TL-CC1 The Rotronic cold-chain temperature logger TL-CC1 is easy to configure (without software), generates PDF reports automatically and comes at an unbeatable price. APPLICATIONS Monitoring of the cold chain during the transportation of sensitive freight such as pharmaceuticals, foods and technical products. FEATURES • PDF report generation without software installation • Freely configurable • Clear alarm indication • All-in-one logger: configuration tool, PDF report, instruction manual and calibration certificate • High storage capacity, single use, single journey • Conforms to GxP, EN 12830 and FDA 21 Part 11 / GAMP 5 Technical data
TL-CC1
PDF report
General Parameter Temperature sensor Accuracy at -30...70 °C Resolution Range of application / Storage conditions IP protection Weight Battery Dimensions without bag Dimensions with bag Logging interval Start delay Alarm ranges Alarm type Storage period Storage capacity Event marking Use Alarm indication Communication Operating system Conformity
Temperature NTC thermistor ±0.5 K 0.1 °C -30...70 °C / -22...158 °F, < 80 %RH IP65 (in plastic bag) Approx. 10 g CR2032 (not replaceable) 80 x 43 x 2.5 mm 105 x 55 x 2.5 mm 0.5/5/10/30/60/90/120 min. 0.5/5/10/30/60/90/120 min. -20…-10 °C, -10…0 °C, 2…8 °C, 0…15 °C, 0…25 °C, 15…25 °C, freely selectable values Deactivated, single or cumulative 12 months 8192 data points Up to 8 points START/STOP button, MARK button LED indicators PDF reports USB 2.0 port, type A Windows GxP, EN 12830, FDA 21 CFR Part 11 and GAMP5
Delivery package • 10 pc. per box • Short instruction manual