUDENT PRODUCT

INTERIOR DESIGN GENERAL PROJECT NOTES

PROJECT DATE

1. THE CONTRACT DOCUMENTS ARE THE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT.

PROJECT DESCRIPTION:

2. “INSTALL” MEANS SUPPLIED BY OTHERS, TO BE INSTALLED BY CONTRACTOR.

BURRUSS OPEN OFFICE ADDITION

THIS PROJECT IS A PARTIAL RENOVATION TO THE SECOND FLOOR AT THE NORTH SIDE OF BURRUSS HALL. THERE IS NO CHANGE OF USE, INCREASE IN AREA, OR ACTIVITY FUNCTIONS. APPLICABLE CODES AND REFERENCE STANDARDS:

3. “PROVIDE” MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) NATIONAL ELECTRIC CODE (NEC) AMERICANS WITH DISABILITIES ACT (ADA)

4. “TYPICAL” MEANS IDENTICAL FOR CONDITIONS NOTED. 5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. VERIFY DIMENSIONS WITH FIELD CONDITIONS, IF DISCREPANCIES ARE DISCOVERED BETWEEN FIELD CONDITIONS AND DRAWINGS OR BETWEEN INDIVIDUAL DRAWINGS, CONTACT THE DESIGNER FOR RESOLUTION BEFORE PROCEEDING.

USE GROUP CLASSIFICATION (EXISTING SPACE):

VIRGINIA TECH

E (EDUCATION) A (ASSEMBLY)

6. HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FINISHED FACE OF CONSTRUCTION, EXCEPT WHEN NOTED AS CENTERLINE (CL), DIMENSIONS ARE TO CENTERLINE OF FRAMING.

USE GROUP CLASSIFICATION (PROPOSED SPACE): A (ASSEMBLY) * NOTE: THERE IS NO CHANGE OF USE.

7. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB, EXCEPT WHERE NOTED TO BE FROM ABOVE FINISHED FLOOR, (A.F.F.).

CONSTRUCTION TYPE: 2A NON-COMBUSTIBLE, PROTECTED

8. CUT AND FIT COMPONENTS FOR ALTERATION OF EXISTING WORK AND INSTALLATION OF NEW WORK. PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES.

OCCUPANT LOADS:

9. PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING PERFORMANCE OF THE WORK. FIREPROOF NEW PENETRATIONS REQUIRED BY THE WORK AND EXISTING PENETRATIONS IN EXPOSED PLENUM AREAS. 10. CONTRACTOR & SUB-CONTRACTORS SHALL COORDINATE THE LAYOUT AND EXACT LOCATIONS OF ALL PARTITIONS, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SWITCHES WITH DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION.

EDUCATION AREAS CALCULATED AT ASSEMBLY AREAS CALCULATED AT

ISSUED FOR:

DATE:

20 SQ.FT. PER OCCUPANT 15 SQ.FT. PER OCCUPANT

OCCUPANT LOAD: PROPOSED SPACE, SECOND FLOOR:

CODE: 482 ACTUAL: 130

PROJECT SQUARE FOOTAGE: PROPOSED SPACE, SECOND FLOOR:

9,550 NET SQ.FT.

PRODUCED BY AN AUTODESK STUDENT PRODUCT

12. CONTRACTOR TO FOLLOW MANUFACTURER’S RECOMMENDED SPECIFICATIONS AND INSTALLATION PROCEDURES. IF THESE ARE CONTRARY TO THE CONTRACT DOCUMENTS, CONTRACTOR SHALL NOTIFY THE DESIGNER, IN WRITING IMMEDIATELY, TO RESOLVE DISCREPANCIES PRIOR TO PROCEEDING. 13. CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE, CONTRACTOR SHALL NOTIFY DESIGNER IMMEDIATELY TO ALLOW DESIGNER A REASONABLE AMOUNT OF TIME TO SELECT A REASONABLE SUBSTITUTE. 14. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS, OR DISCOLORATION. JOINTING SHALL BE TIGHT FITTING, NEAT AND WELL SCRIBED. THE FINISH WORK SHALL NOT HAVE EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS. ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. 15. CONTRACTOR SHALL COMPLY WITH ALL BASE BUILDING REQUIREMENTS AND DESIGN CRITERIA. 16. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL COMPLY. REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO THE CURRENT APPLICABLE EDITIONS OR PUBLICATIONS OF THE FOLLOWING (OR OTHERWISE NOTED): A. INTERNATIONAL BUILDING CODE (IBC 2012 EDITION) B. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) C. NATIONAL ELECTRIC CODE (NEC) D. INTERNATIONAL PLUMBING CODE (IPC 2009 EDITION) E. INTERNATIONAL MECHANICAL CODE (IMC 2009 EDITION) F. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) G. AMERICANS WITH DISABILITIES ACT (ADA) H. LOCAL MUNICIPAL ORDINANCES AND AMENDMENTS TO THE CODES

SHEET INDEX SHEET #

SHEET NAME

A100

COVER SHEET

A101 A102

FIRE & LIFE SAFETY PLAN EXISTING PLAN

A103

DEMOLITION PLAN

A104

PLAN

A105

ENLARGED PLAN

A106

INTERIOR SECTIONS

A107

WALL SECTIONS

A108

INTERIOR ELEVATIONS

A109

INTERIOR WALL DETAILS

A110

MILLWORK DETAILS

A111

FINISH PLAN

A112

FURNITURE PLAN

A113

POWER & DATA PLAN

A114

RCP

A115

ENLARGED RCP

DATE

07 MAY, 2013

PROJECT NUMBER 2013_0001 DRAWN BY

RULA HASAN

CHECKED BY

RULA HASAN

COVER SHEET

SITE PLAN

BURRUSS HALL, ROOM 224A

PROJECT NORTH

VICINITY MAP

TRUE NORTH PROJECT NORTH

VIRGINIA TECH, BLACKSBURG

A100

PRODUCED BY AN AUTODESK STUDENT PRODUCT

PRODUCED BY AN AUTODESK STUDENT PRODUCT

11. CONTRACTOR SHALL PROVIDE MANUFACTURER’S SPECIFICATIONS, INSTALLATION INSTRUCTIONS, SHOP DRAWINGS AND SAMPLES FOR REVIEW AND APPROVAL OF ALL MATERIALS AND METHODS TO BE USED PRIOR TO ORDERING OR PROCEEDING WITH THE WORK.